Cresnet |
public class CresnetThermostat : Thermostat
The CresnetThermostat type exposes the following members.
| Name | Description | |
|---|---|---|
| CresnetThermostat | Base constructor for Cresnet thermostat devices. |
| Name | Description | |
|---|---|---|
| Auto1ptSetpoint |
Sets the auto1pt setpoint, where 1d = 0.1 degrees.
The value is based on the current temperature scale (Fahrenheit or Celsius).
The displayed value is rounded to whole or half degrees based on the setting.
(Inherited from Thermostat) | |
| Auto1ptSetpointFeedback |
Reports the active auto1pt setpoint value.
This output should be connected to the corresponding setpoint input; otherwise the output will not report the setpoint value.
The BaseEvent event will trigger with Auto1ptSetpointFeedbackEventId. (Inherited from Thermostat) | |
| Auto1ptSetpointMinus | Lowers the temperature regulating setpoint for single-point auto only. | |
| Auto1ptSetpointPlus | Raises the temperature regulating setpoint for single-point auto only. | |
| AutoDeadbandFeedback |
Reports the auto deadband value selected via the "db" option in the Setup menu, where 1d = 0.1 degrees.
In dual-setpoint auto mode, this value is the minimum separation between heat and cool setpoints,
which prevents the system from toggling back and forth due to overshoot.
In single-setpoint auto mode, this value sets the hysteresis used when changing from heat to cool.
For example, if the setpoint is 70°F with auto deadband of 2 degrees,
the temperature would have to rise to 72°F before running cool, and 68°F before running heat.
HZ-THSTAT reports auto mode deadband parameter in 10ths of current unit:
Fahrenheit : 20, 30, 40, 50, 60 (F).
Celsius : 10, 20, 30 (C).
The BaseEvent event will trigger with AutoDeadbandFeedbackEventId. (Inherited from Thermostat) | |
| ColdWeatherComp | Indicates that cold weather compensation has been enabled. The output remains true for as long as the mode is enabled. Outdoor low-temperature compensation modifies the humidifier output to prevent condensation on windows in cold weather. | |
| ConnectedIpList |
A property containing the list of the ConnectedIpInformation objects which contain information about the devices that are connected to this IP ID.
This property is only valid for an ethernet device. If this is not an ethernet device, then this property will return null.
If this is an ethernet device, the list will be non-null. It will be empty if no devices are connected.
The order of items in this list is not guaranteed.
(Inherited from GenericDevice) | |
| CoolAnticipator | Reports the cool anticipator values, from 1 to 6. Prevents overshooting the set temperature. A lower number signifies more frequent cycles and faster response (tighter regulation), while a higher number signifies less frequent cycles and slower response (looser regulation). | |
| CoolCallFeedbacks |
Returns a collection of components that indicate when the system is calling for cooling.
The ClimateControlComponentCallChange event will trigger with ClimateControlComponent object. (Inherited from Thermostat) | |
| CoolSetpoint |
Sets the cool setpoint, where 1d = 0.1 degrees.
The value is based on the current temperature scale (Fahrenheit or Celsius).
The displayed value is rounded to whole or half degrees based on the setting.
(Inherited from Thermostat) | |
| CoolSetpointFeedback |
Reports the active cool setpoint value.
This output should be connected to the corresponding setpoint input; otherwise the output will not report the setpoint value.
The BaseEvent event will trigger with CoolSetpointFeedbackEventId. (Inherited from Thermostat) | |
| CoolSetpointMinus | Lowers the temperature regulating setpoint for cool-only. | |
| CoolSetpointPlus | Raises the temperature regulating setpoint for cool-only. | |
| Description |
Get/Set the description of this device.
(Inherited from GenericBase) | |
| DispGlobalPage | Indicates that the Global page (consisting of the Global Send button) has been enabled for display on the thermostat LCD. The output remains true for as long as the page is enabled. | |
| Disposed |
Property to indicate if the device has been disposed.
