Single |
public class SingleSpeedFan : CresnetThermostat
The SingleSpeedFan type exposes the following members.
| Name | Description | |
|---|---|---|
| SingleSpeedFan | Constructor to generate a new SingleSpeedFanThermostat. |
| Name | Description | |
|---|---|---|
| Auto1ptSetpoint |
Sets the auto1pt setpoint, where 1d = 0.1 degrees.
The value is based on the current temperature scale (Fahrenheit or Celsius).
The displayed value is rounded to whole or half degrees based on the setting.
(Inherited from Thermostat) | |
| Auto1ptSetpointFeedback |
Reports the active auto1pt setpoint value.
This output should be connected to the corresponding setpoint input; otherwise the output will not report the setpoint value.
The BaseEvent event will trigger with Auto1ptSetpointFeedbackEventId. (Inherited from Thermostat) | |
| Auto1ptSetpointMinus |
Lowers the temperature regulating setpoint for single-point auto only.
(Inherited from CresnetThermostat) | |
| Auto1ptSetpointPlus |
Raises the temperature regulating setpoint for single-point auto only.
(Inherited from CresnetThermostat) | |
| AutoDeadbandFeedback |
Reports the auto deadband value selected via the "db" option in the Setup menu, where 1d = 0.1 degrees.
In dual-setpoint auto mode, this value is the minimum separation between heat and cool setpoints,
which prevents the system from toggling back and forth due to overshoot.
In single-setpoint auto mode, this value sets the hysteresis used when changing from heat to cool.
For example, if the setpoint is 70°F with auto deadband of 2 degrees,
the temperature would have to rise to 72°F before running cool, and 68°F before running heat.
HZ-THSTAT reports auto mode deadband parameter in 10ths of current unit:
Fahrenheit : 20, 30, 40, 50, 60 (F).
Celsius : 10, 20, 30 (C).
The BaseEvent event will trigger with AutoDeadbandFeedbackEventId. (Inherited from Thermostat) | |
| AUXBalancePoint | Reports the auxiliary balance point in tenths of a degree. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. This property is not supported by ChvTstatFcu Thermostat. | |
| AuxHeatCallFeedbacks | Returns a collection of components that indicate when the system is calling for auxiliary heat. This property is not supported by ChvTstatFcu Thermostat. | |
| ColdWeatherComp |
Indicates that cold weather compensation has been enabled. The output remains true for as long as the mode is enabled.
Outdoor low-temperature compensation modifies the humidifier output to prevent condensation on windows in cold weather.
(Inherited from CresnetThermostat) | |
| ConnectedIpList |
A property containing the list of the ConnectedIpInformation objects which contain information about the devices that are connected to this IP ID.
This property is only valid for an ethernet device. If this is not an ethernet device, then this property will return null.
If this is an ethernet device, the list will be non-null. It will be empty if no devices are connected.
The order of items in this list is not guaranteed.
(Inherited from GenericDevice) | |
| CoolAnticipator |
Reports the cool anticipator values, from 1 to 6. Prevents overshooting the set temperature.
A lower number signifies more frequent cycles and faster response (tighter regulation),
while a higher number signifies less frequent cycles and slower response (looser regulation).
(Inherited from CresnetThermostat) | |
| CoolCallFeedbacks |
Returns a collection of components that indicate when the system is calling for cooling.
The ClimateControlComponentCallChange event will trigger with ClimateControlComponent object. (Inherited from Thermostat) | |
| CoolSetpoint |
Sets the cool setpoint, where 1d = 0.1 degrees.
The value is based on the current temperature scale (Fahrenheit or Celsius).
The displayed value is rounded to whole or half degrees based on the setting.
(Inherited from Thermostat) | |
| CoolSetpointFeedback |
Reports the active cool setpoint value.
This output should be connected to the corresponding setpoint input; otherwise the output will not report the setpoint value.
The BaseEvent event will trigger with CoolSetpointFeedbackEventId. (Inherited from Thermostat) | |
| CoolSetpointMinus |
Lowers the temperature regulating setpoint for cool-only.
(Inherited from CresnetThermostat) | |
| CoolSetpointPlus |
Raises the temperature regulating setpoint for cool-only.
(Inherited from CresnetThermostat) | |
| CoolStages1 | Indicates how many stages of cooling there are in the system. This property is not supported by ChvTstatFcu Thermostat. | |
| CoolStages2 | Indicates how many stages of cooling there are in the system. This property is not supported by ChvTstatFcu Thermostat. | |
| Description |
Get/Set the description of this device.
(Inherited from GenericBase) | |
| DispGlobalPage |
Indicates that the Global page (consisting of the Global Send button) has been enabled for display on the thermostat LCD.
The output remains true for as long as the page is enabled.
