Click or drag to resize

BasalteDeseo Class

Basalate deseo thermostat class.
Inheritance Hierarchy
SystemObject
  Crestron.SimplSharpProGenericBase
    Crestron.SimplSharpProGenericDevice
      Crestron.SimplSharpPro.ThermostatsBasalteDeseo

Namespace: Crestron.SimplSharpPro.Thermostats
Assembly: Crestron.SimplSharpPro.Thermostats (in Crestron.SimplSharpPro.Thermostats.dll) Version: 2.21.121
Syntax
C#
public sealed class BasalteDeseo : GenericDevice

The BasalteDeseo type exposes the following members.

Constructors
 NameDescription
Public methodBasalteDeseo(UInt32, CrestronControlSystem) Constructor used to add the Basalte Deseo to a control system.
Public methodBasalteDeseo(UInt32, IDeviceBranch) Constructor used to add the Basalte Deseo to a cresnet branch.
Top
Properties
 NameDescription
Public propertyClock Property to set the time. Value set here can be seen on display. Time format can be 12h or 24h, as per Basalte Deseo Configuration TimeFormat parameter..
Public propertyConfiguration Property to set the configuration for Basalte deseo.
Public propertyConnectedIpList A property containing the list of the ConnectedIpInformation objects which contain information about the devices that are connected to this IP ID. This property is only valid for an ethernet device. If this is not an ethernet device, then this property will return null. If this is an ethernet device, the list will be non-null. It will be empty if no devices are connected. The order of items in this list is not guaranteed.
(Inherited from GenericDevice)
Public propertyCode exampleDescription Get/Set the description of this device.
(Inherited from GenericBase)
Public propertyDisposed Property to indicate if the device has been disposed.
(Inherited from GenericDevice)
Public propertyExternalHumidity Property to set the relative humidity from an external sensor. If enabled in the ‘Basalte Deseo Configuration’ module the humidity can be displayed on the start screen of the Deseo. This value is ignored if the internal sensor is used.
Public propertyExternalTemperature Property to set the room temperature from an external sensor. If enabled in the ‘Basalte Deseo Configuration’ module the temperature can be displayed on the start screen of the Deseo. This value is ignored if the internal sensor is used.
Public propertyFanMode Property to set the Fan Mode.
Public propertyFanModeFeedback Property indicates the current fan mode.

The BaseEvent will trigger with FanModeFeedbackEventId for this property.

Public propertyHumidityFeedback Property indicates the relative humidity in following format xx.x. This will be updated for every 60 seconds, or on change of 1% Humidity, based on the Basalte Deseo Configuration.

The BaseEvent will trigger with HumidityFeedbackEventId for this property.

Public propertyID Property to get the ID of the device.
(Inherited from GenericDevice)
Public propertyInternalHumidityFeedback Property indicates the relative humidity of the built-in humidity sensor in whole numbers.

The BaseEvent will trigger with InternalHumidityFeedbackEventId for this property.

Public propertyInternalTemperatureFeedback Property indicates the ambient room temperature in tenths of a degree Celsius or Fahrenheit. The temperature will be updated every 60 seconds, or on every temperature change of 0.5 Celsius. (equal to 0.9 Fahrenheit).

The BaseEvent will trigger with InternalTemperatureFeedbackEventId for this property.

Public propertyIsCooling Property indicates that the system is cooling. true = Cool running, false = System not running.
Public propertyIsHeating Property indicates that the system is heating. true = Heat running; false = System not running
Public propertyIsOnline Property to get the current online state of the device.
(Inherited from GenericDevice)
Public propertyMaximumSetpoint Property returns SystemModeSetpoint object. Property to set the maximum setpoints allowed to display and report by the Deseo. Reported in tenths of a degree. Maximum analog values are as follows: Heat setpoint: 890 (89 F) or 320 (32 C). Cool setpoint: 990 (99 F) or 370 (37 C).
Public propertyMessage Property to set text string. Value set here can be seen on display.
Public propertyMinimumSetpoint Property returns SystemModeSetpoint object. Property to set the minimum setpoints allowed to display and report by the Deseo. Minimum analog values are as follows: Heat setpoint: 380 (38 F) or 30 (3 C). Cool setpoint: 590 (59 F) or 150 (15 C). Reported in tenths of a degree.
Public propertyMultiTouchLongPressMessage Property to set text label,if the MultiTouchPressTypeFeedback is set to LongPress.
Public propertyMultiTouchPressTypeFeedback Property indicates the current Multi Touch Press type.