(Inherited from GenericDevice) | |
| DispOutdoorPage | Indicates that the Global page (consisting of the Global Send button) has been enabled for display on the thermostat LCD. The output remains true for as long as the page is enabled. | |
| DispRemoteBtnPage1 | Indicates that Remote page 1 has been enabled for display. The output remains true for as long as the page is enabled. The thermostats provide two Remote pages that can be used to trigger non-HVAC functions such as AV control, lighting, or alarm activation. | |
| DispRemoteBtnPage2 | Indicates that Remote page 2 has been enabled for display. The output remains true for as long as the page is enabled. The thermostats provide two Remote pages that can be used to trigger non-HVAC functions such as AV control, lighting, or alarm activation. | |
| DualSetpointsAutoMode | Indicates that dual-point auto mode has been enabled. The output remains true for as long as the mode is enabled. Auto mode can be enabled or disabled from the Setup menu. | |
| FanAuto | Sets the fan to auto mode. In Auto mode, the fan runs only when the system calls. | |
| FanAutoFeedback | Reports if the fan is currently in auto mode. | |
| FanOn | Sets the fan to on mode. In On mode, the fan runs continually. | |
| FanOnFeedback | Reports if the fan is currently in on mode. | |
| FrontPanelLockout | Locks out the four hard pushbuttons on the thermostat for as long as the input remains true. In this mode, pressing the buttons will have no effect. Automatically disabled in case of system error or failure. | |
| GlobalPress | Briefly pulses whenever the Send button of the Global Update page is pressed. This signal can be tied to logic in the program to trigger functions such as global updates of temperature or humidity values. | |
| HeatAnticipator | Reports the heat anticipator values, from 1 to 6. Prevents overshooting the set temperature. A lower number signifies more frequent cycles and faster response (tighter regulation), while a higher number signifies less frequent cycles and slower response (looser regulation). | |
| HeatCallFeedbacks |
Returns a collection of components that indicate when the system is calling for heat.
The ClimateControlComponentCallChange event will trigger with ClimateControlComponent object. (Inherited from Thermostat) | |
| HeatSetpoint |
Sets the heat setpoint, where 1d = 0.1 degrees.
The value is based on the current temperature scale (Fahrenheit or Celsius).
The displayed value is rounded to whole or half degrees based on the setting.
(Inherited from Thermostat) | |
| HeatSetpointFeedback |
Reports the active heat setpoint value.
This output should be connected to the corresponding setpoint input; otherwise the output will not report the setpoint value.
The BaseEvent event will trigger with HeatSetpointFeedbackEventId. (Inherited from Thermostat) | |
| HeatSetpointMinus | Lowers the temperature regulating setpoint for heat-only. | |
| HeatSetpointPlus | Raises the temperature regulating setpoint for heat-only. | |
| HoldOff | Turns off the Hold function. | |
| HoldOn | Turns on the Hold function. | |
| ID |
Property to get the ID of the device.
(Inherited from GenericDevice) | |
| IsOnline |
Property to get the current online state of the device.
(Inherited from GenericDevice) | |
| LCDContrast | Reports the LCD screen contrast. Values range from 1 (lightest) to 10 (darkest). | |
| LocalTemperatureFeedback |
Reports the local temperature reported by the Local sensor.
Only enabled when EnableSensorOutputs is enabled.
This property is supported by "HZThstat" not supported by "DinThstat".
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| LocalTemperatureInvalid | Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent. | |
| MainScrnObNA | Reports that NA will be displayed under the current temperature on the Main page of the thermostat LCD. | |
| MainScrnObOutdoor | Reports that outdoor will be displayed under the current temperature on the Main page of the thermostat LCD. | |
| MainScrnObSlabTemperature | Reports that slab will be displayed under the current temperature on the Main page of the thermostat LCD. | |
| MsgField | Sends text string to the Messages page of the thermostat LCD. Displayed text is limited to approximately 20 characters per line (including spaces) to a maximum of four lines. The thermostat supports word wrap and auto-hyphenation within the 20 characters/spaces per line maximum. (Carriage returns will force a line change.) | |
| MsgIconOn | Alternately flashes the text "View Msg" with "Online/Hold, Net Fault" on the Main page of the thermostat LCD, for as long as the input remains true. This alerts the user to check for a displayed message on the Messages page of the thermostat LCD. | |
| MsgWaiting | Indicates that text has been sent to the Messages page of the thermostat LCD, via the MsgField input. The output remains true until the user presses the Clear button on the Messages page. | |
| Name |
Get the name of this device.