(Inherited from CresnetThermostat) | |
| DispHumidityModePage | Indicates that the Humidity Mode page has been enabled for display on the thermostat LCD. The output remains true for as long as the page is enabled. The Humidity Mode page allows the user to enable or disable the humidifier. | |
| DispHumidityViewPage | Indicates that the Humidity View page has been enabled for display on the thermostat LCD. The output remains true for as long as the page is enabled. The Humidity View Page displays the relative humidity and setpoint values. | |
| Disposed |
Property to indicate if the device has been disposed.
(Inherited from GenericDevice) | |
| DispOutdoorPage |
Indicates that the Global page (consisting of the Global Send button) has been enabled for display on the thermostat LCD.
The output remains true for as long as the page is enabled.
(Inherited from CresnetThermostat) | |
| DispRemoteBtnPage1 |
Indicates that Remote page 1 has been enabled for display. The output remains true for as long as the page is enabled.
The thermostats provide two Remote pages that can be used to trigger non-HVAC functions such as AV control, lighting, or alarm activation.
(Inherited from CresnetThermostat) | |
| DispRemoteBtnPage2 |
Indicates that Remote page 2 has been enabled for display. The output remains true for as long as the page is enabled.
The thermostats provide two Remote pages that can be used to trigger non-HVAC functions such as AV control, lighting, or alarm activation.
(Inherited from CresnetThermostat) | |
| DualFuelSubtype | Indicates the current subtype for heating/cooling systems. This property is not supported by ChvTstatFcu Thermostat. | |
| DualSetpointsAutoMode |
Indicates that dual-point auto mode has been enabled. The output remains true for as long as the mode is enabled.
Auto mode can be enabled or disabled from the Setup menu.
(Inherited from CresnetThermostat) | |
| FanAuto |
Sets the fan to auto mode.
In Auto mode, the fan runs only when the system calls.
(Inherited from CresnetThermostat) | |
| FanAutoFeedback |
Reports if the fan is currently in auto mode.
(Inherited from CresnetThermostat) | |
| FanCall | Indicates that the fan is running. This property is not supported by ChvTstatFcu Thermostat. | |
| FanOn |
Sets the fan to on mode.
In On mode, the fan runs continually.
(Inherited from CresnetThermostat) | |
| FanOnFeedback |
Reports if the fan is currently in on mode.
(Inherited from CresnetThermostat) | |
| FloorWarmSysModeHeat | Turns the floor-warming system on. This property is not supported by ChvTstatFcu Thermostat. | |
| FloorWarmSysModeHeatFeedback | Reports the status of the floor-warming system. This property is not supported by ChvTstatFcu Thermostat. | |
| FloorWarmSysModeOff | Turns the floor-warming system off. This property is not supported by ChvTstatFcu Thermostat. | |
| FloorWarmSysModeOffFeedback | Reports the status of the floor-warming system. This property is not supported by ChvTstatFcu Thermostat. | |
| ForceAirSubtype | Indicates the current subtype for heating/cooling systems. This property is not supported by ChvTstatFcu Thermostat. | |
| FrontPanelLockout |
Locks out the four hard pushbuttons on the thermostat for as long as the input remains true.
In this mode, pressing the buttons will have no effect. Automatically disabled in case of system error or failure.
(Inherited from CresnetThermostat) | |
| GlobalPress |
Briefly pulses whenever the Send button of the Global Update page is pressed.
This signal can be tied to logic in the program to trigger functions such as global updates of temperature or humidity values.
(Inherited from CresnetThermostat) | |
| HeatAnticipator |
Reports the heat anticipator values, from 1 to 6. Prevents overshooting the set temperature.
A lower number signifies more frequent cycles and faster response (tighter regulation),
while a higher number signifies less frequent cycles and slower response (looser regulation).
(Inherited from CresnetThermostat) | |
| HeatCallFeedbacks |
Returns a collection of components that indicate when the system is calling for heat.
The ClimateControlComponentCallChange event will trigger with ClimateControlComponent object. (Inherited from Thermostat) | |
| HeatCoolType | Reports the maximum slab temperature value. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. This property is not supported by ChvTstatFcu Thermostat. | |
| HeatPumpType | Indicates the current system type. This property is not supported by ChvTstatFcu Thermostat. | |
| HeatSetpoint |
Sets the heat setpoint, where 1d = 0.1 degrees.
The value is based on the current temperature scale (Fahrenheit or Celsius).
The displayed value is rounded to whole or half degrees based on the setting.
(Inherited from Thermostat) | |
| HeatSetpointFeedback |
Reports the active heat setpoint value.
This output should be connected to the corresponding setpoint input; otherwise the output will not report the setpoint value.
The BaseEvent event will trigger with HeatSetpointFeedbackEventId. (Inherited from Thermostat) | |
| HeatSetpointMinus |
Lowers the temperature regulating setpoint for heat-only.
(Inherited from CresnetThermostat) | |
| HeatSetpointPlus |
Raises the temperature regulating setpoint for heat-only.