The BaseEvent will trigger with MultiTouchPressTypeFeedbackEventId for this property.

Public propertyMultiTouchShortPressMessage Property to set text label,if the MultiTouchPressTypeFeedback is set to ShortPress.
Public propertyName Get the name of this device.
(Inherited from GenericBase)
Public propertyParent The parent that a given object was added to.
(Inherited from GenericBase)
Public propertyRegisterable Property to indicate that this device can be registered.
(Inherited from GenericDevice)
Public propertyRegistered Property to get the current registration state of the device.
(Inherited from GenericDevice)
Public propertyRegistrationFailureReason Property to get the Registration Failure Reason, this will match the return value from the call to register.
(Inherited from GenericDevice)
Public propertySetpoint Property returns SystemModeSetpoint object. Represents heat, cool and auto setpoint temperatures for display. In case of auto mode is enabled, it is advised to use single/auto setpoint mode. Reported in tenths of a degree.

The SystemModeSetpointChange event will trigger with HeatSetpointFeedbackEventId, CoolSetpointFeedbackEventId and AutoSetpointFeedbackEventId for this property.

Protected propertySIMPLDeviceImplementation Internal protected member used for actual device control.
(Inherited from GenericDevice)
Public propertyStatusFeedback Property indicates the keypads software version after a power cycle. If an invalid string is received on the Configuration input, an error message will be displayed on this output.

The BaseEvent will trigger with StatusFeedbackEventId for this property.

Public propertySystemMode Property to set the system mode.
Public propertySystemModeFeedback Property indicates the current system mode.

The BaseEvent will trigger with SystemModeFeedbackEventId for this property.

Public propertyTemperatureFeedback Property indicates the ambient room temperature in following format xx.x. The temperature format and report type can be set using the Basalte Deseo Configuration module. The temperature will be updated every 60 seconds, or on every temperature change of 0.5 Celsius. (equal to 0.9 Fahrenheit).

The BaseEvent will trigger with TemperatureFeedbackEventId for this property.

Public propertyType Property to determine to type of device this is.
(Inherited from GenericDevice)
Public propertyUnRegistrationFailureReason Property to get the Unregistration Failure Reason, this will match the return value from the call to unregister.
(Inherited from GenericDevice)
Public propertyUserSpecifiedObject Can be assigned anything that user wants.
(Inherited from GenericBase)
Protected propertyXioEndpointStubSIMPLDevice The SIMPL "stub" Device that the XiO Director creates for an endpoint to send the 1C/0E to the correct place in hierarchy.
(Inherited from GenericDevice)
Top
Methods
 NameDescription
Public methodDispose Clean up of resources.
(Inherited from GenericBase)
Protected methodDispose(Boolean) Method to perform the actual disposing of the device.
(Inherited from GenericDevice)
Public methodEqualsDetermines whether the specified object is equal to the current object.
(Inherited from Object)
Protected methodFinalize Destructor of the device.
(Inherited from GenericDevice)
Public methodGetHashCodeServes as the default hash function.
(Inherited from Object)
Public methodGetTypeGets the Type of the current instance.
(Inherited from Object)
Protected methodOnBaseEvent(Int32) Protected member used to fire the BaseEvent with the default extended information.
(Inherited from GenericBase)
Protected methodOnBaseEvent(Int32, UInt16) Protected member used to fine the BaseEvent with extended event information.
(Inherited from GenericBase)
Public methodRegister Register this device with the system.
(Inherited from GenericDevice)
Public methodToString Return the name of the device.
(Inherited from GenericDevice)
Public methodUnRegister Unregister this device with the system. This function can not be called from the device's own SigChange event handler.

On successful unregistration, if this device supports the OnlineStatusChange event, it will trigger indicating the device when offline.


(Inherited from GenericDevice)
Public methodWakeUp Method to wake up the dispaly.
Top
Events
 NameDescription
Public eventBaseEvent Generic base event, triggered when the there are no other handlers available for a specific EventID.
(Inherited from GenericBase)
Public eventIpInformationChange Event that tells what IP Address is connected/disconnected from an IP ID for a non-UDP device. This is only valid for an Ethernet device. An exception will be thrown if it is not.
(Inherited from GenericDevice)
Public eventOnlineStatusChange Event triggered when the Online status of the device changes.
(Inherited from GenericDevice)
Public eventSystemModeSetpointChange Event triggered when a feedback has changed for SystemModeSetpoint.
Top

Version Information

.NET

Supported in: 6.0

.NET Compact Framework

Supported in: 3.5
See Also