(Inherited from GenericBase) | |
| NoAutoMode | Indicates that auto mode has been disabled. The output remains true for as long as auto mode is off. Auto mode can be enabled or disabled from the Setup menu. | |
| ODRem1Temperature | Reports the designator assigned to the remote sensors. | |
| ODRem2Temperature | Reports the designator assigned to the remote sensors. | |
| ODTemperatureInvalid | Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent. | |
| OfflineHold | Indicates that the thermostat has been taken offline. In this mode, the thermostat is "on hold" and data flows one way, from the thermostat to Cresnet. All Cresnet commands to the thermostat are blocked except for the Hold Off command. While the thermostat is "on hold" it buffers all setpoint and mode changes (except for up/down inputs). The setpoints and mode inputs will take effect immediately when the hold is released. Remains true for as long as the thermostat is offline. | |
| OmitLocalTemperature | Reports if temperature is assigned to the local (internal) sensors. The CHV-TSTAT provides one internal temperature sensor; the CHV-THSTAT provides internal sensors for temperature and humidity. Each sensor must be designated as Use or Omit. Readings from local and remote sensors that have the same designator are averaged together. Thus two temperature sensors set to Use are averaged for the air temperature control, while two humidity sensors set to Use are averaged to determine the humidity. A sensor designated as "Omit" signifies that the reading will not be included in such averaging. | |
| OmitRem1Temperature | Reports the designator assigned to the remote sensors. | |
| OmitRem2Temperature | Reports the designator assigned to the remote sensors. | |
| OutdoorTemperatureFeedback |
Sends the current outdoor temperature to the thermostat.
This input should only be used for heatpump/dual fuel balance point systems, not heat/cool system types.
The value should be sent in tenths of a degree (1d = 0.1 degrees) based on the current temperature scale (Fahrenheit or Celsius).
For example, if the outdoor temperature is 45.3°F, the value should be 453.
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| OutdoorTemperatureInput |
Sends the current outdoor temperature to the thermostat.
This input should only be used for heatpump/dual fuel balance point systems, not heat/cool system types.
The value should be sent in tenths of a degree (1d = 0.1 degrees) based on the current temperature scale (Fahrenheit or Celsius).
For example, if the outdoor temperature is 45.3°F, the value should be 453d.
(Inherited from Thermostat) | |
| Parent |
The parent that a given object was added to.
(Inherited from GenericBase) | |
| Point5CSteps | Indicates that the temperature in Celsius will be displayed in half degrees. | |
| Registerable |
Property to indicate that this device can be registered.
(Inherited from GenericDevice) | |
| Registered |
Property to get the current registration state of the device.
(Inherited from GenericDevice) | |
| RegistrationFailureReason |
Property to get the Registration Failure Reason, this will match the return value from the call to register.
(Inherited from GenericDevice) | |
| RegTemperatureInvalid | Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent. | |
| RegulationTemperatureFeedback |
Reports displayed temperature, which can be the Local temperature or the Remote 1 temperature, or the average of Local and Remote 1,
based on the option selected in the Setup menu (Local = i; Remote 1 = r; Average = ir).
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| Rem1TemperatureInvalid | Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent. | |
| Rem2TemperatureInvalid | Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent. | |
| Remote1TemperatureFeedback |
Reports the temperature reported by the Remote 1 sensor.
Only enabled when EnableSensorOutputs is enabled.
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| Remote2TemperatureFeedback |
Reports the local temperature reported by the Remote 2 sensor.
Only enabled when EnableSensorOutputs is enabled.