(Inherited from CresnetThermostat) | |
| HeatStages1 | Indicates how many stages of heating there are in the system. This property is not supported by ChvTstatFcu Thermostat. | |
| HeatStages2 | Indicates how many stages of heating there are in the system. This property is not supported by ChvTstatFcu Thermostat. | |
| HoldOff |
Turns off the Hold function.
(Inherited from CresnetThermostat) | |
| HoldOn |
Turns on the Hold function.
(Inherited from CresnetThermostat) | |
| HPBalancePoint | Reports the heat pump balance point in tenths of a degree. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. This property is not supported by ChvTstatFcu Thermostat. | |
| HumidifierEnable | Enables the humidifier. | |
| HumidifierEnableFeedback | Indicates that the humidifier is enabled. | |
| HumidifierOff | Turns off the humidifier. | |
| HumidifierOffFeedback | Indicates that the humidifier is off. | |
| HumidityCallFeedbacks | Returns a collection of components that indicate when the system is calling for humidity. | |
| HumiditySetpoint | Sets the humidity regulating setpoint in whole numbers. Valid values range from 5 to 90. Out of range values are ignored. | |
| HumiditySetpointFeedback | Reports the humidity regulating setpoint. | |
| HumiditySetpointMinus | Lowers the humidity regulating setpoint. Continuing to assert the up or down inputs at the limits of the setpoint will not affect the setpoint. That is, the setpoint will hold at its maximum or minimum setting. | |
| HumiditySetpointPlus | Raises the humidity regulating setpoint. Continuing to assert the up or down inputs at the limits of the setpoint will not affect the setpoint. That is, the setpoint will hold at its maximum or minimum setting. | |
| ID |
Property to get the ID of the device.
(Inherited from GenericDevice) | |
| IndoorHumidityInput | Receives the indoor relative humidity from a sensor that is not connected to the thermostat, for display on the Main page of the thermostat LCD (CHV-TSTAT only). This value is ignored if a humidity sensor (CHV-RTHS) is connected to the CHV-TSTAT. | |
| InterstageDifferential | Reports the interstage differential in tenths of a degree. This is the proportional temperature error to trigger the second (Auxiliary) stage. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. This property is not supported by ChvTstatFcu Thermostat. | |
| IsOnline |
Property to get the current online state of the device.
(Inherited from GenericDevice) | |
| LCDContrast |
Reports the LCD screen contrast.
Values range from 1 (lightest) to 10 (darkest).
(Inherited from CresnetThermostat) | |
| LocalHumidity | Reports the relative humidity reading of the built-in humidity sensor (CHV-THSTAT only) in whole numbers. The internal humidity sensor reading is reported regardless of the Use or Omit designation. | |
| LocalHumInvalid | Indicates that the corresponding when remote humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent. | |
| LocalTemperatureFeedback |
Reports the local temperature reported by the Local sensor.
Only enabled when EnableSensorOutputs is enabled.
This property is supported by "HZThstat" not supported by "DinThstat".
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| LocalTemperatureInvalid |
Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data.
The output remains true for as long as the sensor source doesn't have valid data.
This can indicate a problem with the sensor, or the sensor being absent.
(Inherited from CresnetThermostat) | |
| MainScrnObHumidity | Reports the reading that will be displayed under the current temperature on the Main page of the thermostat LCD. | |
| MainScrnObNA |
Reports that NA will be displayed under the current temperature on the Main page of the thermostat LCD.
(Inherited from CresnetThermostat) | |
| MainScrnObOutdoor |
Reports that outdoor will be displayed under the current temperature on the Main page of the thermostat LCD.
(Inherited from CresnetThermostat) | |
| MainScrnObSlabTemperature |
Reports that slab will be displayed under the current temperature on the Main page of the thermostat LCD.
(Inherited from CresnetThermostat) | |
| MaxSlabTemperature | Reports the maximum slab temperature value. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Values range from 390 to 1220 (39° to 122°F); or 44 to 500 (4° to 50°C). This property is not supported by ChvTstatFcu Thermostat. | |
| MsgField |
Sends text string to the Messages page of the thermostat LCD.
Displayed text is limited to approximately 20 characters per line (including spaces) to a maximum of four lines.
The thermostat supports word wrap and auto-hyphenation within the 20 characters/spaces per line maximum.
(Carriage returns will force a line change.)
(Inherited from CresnetThermostat) | |
| MsgIconOn |
Alternately flashes the text "View Msg" with "Online/Hold, Net Fault" on the Main page of the thermostat LCD,
for as long as the input remains true. This alerts the user to check for a displayed message on the Messages page of the thermostat LCD.
(Inherited from CresnetThermostat) | |
| MsgWaiting |
Indicates that text has been sent to the Messages page of the thermostat LCD, via the MsgField input.
The output remains true until the user presses the Clear button on the Messages page.
(Inherited from CresnetThermostat) | |
| Name |
Get the name of this device.
