Crestron.SimplSharpPro.Thermostats Namespace

 
Classes
 ClassDescription
Public classBasalteDeseo Basalate deseo thermostat class.
Public classBasalteDeseoEventIds Event ids used by BasalteDeseo.
Public classBatteryEventArgs Event arguments to detail battery state.
Public classChvThstat Class used for CHV-THSTAT thermostats. The CHV-THSTAT is a programmable thermostat that provides both temperature and humidity control.
Public classChvTstat Class used for CHV-TSTAT thermostats. The CHV-TSTAT is a programmable thermostat that provides both temperature and humidity control.
Public classCode exampleChvTstatex Class used for CHV-TSTATEX thermostats. The CHV-TSTATEX is a wireless thermostat featuring infiNET EX® technology.
Public classChvTstatexFcu Class used for CHV-TSTATEX-FCU thermostats. The CHV-TSTATEX-FCU is a wireless thermostat featuring infiNET EX® technology.
Public classCode exampleChvTstatFcu A versatile heating and cooling thermostat for fan coil unit (FCU) HVAC systems.

This class will trigger BaseEvent, FanCallChange, HumidityEvent, and ClimateControlComponentCallChangeHandler events.

Public classChvTstatFcuHotelPir10 CHV-TSTAT-FCU-HOTEL-PIR-10 device class.

This class will trigger CustomerControlsPropertyChange, HotelControlsPropertyChange, SettingsPropertyChange and SystemStatusPropertyChange events.

Public classChvTstatFcuHotelPir10Base Base class for ChvTstatFcuHotelPir10 and ChvTstatFcuHotelPir10WT

This class will trigger CustomerControlsPropertyChange, HotelControlsPropertyChange, SettingsPropertyChange and SystemStatusPropertyChange events.

Public classChvTstatFcuHotelPir10BookedVacantSettings Booked Vacant settings class.

This class will trigger SettingsPropertyChange and SystemModeSetpointChange events.

Public classChvTstatFcuHotelPir10CustomerControls Customer controls class.

This class will trigger CustomerControlsPropertyChange and SystemModeSetpointChange events.

Public classChvTstatFcuHotelPir10EventIds Event ids for ChvTstatFcuHotelPir10 and ChvTstatFcuHotelPir10WT device classes.
Public classChvTstatFcuHotelPir10HotelControls Hotel controls class.

This class will trigger HotelControlsPropertyChange and SystemModeSetpointChange events..

Public classChvTstatFcuHotelPir10Settings Settings base class for ChvTstatFcuHotelPir10BookedVacantSettings, ChvTstatFcuHotelPir10UnbookedOccupiedSettings and ChvTstatFcuHotelPir10UnbookedVacantSettings.

This class will trigger SettingsPropertyChange and SystemModeSetpointChange events.

Public classChvTstatFcuHotelPir10SystemStatus System Status class.

This class will trigger SystemStatusPropertyChange

Public classChvTstatFcuHotelPir10UnbookedOccupiedSettings Unbooked occupied settings class.

This class will trigger SettingsPropertyChange and SystemModeSetpointChange events.

Public classChvTstatFcuHotelPir10UnbookedVacantSettings Unbooked vacant settings class.

This class will trigger SettingsPropertyChange and SystemModeSetpointChange events.

Public classChvTstatFcuHotelPir10WT CHV-TSTAT-FCU-HOTEL-PIR-10-W-T device class.

This class will trigger CustomerControlsPropertyChange, HotelControlsPropertyChange, SettingsPropertyChange, SystemStatusPropertyChange and MiscellaneousPropertyChange events.

Public classClimateControlCallEventArgs Event arguments to return the climate control component that changed.
Public classClimateControlComponent Class that is used to to represent each climate control component and its state.
Public classCresnetThermostat Base class for Cresnet thermostats.
Public classCode exampleDin1Tstat8 8 Channel Radiant Heat Thermostat.

This class will trigger BaseEvent event.

Public classDin1Tstat8Din1Tstat8ControlChannel Control Channel class for DIN-1TSTAT8.

This class will trigger BaseEvent event.

Public classCode exampleDinThstat Cresnet Thermostat with two parts, first part is DIN Head Unit which is installed at the HVAC unit and the second part is UI and may also contain one Temperature Sensor where is it not possible to land the sensors directly on the head unit. The login on how to control HVAC is contained in the head unit.

This class will trigger BaseEvent, HumidityEvent, FanCallChangeClimateControlComponentCallChange and TemperatureChange events.