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| RemotePageOneDownButton | Indicates the state of the Down button on Remote Page one of the thermostat LCD. The output remains true for as long as the button is pressed. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC "remote" functions such as AV control, lighting, or alarm activation. | |
| RemotePageOneDownButtonLabel | Sends text label for display next to the Down button on Remote Page one of the thermostat LCD. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC functions such as AV control, lighting, or alarm activation. | |
| RemotePageOneUpButton | Indicates the state of the Up button on Remote Page one of the thermostat LCD. The output remains true for as long as the button is pressed. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC "remote" functions such as AV control, lighting, or alarm activation. | |
| RemotePageOneUpButtonLabel | Sends text label for display next to the Up button on Remote Page one of the thermostat LCD. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC functions such as AV control, lighting, or alarm activation. | |
| RemotePageTwoDownButton | Indicates the state of the Down button on Remote Page two of the thermostat LCD. The output remains true for as long as the button is pressed. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC "remote" functions such as AV control, lighting, or alarm activation. | |
| RemotePageTwoDownButtonLabel | Sends text label for display next to the Down button on Remote Page two of the thermostat LCD. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC functions such as AV control, lighting, or alarm activation. | |
| RemotePageTwoUpButton | Indicates the state of the Up button on Remote Page two of the thermostat LCD. The output remains true for as long as the button is pressed. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC "remote" functions such as AV control, lighting, or alarm activation. | |
| RemotePageTwoUpButtonLabel | Sends text label for display next to the Up button on Remote Page two of the thermostat LCD. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC functions such as AV control, lighting, or alarm activation. | |
| RevSmodeDir | Indicates the direction of system mode toggling in response to up/down button presses. The output becomes true when the Setup option for "Reverse System Mode Direction" is set to "Y". In this mode, the UP button moves the mode select box to the right instead of to the left. | |
| RunBacklight | Turns on the thermostat's backlight for 8 seconds. | |
| RunFanHeatCalls | Indicates that Run Fan in Heat Calls has been enabled. The output remains true for as long as the mode is enabled. Run Fan in Heat Calls is a device setting that activates the fan output with W1/W2 heat calls. Does not enable operation on slab systems on the slab (W1) call. | |
| SIMPLDeviceImplementation |
Internal protected member used for actual device control.
(Inherited from GenericDevice) | |
| SlabRem1Temperature | Reports the designator assigned to the remote sensors. | |
| SlabRem2Temperature | Reports the designator assigned to the remote sensors. | |
| SlabTemperature | Reports the temperature reading of any remote sensor set to "Slab", in tenths of a degree. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. If more than one sensor is set to "Slab", this is the mean slab temperature. Sensors are set to Use, Omit, OD (Outdoor) or Slab via the setup menus on the thermostat. | |
| SlabTemperatureInvalid | Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent. | |
| SysModeAuto | Selects auto mode (auto selects heat or cool). | |
| SysModeAutoFeedback | Reports if auto mode is the current system mode. | |
| SysModeCool | Selects cool-only mode. | |
| SysModeCoolFeedback | Reports if cool mode is the current system mode. | |
| SysModeHeat | Selects heat-only mode. | |
| SysModeHeatFeedback | Reports if heat mode is the current system mode. | |
| SysModeOff | Selects off mode (no HVAC operation). | |
| SysModeOffFeedback | Reports if off mode is the current system mode. | |
| TemperatureDegC | Indicates that Celcius is the temperature scale. | |
| TemperatureDegF | Indicates that Fahrenheit is the temperature scale. | |
| TemperatureDispOffset | Reports the temperature offset in tenths of a degree. The offset is the number of degrees added or subtracted from the actual sensed temperature. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Values are as follows: Fahrenheit: -60 to +60 (-6˚ to +6˚F) Celsius: -30 to +30 (-3˚ to +3˚C) Half degrees Celsius mode: -35 to +35 (-3.5˚to +3.5˚C) This temperature offset changes the actual regulated temperature, not just the displayed temperature. The offset is set to "0" as shipped from the factory. | |
| Type |
Property to determine to type of device this is.
(Inherited from GenericDevice) | |
| UnRegistrationFailureReason |
Property to get the Unregistration Failure Reason, this will match the return value from the call to unregister.
(Inherited from GenericDevice) | |
| UseLocalTemperature | Reports if temperature is assigned to the local (internal) sensors. The CHV-TSTAT provides one internal temperature sensor; the CHV-THSTAT provides internal sensors for temperature and humidity. Each sensor must be designated as Use or Omit. Readings from local and remote sensors that have the same designator are averaged together. Thus two temperature sensors set to Use are averaged for the air temperature control, while two humidity sensors set to Use are averaged to determine the humidity. A sensor designated as "Omit" signifies that the reading will not be included in such averaging. | |
| UseRem1Temperature | Reports the designator assigned to the remote sensors. | |
| UseRem2Temperature | Reports the designator assigned to the remote sensors. | |
| UserSpecifiedObject |
Can be assigned anything that user wants.