(Inherited from GenericBase) | |
| NoAutoMode |
Indicates that auto mode has been disabled. The output remains true for as long as auto mode is off.
Auto mode can be enabled or disabled from the Setup menu.
(Inherited from CresnetThermostat) | |
| ODHumInvalid | Indicates that the corresponding when remote humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent. | |
| ODRem1Humidity | Reports the designator assigned to the remote sensors. | |
| ODRem1Temperature |
Reports the designator assigned to the remote sensors.
(Inherited from CresnetThermostat) | |
| ODRem2Humidity | Reports the designator assigned to the remote sensors. | |
| ODRem2Temperature |
Reports the designator assigned to the remote sensors.
(Inherited from CresnetThermostat) | |
| ODTemperatureInvalid |
Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data.
The output remains true for as long as the sensor source doesn't have valid data.
This can indicate a problem with the sensor, or the sensor being absent.
(Inherited from CresnetThermostat) | |
| OfflineHold |
Indicates that the thermostat has been taken offline. In this mode, the thermostat is "on hold" and data flows one way,
from the thermostat to Cresnet. All Cresnet commands to the thermostat are blocked except for the Hold Off command.
While the thermostat is "on hold" it buffers all setpoint and mode changes (except for up/down inputs).
The setpoints and mode inputs will take effect immediately when the hold is released.
Remains true for as long as the thermostat is offline.
(Inherited from CresnetThermostat) | |
| OmitLocalHumidity | Reports the designator assigned to the local (internal) sensors. | |
| OmitLocalTemperature |
Reports if temperature is assigned to the local (internal) sensors.
The CHV-TSTAT provides one internal temperature sensor; the CHV-THSTAT provides internal sensors for temperature and humidity.
Each sensor must be designated as Use or Omit.
Readings from local and remote sensors that have the same designator are averaged together.
Thus two temperature sensors set to Use are averaged for the air temperature control,
while two humidity sensors set to Use are averaged to determine the humidity.
A sensor designated as "Omit" signifies that the reading will not be included in such averaging.
(Inherited from CresnetThermostat) | |
| OmitRem1Humidity | Reports the designator assigned to the remote sensors. | |
| OmitRem1Temperature |
Reports the designator assigned to the remote sensors.
(Inherited from CresnetThermostat) | |
| OmitRem2Humidity | Reports the designator assigned to the remote sensors. | |
| OmitRem2Temperature |
Reports the designator assigned to the remote sensors.
(Inherited from CresnetThermostat) | |
| OutdoorHumidity | Reports the humidity reading of any humidity sensor set to "OD" (Outdoor) in whole numbers. If more than one humidity sensor is set to OD, this is the mean outdoor humidity. Humidity sensors are manually set to Use, Omit, or Outdoor via the setup menus on the thermostat. | |
| OutdoorHumidityInput | Receives the outdoor relative humidity from a sensor that is not connected to the thermostat, for display on the Outdoor page of the thermostat LCD. | |
| OutdoorTemperatureFeedback |
Sends the current outdoor temperature to the thermostat.
This input should only be used for heatpump/dual fuel balance point systems, not heat/cool system types.
The value should be sent in tenths of a degree (1d = 0.1 degrees) based on the current temperature scale (Fahrenheit or Celsius).
For example, if the outdoor temperature is 45.3°F, the value should be 453.
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| OutdoorTemperatureInput |
Sends the current outdoor temperature to the thermostat.
This input should only be used for heatpump/dual fuel balance point systems, not heat/cool system types.
The value should be sent in tenths of a degree (1d = 0.1 degrees) based on the current temperature scale (Fahrenheit or Celsius).
For example, if the outdoor temperature is 45.3°F, the value should be 453d.
(Inherited from Thermostat) | |
| Parent |
The parent that a given object was added to.
(Inherited from GenericBase) | |
| Point5CSteps |
Indicates that the temperature in Celsius will be displayed in half degrees.
(Inherited from CresnetThermostat) | |
| RadiantSubtype | Indicates the current subtype for heating/cooling systems. This property is not supported by ChvTstatFcu Thermostat. | |
| RegHumInvalid | Indicates that the corresponding when remote humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent. | |
| Registerable |
Property to indicate that this device can be registered.
(Inherited from GenericDevice) | |
| Registered |
Property to get the current registration state of the device.
(Inherited from GenericDevice) | |
| RegistrationFailureReason |
Property to get the Registration Failure Reason, this will match the return value from the call to register.
(Inherited from GenericDevice) | |
| RegTemperatureInvalid |
Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data.
The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor,
or the sensor being absent.
(Inherited from CresnetThermostat) | |
| RegulationHumidity | Reports the mean (averaged) humidity reading of all internal and remote humidity sensors set to "Use", in whole numbers. Humidity sensors are manually set to Use, Omit, or Outdoor via the setup menus on the thermostat. | |
| RegulationTemperatureFeedback |
Reports displayed temperature, which can be the Local temperature or the Remote 1 temperature, or the average of Local and Remote 1,
based on the option selected in the Setup menu (Local = i; Remote 1 = r; Average = ir).
