The SingleSpeedFan type exposes the following members.
| Name | Description | |
|---|---|---|
| _AUXBalancePoint | Reports the aux balance point in tenths of a degree. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Values range from 0 to 900 (0?to 90?F); or -180 to +320 (-18?to 32?C). The auxiliary balance point is the outdoor temperature above which auxiliary heat is locked out. | |
| _CoolCallFeedbacks |
Returns a collection of components that indicate when the system is calling for cooling.
(Inherited from Thermostat) | |
| _CoolStages1 | Indicates how many stages of cooling there are in the system. | |
| _CoolStages2 | Indicates how many stages of cooling there are in the system. | |
| _CurrentSystemStateSlot |
Current system state slot device.
(Inherited from Thermostat) | |
| _DualFuelSubtype | Indicates the current subtype for heating/cooling systems. In dual-fuel setups, the auxiliary heat output runs in place of the heat pump in cold weather. | |
| _FanCall | Indicates that the fan is running (for any reason). Remains true for as long as the fan is running. | |
| _FloorWarmSysModeHeat | Turns the floor-warming system on. | |
| _FloorWarmSysModeHeatFB | Reports the status of the floor-warming system. | |
| _FloorWarmSysModeOff | Turns the floor-warming system off. | |
| _FloorWarmSysModeOffFB | Reports the status of the floor-warming system. | |
| _ForceAirSubtype | Indicates the current subtype for heating/cooling systems. Forced air is a type of heating system that uses a blower motor to move air through the furnace and into the ductwork. | |
| _HeatCallFeedbacks |
A collection of components that indicate when the system is calling for heat.
(Inherited from Thermostat) | |
| _HeatCoolControlSlot |
Heat/cool control slot device.
(Inherited from Thermostat) | |
| _HeatCoolType | Indicates the current heat system type. | |
| _HeatPumpType | Indicates the current heat system type. | |
| _HeatStages1 | Indicates how many stages of heating there are in the system. | |
| _HeatStages2 | Indicates how many stages of heating there are in the system. | |
| _HPBalancePoint | Reports the heat pump balance point in tenths of a degree. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Values range from 0 to 900 (0?to 90?F); or -180 to +320 (-18?to 32?C). The heat pump balance point is the outdoor temperature below which heat pump operation is locked out, and auxiliary heat runs in place of it. | |
| _HumidityCallFeedbacks | A collection of components that indicate when the system is calling for humidity. | |
| _InterstageDifferential | Reports the interstage differential in tenths of a degree. This is the proportional temperature error to trigger the second (Auxiliary) stage. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Values range from 0.5 to 3.0 (5° to 30°F); or 0.25 to 2.0 (3° to 20°C). | |
| _MaxSlabTemp | Reports the maximum slab temperature value. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Values range from 390 to 1220 (39° to 122°F); or 44 to 500 (4° to 50°C). | |
| _RadiantSubtype | Indicates the current subtype for heating/cooling systems. Radiant heating turns large areas (floor, walls, ceilings) into large surface radiators. | |
| _Slab1Type | Indicates the current slab system type. | |
| _Slab2Type | Indicates the current slab system type. | |
| _Slab3Type | Indicates the current slab system type. | |
| _Slab4AType | Indicates the current slab system type. | |
| _Slab4BType | Indicates the current slab system type. | |
| _Slab5AType | Indicates the current slab system type. | |
| _Slab5BType | Indicates the current slab system type. | |
| _SlabControlSlot | Slab control slot device. | |
| _SlabMinSetpointMinus | Lowers the slab regulating setpoint. | |
| _SlabMinSetpointPlus | Raises the slab regulating setpoint. | |
| _SlabRegulation | Reports the slab temperature regulation value. Values range from 1 to 6. A lower number signifies less frequent cycles and slower response (looser regulation), while a higher number signifies more frequent cycles and faster response (tighter regulation). | |
| _SysModeAuxHeatOnly | Selects the system mode. | |
| _SystemConfigurationSlot |
System configuration slot device.
(Inherited from Thermostat) | |
| AUXBalancePointEventId | Event ID for the base event for reporting the auxiliary balance point in tenths of a degree. | |
| CoolStages1EventId | Event ID for the base event for indicating how many stages of cooling there are in the system. | |
| CoolStages2EventId | Event ID for the base event for indicating how many stages of cooling there are in the system. | |
| DualFuelSubtypeEventId | Event ID for the base event for indicating the current subtype for heating/cooling systems. | |
| FloorWarmSysModeHeatFeedbackEventId | Event ID for the base event for reporting the status of the floor-warming system. | |
| FloorWarmSysModeOffFeedbackEventId | Event ID for the base event for reporting the status of the floor-warming system. | |
| ForcedAirSubtypeEventId | Event ID for the base event for indicating the current subtype for heating/cooling systems. | |
| HeatCoolTypeEventId | Event ID for the base event for indicating the current heat system type. | |
| HeatPumpTypeEventId | Event ID for the base event for indicating the current heat system type. | |
| HeatStages1EventId | Event ID for the base event for indicating how many stages of heating there is in the system. | |
| HeatStages2EventId | Event ID for the base event for indicating how many stages of heating there is in the system. | |
| HPBalancePointEventId | Event ID for the base event for reporting the heat pump balance point in tenths of a degree. | |
| HTherm | Humidity thermostat component of thermostat. | |
| InterstageDifferentialEventId | Event ID for the base event for reporting the interstage differential in tenths of a degree. | |
| MaxSlabTemperatureFeedbackEventId | Event ID for the base event for reporting the maximum slab temperature value. | |
| NumberOfAuxHeatStages | The number of auxiliary heat stages on this device. | |
| NumberOfCoolStages | The number of cool stages on this device. | |
| NumberOfHeatStages | The number of heat stages on this device. | |
| NumberOfHumidifierStages | The number of humidity stages on this device. | |
| NumberOfSlabHeatStages | The number of slab heat stages on this device. | |
| RadiantSubtypeEventId | Event ID for the base event for indicating the subtype for heating/cooling systems. | |
| Slab1TypeEventId | Event ID for the base event for indicating the current slab system type. | |
| Slab2TypeEventId | Event ID for the base event for indicating the current slab system type. | |
| Slab3TypeEventId | Event ID for the base event for indicating the current slab system type. | |
| Slab4ATypeEventId | Event ID for the base event for indicating the current slab system type. | |
| Slab4BTypeEventId | Event ID for the base event for indicating the current slab system type. | |
| Slab5ATypeEventId | Event ID for the base event for indicating the current slab system type. | |
| Slab5BTypeEventId | Event ID for the base event for indicating the current slab system type. | |
| SlabRegulationEventId | Event ID for the base event for reporting the slab temperature regulation value. | |
| SlabSetpointFeedbackEventId | Sets the slab regulating setpoint in tenths of a degree. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Valid values range from 380 to 1210 (38° to 121°F); or 3 to 495 (3° to 49.5°C). | |
| SysModeAuxHeatOnlyFeedbackEventId | Event ID for the base event for reporting the current system mode. |