CresnetThermostatOmitLocalTemperature Property

Reports if temperature is assigned to the local (internal) sensors. The CHV-TSTAT provides one internal temperature sensor; the CHV-THSTAT provides internal sensors for temperature and humidity. Each sensor must be designated as Use or Omit. Readings from local and remote sensors that have the same designator are averaged together. Thus two temperature sensors set to Use are averaged for the air temperature control, while two humidity sensors set to Use are averaged to determine the humidity. A sensor designated as "Omit" signifies that the reading will not be included in such averaging.

Namespace: Crestron.SimplSharpPro.Thermostats
Assembly: Crestron.SimplSharpPro.Thermostats (in Crestron.SimplSharpPro.Thermostats.dll) Version: 2.21.121
Syntax
C#
public BoolOutputSig OmitLocalTemperature { get; }

Property Value

BoolOutputSig