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| Rem1HumInvalid | Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent. | |
| Rem1TemperatureInvalid |
Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data.
The output remains true for as long as the sensor source doesn't have valid data.
This can indicate a problem with the sensor, or the sensor being absent.
(Inherited from CresnetThermostat) | |
| Rem2HumInvalid | Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent. | |
| Rem2TemperatureInvalid |
Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data.
The output remains true for as long as the sensor source doesn't have valid data.
This can indicate a problem with the sensor, or the sensor being absent.
(Inherited from CresnetThermostat) | |
| Remote1Humidity | Reports the humidity reading of the Remote 1 humidity sensor in whole numbers. The Remote 1 humidity reading is reported regardless of the Use/Omit/OD designation. | |
| Remote1TemperatureFeedback |
Reports the temperature reported by the Remote 1 sensor.
Only enabled when EnableSensorOutputs is enabled.
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| Remote2Humidity | Reports the humidity reading of the Remote 2 humidity sensor in whole numbers. The Remote 2 humidity reading is reported regardless of the Use/Omit/OD designation. | |
| Remote2TemperatureFeedback |
Reports the local temperature reported by the Remote 2 sensor.
Only enabled when EnableSensorOutputs is enabled.
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| RemotePageOneDownButton |
Indicates the state of the Down button on Remote Page one of the thermostat LCD.
The output remains true for as long as the button is pressed.
The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons.
In this mode the buttons can trigger non-HVAC "remote" functions such as AV control, lighting, or alarm activation.
(Inherited from CresnetThermostat) | |
| RemotePageOneDownButtonLabel |
Sends text label for display next to the Down button on Remote Page one of the thermostat LCD.
The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons.
In this mode the buttons can trigger non-HVAC functions such as AV control, lighting, or alarm activation.
(Inherited from CresnetThermostat) | |
| RemotePageOneUpButton |
Indicates the state of the Up button on Remote Page one of the thermostat LCD.
The output remains true for as long as the button is pressed.
The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons.
In this mode the buttons can trigger non-HVAC "remote" functions such as AV control, lighting, or alarm activation.
(Inherited from CresnetThermostat) | |
| RemotePageOneUpButtonLabel |
Sends text label for display next to the Up button on Remote Page one of the thermostat LCD.
The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons.
In this mode the buttons can trigger non-HVAC functions such as AV control, lighting, or alarm activation.
(Inherited from CresnetThermostat) | |
| RemotePageTwoDownButton |
Indicates the state of the Down button on Remote Page two of the thermostat LCD.
The output remains true for as long as the button is pressed.
The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons.
In this mode the buttons can trigger non-HVAC "remote" functions such as AV control, lighting, or alarm activation.
(Inherited from CresnetThermostat) | |
| RemotePageTwoDownButtonLabel |
Sends text label for display next to the Down button on Remote Page two of the thermostat LCD.
The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons.
In this mode the buttons can trigger non-HVAC functions such as AV control, lighting, or alarm activation.
(Inherited from CresnetThermostat) | |
| RemotePageTwoUpButton |
Indicates the state of the Up button on Remote Page two of the thermostat LCD.
The output remains true for as long as the button is pressed.
The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons.
In this mode the buttons can trigger non-HVAC "remote" functions such as AV control, lighting, or alarm activation.
(Inherited from CresnetThermostat) | |
| RemotePageTwoUpButtonLabel |
Sends text label for display next to the Up button on Remote Page two of the thermostat LCD.
The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons.
In this mode the buttons can trigger non-HVAC functions such as AV control, lighting, or alarm activation.
(Inherited from CresnetThermostat) | |
| RevSmodeDir |
Indicates the direction of system mode toggling in response to up/down button presses.
The output becomes true when the Setup option for "Reverse System Mode Direction" is set to "Y".
In this mode, the UP button moves the mode select box to the right instead of to the left.
(Inherited from CresnetThermostat) | |
| RunBacklight |
Turns on the thermostat's backlight for 8 seconds.
(Inherited from CresnetThermostat) | |
| RunFanHeatCalls |
Indicates that Run Fan in Heat Calls has been enabled. The output remains true for as long as the mode is enabled.
Run Fan in Heat Calls is a device setting that activates the fan output with W1/W2 heat calls.
Does not enable operation on slab systems on the slab (W1) call.
(Inherited from CresnetThermostat) | |
| SIMPLDeviceImplementation |
Internal protected member used for actual device control.