(Inherited from GenericBase) | |
| WideRangeCool | Indicates that wide range cool mode has been enabled. The output remains true for as long as the mode is enabled. Wide range cool extends the cool setpoint range to the full auto range of 38° to 99°F, or 3° to 37°C. This is suitable for wine cellars or other colder chilling processes. | |
| XioEndpointStubSIMPLDevice |
The SIMPL "stub" Device that the XiO Director creates for an endpoint to send the 1C/0E to the
correct place in hierarchy.
(Inherited from GenericDevice) |
| Name | Description | |
|---|---|---|
| _CurrentSystemStateSlot_CueChange |
Method that handles CurrentSystemState slot events.
(Inherited from Thermostat) | |
| _DisplayFunctions_CueChange | Method that handles DisplayFunctions slot events. | |
| _HeatCoolControlSlot_CueChange |
Method that handles HeatCoolControl slot events.
(Inherited from Thermostat) | |
| _SystemConfigurationSlot_CueChange |
Method that handles SystemConfiguration slot events.
(Inherited from Thermostat) | |
| Dispose |
Clean up of resources.
(Inherited from GenericBase) | |
| Dispose(Boolean) |
Method to perform the actual disposing of the device.
(Inherited from GenericDevice) | |
| Equals | Determines whether the specified object is equal to the current object. (Inherited from Object) | |
| Finalize |
Destructor of the device.
(Inherited from GenericDevice) | |
| GetHashCode | Serves as the default hash function. (Inherited from Object) | |
| GetType | Gets the Type of the current instance. (Inherited from Object) | |
| InitializeDevice | Method used to initialize cresnet thermostats. | |
| MemberwiseClone | Creates a shallow copy of the current Object. (Inherited from Object) | |
| OnBaseEvent(Int32) |
Protected member used to fire the BaseEvent with the default extended information.
(Inherited from GenericBase) | |
| OnBaseEvent(Int32, UInt16) |
Protected member used to fine the BaseEvent with extended event information.
(Inherited from GenericBase) | |
| OnClimateControlComponentEvent |
Method to fire the climate control component change event.
(Inherited from Thermostat) | |
| OnFanCallEvent |
Method to fire the fan event.
(Inherited from Thermostat) | |
| OnTemperatureChange |
Method to fire the temperature change event.
(Inherited from Thermostat) | |
| Register |
Register this device with the system.
(Inherited from GenericDevice) | |
| ToString |
Return the name of the device.
(Inherited from GenericDevice) | |
| UnRegister |
Unregister this device with the system. This function can not be called from the device's own SigChange event handler.
On successful unregistration, if this device supports the OnlineStatusChange event, it will trigger indicating the device when offline. (Inherited from GenericDevice) |
| Name | Description | |
|---|---|---|
| BaseEvent |
Generic base event, triggered when the there are no other handlers available
for a specific EventID.
(Inherited from GenericBase) | |
| ClimateControlComponentCallChange |
Event fired when a climate component change was received from the device.
(Inherited from Thermostat) | |
| FanCallChange |
Event fired when a fan change was received from the device.
(Inherited from Thermostat) | |
| IpInformationChange |
Event that tells what IP Address is connected/disconnected from an IP ID for a non-UDP device.
This is only valid for an Ethernet device. An exception will be thrown if it is not.
(Inherited from GenericDevice) | |
| OnlineStatusChange |
Event triggered when the Online status of the device changes.
(Inherited from GenericDevice) | |
| TemperatureChange |
Event fired when a temperature change was received from the device.
(Inherited from Thermostat) |
| Name | Description | |
|---|---|---|
| _CoolCallFeedbacks |
Returns a collection of components that indicate when the system is calling for cooling.
(Inherited from Thermostat) | |
| _CurrentSystemStateSlot |
Current system state slot device.
(Inherited from Thermostat) | |
| _HeatCallFeedbacks |
A collection of components that indicate when the system is calling for heat.
(Inherited from Thermostat) | |
| _HeatCoolControlSlot |
Heat/cool control slot device.