Public classDinThstatDinThstatSchedulerOperation Scheduler Operation class.

This class will trigger BaseEvent event.

Public classCode exampleDinTstatFcu A universal fan coil controller designed for use in two-pipe applications. It includes the versatility to allow the device to be used in various types of applications.

This class will trigger BaseEvent, StateChange events.

Public classFanCallEventArgs Event arguments to detail what changed on a fan when state information was received.
Public classFanMode Fan modes class, represents the current fan mode.
Public classHumidityEventArgs Event arguments to detail what
Public classHumidityThermostat Class used for the humidity thermostat component of thermostats.
Public classHzThstat HZ-THSTAT device class.
Public classHzThstatUiStatusReservedSigs Extender class to provide access to UI Reserved Sigs feature of the HZ-THSTAT class.

This class will trigger DeviceExtenderSigChange event.

Public classRFThermostat Base class for Crestron radio frequency thermostats.
Public classScheduledSetpoints Class used for the scheduled setpoints of a thermostat.
Public classSingleSpeedFan Base class for single speed fan thermostat devices.
Public classSystemModeSetpoint System mode setpoint class, represents the set point vlaues for heat, cool and auto modes.
Public classTemperatureEventArgs Event arguments to detail temperature changes when state information is received.
Public classTemperatureFormat Temperature format class, represents the current display format for temperature supported by the system.
Public classThermostat Base class for Crestron thermostats.
Public classThermostatMode Thermostat Mode class. Represents the current mode of thermostat. supported modes are heat, cool, auto modes.
Public classThermostatSystemModeSetpointEventArgs Event arguments class used for "SystemModeSetpointChange" event in the thermostat device.
Interfaces
 InterfaceDescription
Public interfaceIBatteryDevice Interface for devices that have a battery.
Delegates
 DelegateDescription
Public delegateBatteryChangeHandler Delegate definition for the battery event handler.
Public delegateClimateControlComponentCallChangeHandler Delegate definition for the climate control component change event handler.
Public delegateFanCallChangeHandler Delegate definition for the fan change event handler.
Public delegateHumidityChangeHandler Delegate definition for the humidity event handler.
Public delegateTemperatureChangeHandler Delegate definition for the temperature change event handler.
Public delegateThermostatSystemModeSetpointEventHandler Delegate to define the event handler for SystemModeSetpoint.
Enumerations
 EnumerationDescription
Public enumerationDinThstatDinThstatSchedulerOperationeScheduleMode Enum to define the Schedule Modes.
Public enumerationDinThstatDinThstatSchedulerOperationeWeekDay Enum to define the week days used for scheduling the events.
Protected enumerationDinThstateThermostatType Enum values for all thermostats derived of DIN-THSTAT.
Public enumerationDinThstateUiLanguage Enum to define the Languages used on the HZ-THSTAT UI.
Public enumerationeBatteryState Enumeration to define the states of a thermostat battery.
Public enumerationeClimateControlComponentState Enumeration that defines the different states that each climate control component can be in.
Public enumerationeClimateControlComponentType Enumeration that defines the different climate control components.
Public enumerationeDinThstatFanMode Enumeration to define the fan modes of a DIN-THSTAT thermostat.
Public enumerationeFanMode Enumeration to define the fan modes of an RF thermostat.
Public enumerationeFanSpeed Enumeration that defines the various speeds for the fan. If fan has only one speed then High or Inactive will be returned.
Public enumerationeFanState Enumeration that describes whether the fan is on or off or circulating.
Public enumerationeFloorWarmingMode Enum to define Floor Warming modes.
Public enumerationeHoldMode Enumeration to define the hold modes of an RF thermostat.
Public enumerationeHumidifierMode Enum to define Humidifier modes.
Public enumerationeHumidityType Enumeration that defines the humidity types.
Public enumerationePressType Enum for touch press types.
Public enumerationeSchedulerMode Enumeration to define the modes of DIN-THSTAT thermostat scheduler.
Public enumerationeSystemMode Enumeration to define the system modes of an RF thermostat.
Public enumerationeTemperatureFormat Enumeration to define the different temperature formats that can be displayed.
Public enumerationeTemperatureType Enumeration that defines the temperature types.
Public enumerationHzThstateFcuSystemTypes Enumeration to define the supported fan speeds of a FCU system
Public enumerationHzThstateHzThstatFanSpeed Enumeration to define the fan speed of a HZ-THSTAT thermostat