(Inherited from GenericDevice) | |
| Slab1Type | Indicates the current slab system type. This property is not supported by ChvTstatFcu Thermostat. | |
| Slab2Type | Indicates the current slab system type. This property is not supported by ChvTstatFcu Thermostat. | |
| Slab3Type | Indicates the current slab system type. This property is not supported by ChvTstatFcu Thermostat. | |
| Slab4AType | Indicates the current slab system type. This property is not supported by ChvTstatFcu Thermostat. | |
| Slab4BType | Indicates the current slab system type. This property is not supported by ChvTstatFcu Thermostat. | |
| Slab5AType | Indicates the current slab system type. This property is not supported by ChvTstatFcu Thermostat. | |
| Slab5BType | Indicates the current slab system type. This property is not supported by ChvTstatFcu Thermostat. | |
| SlabHeatCallFeedbacks | Returns a collection of components that indicate when the system is calling for slab heat. This property is not supported by ChvTstatFcu Thermostat. | |
| SlabMinSetpointMinus | Lowers the slab regulating setpoint. This property is not supported by ChvTstatFcu Thermostat. | |
| SlabMinSetpointPlus | Raises the slab regulating setpoint. This property is not supported by ChvTstatFcu Thermostat. | |
| SlabRegulation | Reports the slab temperature regulation value. Values range from 1 to 6. A lower number signifies less frequent cycles and slower response (looser regulation), while a higher number signifies more frequent cycles and faster response (tighter regulation). This property is not supported by ChvTstatFcu Thermostat. | |
| SlabRem1Temperature |
Reports the designator assigned to the remote sensors.
(Inherited from CresnetThermostat) | |
| SlabRem2Temperature |
Reports the designator assigned to the remote sensors.
(Inherited from CresnetThermostat) | |
| SlabSetpoint | Sets the slab regulating setpoint in tenths of a degree. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. The displayed setpoint value is rounded to whole degrees Fahrenheit or Celsius, or half-degrees Celsius if that option is enabled. This property is not supported by ChvTstatFcu Thermostat. | |
| SlabSetpointFeedback | Reports the slab regulating setpoint in tenths of a degree. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. This property is not supported by ChvTstatFcu Thermostat. | |
| SlabTemperature |
Reports the temperature reading of any remote sensor set to "Slab", in tenths of a degree.
The scale (Fahrenheit or Celsius) is based on the current setting in the unit.
If more than one sensor is set to "Slab", this is the mean slab temperature.
Sensors are set to Use, Omit, OD (Outdoor) or Slab via the setup menus on the thermostat.
(Inherited from CresnetThermostat) | |
| SlabTemperatureInvalid |
Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data.
The output remains true for as long as the sensor source doesn't have valid data.
This can indicate a problem with the sensor, or the sensor being absent.
(Inherited from CresnetThermostat) | |
| SysModeAuto |
Selects auto mode (auto selects heat or cool).
(Inherited from CresnetThermostat) | |
| SysModeAutoFeedback |
Reports if auto mode is the current system mode.
(Inherited from CresnetThermostat) | |
| SysModeAuxHeatOnly | Selects auxiliary heat-only mode for heat pump systems (no effect on a heat/cool system). This property is not supported by ChvTstatFcu Thermostat. | |
| SysModeAuxHeatOnlyFeedback | Reports the current system mode. This property is not supported by ChvTstatFcu Thermostat. | |
| SysModeCool |
Selects cool-only mode.
(Inherited from CresnetThermostat) | |
| SysModeCoolFeedback |
Reports if cool mode is the current system mode.
(Inherited from CresnetThermostat) | |
| SysModeHeat |
Selects heat-only mode.
(Inherited from CresnetThermostat) | |
| SysModeHeatFeedback |
Reports if heat mode is the current system mode.
(Inherited from CresnetThermostat) | |
| SysModeOff |
Selects off mode (no HVAC operation).
(Inherited from CresnetThermostat) | |
| SysModeOffFeedback |
Reports if off mode is the current system mode.
(Inherited from CresnetThermostat) | |
| TemperatureDegC |
Indicates that Celcius is the temperature scale.
(Inherited from CresnetThermostat) | |
| TemperatureDegF |
Indicates that Fahrenheit is the temperature scale.
(Inherited from CresnetThermostat) | |
| TemperatureDispOffset |
Reports the temperature offset in tenths of a degree.
The offset is the number of degrees added or subtracted from the actual sensed temperature. The scale (Fahrenheit or Celsius)
is based on the current setting in the unit.
Values are as follows:
Fahrenheit: -60 to +60 (-6˚ to +6˚F)
Celsius: -30 to +30 (-3˚ to +3˚C)
Half degrees Celsius mode: -35 to +35 (-3.5˚to +3.5˚C)
This temperature offset changes the actual regulated temperature, not just the displayed temperature.
The offset is set to "0" as shipped from the factory.
(Inherited from CresnetThermostat) | |
| Type |
Property to determine to type of device this is.
(Inherited from GenericDevice) | |
| UnRegistrationFailureReason |
Property to get the Unregistration Failure Reason, this will match the return value from the call to unregister.
(Inherited from GenericDevice) | |
| UseLocalHumidity | Reports the designator assigned to the local (internal) sensors. | |
| UseLocalTemperature |
Reports if temperature is assigned to the local (internal) sensors.
The CHV-TSTAT provides one internal temperature sensor; the CHV-THSTAT provides internal sensors for temperature and humidity.
Each sensor must be designated as Use or Omit.
Readings from local and remote sensors that have the same designator are averaged together.
Thus two temperature sensors set to Use are averaged for the air temperature control,
while two humidity sensors set to Use are averaged to determine the humidity.
A sensor designated as "Omit" signifies that the reading will not be included in such averaging.
(Inherited from CresnetThermostat) | |
| UseRem1Humidity | Reports the designator assigned to the remote sensors. | |
| UseRem1Temperature |
Reports the designator assigned to the remote sensors.
(Inherited from CresnetThermostat) | |
| UseRem2Humidity | Reports the designator assigned to the remote sensors. | |
| UseRem2Temperature |
Reports the designator assigned to the remote sensors.
(Inherited from CresnetThermostat) | |
| UserSpecifiedObject |
Can be assigned anything that user wants.
(Inherited from GenericBase) | |
| WideRangeCool |
Indicates that wide range cool mode has been enabled. The output remains true for as long as the mode is enabled.
Wide range cool extends the cool setpoint range to the full auto range of 38° to 99°F, or 3° to 37°C.
This is suitable for wine cellars or other colder chilling processes.
(Inherited from CresnetThermostat) | |
| XioEndpointStubSIMPLDevice |
The SIMPL "stub" Device that the XiO Director creates for an endpoint to send the 1C/0E to the
correct place in hierarchy.
(Inherited from GenericDevice) |
| Name | Description | |
|---|---|---|
| BaseEvent |
Generic base event, triggered when the there are no other handlers available
for a specific EventID.
(Inherited from GenericBase) | |
| ClimateControlComponentCallChange |
Event fired when a climate component change was received from the device.
(Inherited from Thermostat) | |
| FanCallChange |
Event fired when a fan change was received from the device.
(Inherited from Thermostat) | |
| HumidityEvent | Event fired when a humidity state change was received from the device. | |
| IpInformationChange |
Event that tells what IP Address is connected/disconnected from an IP ID for a non-UDP device.
This is only valid for an Ethernet device. An exception will be thrown if it is not.
(Inherited from GenericDevice) | |
| OnlineStatusChange |
Event triggered when the Online status of the device changes.
(Inherited from GenericDevice) | |
| TemperatureChange |
Event fired when a temperature change was received from the device.
(Inherited from Thermostat) |
| Name | Description | |
|---|---|---|
| _AUXBalancePoint | Reports the aux balance point in tenths of a degree. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Values range from 0 to 900 (0?to 90?F); or -180 to +320 (-18?to 32?C). The auxiliary balance point is the outdoor temperature above which auxiliary heat is locked out. | |
| _CoolCallFeedbacks |
Returns a collection of components that indicate when the system is calling for cooling.
(Inherited from Thermostat) | |
| _CoolStages1 | Indicates how many stages of cooling there are in the system. | |
| _CoolStages2 | Indicates how many stages of cooling there are in the system. | |
| _CurrentSystemStateSlot |
Current system state slot device.
(Inherited from Thermostat) | |
| _DualFuelSubtype | Indicates the current subtype for heating/cooling systems. In dual-fuel setups, the auxiliary heat output runs in place of the heat pump in cold weather. | |
| _FanCall | Indicates that the fan is running (for any reason). Remains true for as long as the fan is running. | |
| _FloorWarmSysModeHeat | Turns the floor-warming system on. | |
| _FloorWarmSysModeHeatFB | Reports the status of the floor-warming system. | |
| _FloorWarmSysModeOff | Turns the floor-warming system off. | |
| _FloorWarmSysModeOffFB | Reports the status of the floor-warming system. | |
| _ForceAirSubtype | Indicates the current subtype for heating/cooling systems. Forced air is a type of heating system that uses a blower motor to move air through the furnace and into the ductwork. | |
| _HeatCallFeedbacks |
A collection of components that indicate when the system is calling for heat.
(Inherited from Thermostat) | |
| _HeatCoolControlSlot |
Heat/cool control slot device.
(Inherited from Thermostat) | |
| _HeatCoolType | Indicates the current heat system type. | |
| _HeatPumpType | Indicates the current heat system type. | |
| _HeatStages1 | Indicates how many stages of heating there are in the system. | |
| _HeatStages2 | Indicates how many stages of heating there are in the system. | |
| _HPBalancePoint | Reports the heat pump balance point in tenths of a degree. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Values range from 0 to 900 (0?to 90?F); or -180 to +320 (-18?to 32?C). The heat pump balance point is the outdoor temperature below which heat pump operation is locked out, and auxiliary heat runs in place of it. | |
| _HumidityCallFeedbacks | A collection of components that indicate when the system is calling for humidity. | |
| _InterstageDifferential | Reports the interstage differential in tenths of a degree. This is the proportional temperature error to trigger the second (Auxiliary) stage. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Values range from 0.5 to 3.0 (5° to 30°F); or 0.25 to 2.0 (3° to 20°C). | |
| _MaxSlabTemp | Reports the maximum slab temperature value. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Values range from 390 to 1220 (39° to 122°F); or 44 to 500 (4° to 50°C). | |
| _RadiantSubtype | Indicates the current subtype for heating/cooling systems. Radiant heating turns large areas (floor, walls, ceilings) into large surface radiators. | |
| _Slab1Type | Indicates the current slab system type. | |
| _Slab2Type | Indicates the current slab system type. | |
| _Slab3Type | Indicates the current slab system type. | |
| _Slab4AType | Indicates the current slab system type. | |
| _Slab4BType | Indicates the current slab system type. | |
| _Slab5AType | Indicates the current slab system type. | |
| _Slab5BType | Indicates the current slab system type. | |
| _SlabControlSlot | Slab control slot device. | |
| _SlabMinSetpointMinus | Lowers the slab regulating setpoint. | |
| _SlabMinSetpointPlus | Raises the slab regulating setpoint. | |
| _SlabRegulation | Reports the slab temperature regulation value. Values range from 1 to 6. A lower number signifies less frequent cycles and slower response (looser regulation), while a higher number signifies more frequent cycles and faster response (tighter regulation). | |
| _SysModeAuxHeatOnly | Selects the system mode. | |
| _SystemConfigurationSlot |
System configuration slot device.
(Inherited from Thermostat) | |
| AUXBalancePointEventId | Event ID for the base event for reporting the auxiliary balance point in tenths of a degree. | |
| CoolStages1EventId | Event ID for the base event for indicating how many stages of cooling there are in the system. | |
| CoolStages2EventId | Event ID for the base event for indicating how many stages of cooling there are in the system. | |
| DualFuelSubtypeEventId | Event ID for the base event for indicating the current subtype for heating/cooling systems. | |
| FloorWarmSysModeHeatFeedbackEventId | Event ID for the base event for reporting the status of the floor-warming system. | |
| FloorWarmSysModeOffFeedbackEventId | Event ID for the base event for reporting the status of the floor-warming system. | |
| ForcedAirSubtypeEventId | Event ID for the base event for indicating the current subtype for heating/cooling systems. | |
| HeatCoolTypeEventId | Event ID for the base event for indicating the current heat system type. | |
| HeatPumpTypeEventId | Event ID for the base event for indicating the current heat system type. | |
| HeatStages1EventId | Event ID for the base event for indicating how many stages of heating there is in the system. | |
| HeatStages2EventId | Event ID for the base event for indicating how many stages of heating there is in the system. | |
| HPBalancePointEventId | Event ID for the base event for reporting the heat pump balance point in tenths of a degree. | |
| HTherm | Humidity thermostat component of thermostat. | |
| InterstageDifferentialEventId | Event ID for the base event for reporting the interstage differential in tenths of a degree. | |
| MaxSlabTemperatureFeedbackEventId | Event ID for the base event for reporting the maximum slab temperature value. | |
| NumberOfAuxHeatStages | The number of auxiliary heat stages on this device. | |
| NumberOfCoolStages | The number of cool stages on this device. | |
| NumberOfHeatStages | The number of heat stages on this device. | |
| NumberOfHumidifierStages | The number of humidity stages on this device. | |
| NumberOfSlabHeatStages | The number of slab heat stages on this device. | |
| RadiantSubtypeEventId | Event ID for the base event for indicating the subtype for heating/cooling systems. | |
| Slab1TypeEventId | Event ID for the base event for indicating the current slab system type. | |
| Slab2TypeEventId | Event ID for the base event for indicating the current slab system type. | |
| Slab3TypeEventId | Event ID for the base event for indicating the current slab system type. | |
| Slab4ATypeEventId | Event ID for the base event for indicating the current slab system type. | |
| Slab4BTypeEventId | Event ID for the base event for indicating the current slab system type. | |
| Slab5ATypeEventId | Event ID for the base event for indicating the current slab system type. | |
| Slab5BTypeEventId | Event ID for the base event for indicating the current slab system type. | |
| SlabRegulationEventId | Event ID for the base event for reporting the slab temperature regulation value. | |
| SlabSetpointFeedbackEventId | Sets the slab regulating setpoint in tenths of a degree. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Valid values range from 380 to 1210 (38° to 121°F); or 3 to 495 (3° to 49.5°C). | |
| SysModeAuxHeatOnlyFeedbackEventId | Event ID for the base event for reporting the current system mode. |