(Inherited from Thermostat) | |
| _SystemConfigurationSlot |
System configuration slot device.
(Inherited from Thermostat) | |
| ColdWeatherCompEventId | Event ID for the base event for indicating that cold weather compensation has been enabled. | |
| CoolAnticipatorEventId | Event ID for the base event for reporting the cool anticipator values, from 1 to 6. Prevents overshooting the set temperature.. | |
| DispGlobalPageEventId | Event ID for the base event for . | |
| DispOutdoorPageEventId | Event ID for the base event for indicating that the Outdoor page has been enabled for display on the thermostat LCD. | |
| DispRemoteBtnPage1EventId | Event ID for the base event for indicating that Remote page 1 has been enabled for display. | |
| DispRemoteBtnPage2EventId | Event ID for the base event for indicating that Remote page 2 has been enabled for display. | |
| DualSetpointsAutoModeEventId | Event ID for the base event for indicating that dual-point auto mode has been enabled. | |
| FanAutoEventId | Event ID for the base event for reporting the fan mode. | |
| FanOnFeedbackEventId | Event ID for the base event for reporting the fan mode. | |
| GlobalPressEventId | Event ID for the base event for indicating that the Send button of the Global Update page was pressed. | |
| HeatAnticipatorEventId | Event ID for the base event for reporting the heat anticipator values, from 1 to 6. Prevents overshooting the set temperature.. | |
| LCDContrastEventId | Event ID for the base event for reporting the LCD screen contrast.. | |
| LocalTemperatureInvalidEventId | Event ID for the base event for indicating that the corresponding when remote temperature sensor isn't reporting valid data. | |
| MainScrnObNAEventId | Event ID for the base event for reporting if NA will be the reading that will be displayed under the current temperature on the Main page of the thermostat LCD. | |
| MainScrnObOutdoorEventId | Event ID for the base event for reporting if Outdoor will be the reading that will be displayed under the current temperature on the Main page of the thermostat LCD. | |
| MainScrnObSlabTemperatureEventId | Event ID for the base event for reporting if SlabTemp will be the reading that will be displayed under the current temperature on the Main page of the thermostat LCD. | |
| MsgWaitingEventId | Event ID for the base event for indicating that text has been sent to the Messages page of the thermostat LCD. | |
| NoAutoModeEventId | Event ID for the base event for indicating that auto mode has been disabled. | |
| ODRem1TemperatureEventId | Event ID for the base event for reporting the designator assigned to the remote sensors. | |
| ODRem2TemperatureEventId | Event ID for the base event for reporting the designator assigned to the remote sensors. | |
| ODTemperatureInvalidEventId | Event ID for the base event for indicating that the corresponding when remote temperature sensor isn't reporting valid data. | |
| OfflineHoldEventId | Event ID for the base event for indicating that the thermostat has been taken offline. | |
| OmitLocalTemperatureEventId | Event ID for the base event for reporting the designator assigned to the local (internal) sensors. | |
| OmitRem1TemperatureEventId | Event ID for the base event for reporting the designator assigned to the remote sensors. | |
| OmitRem2TemperatureEventId | Event ID for the base event for reporting the designator assigned to the remote sensors. | |
| Point5CStepsEventId | Event ID for the base event for indicating that the temperature in Celsius will be displayed in half degrees.. | |
| RegTemperatureInvalidEventId | Event ID for the base event for indicating that the corresponding when remote temperature sensor isn't reporting valid data. | |
| Rem1TemperatureInvalidEventId | Event ID for the base event for indicating that the corresponding when remote temperature sensor isn't reporting valid data. | |
| Rem2TemperatureInvalidEventId | Event ID for the base event for indicating that the corresponding when remote temperature sensor isn't reporting valid data. | |
| RemotePageOneDownButtonEventId | Event ID for the base event for indicating that state of the Down button on remote page one has changed. | |
| RemotePageOneUpButtonEventId | Event ID for the base event for indicating that state of the Up button on remote page one has changed. | |
| RemotePageTwoDownButtonEventId | Event ID for the base event for indicating that state of the Down button on remote page two has changed. | |
| RemotePageTwoUpButtonEventId | Event ID for the base event for indicating that state of the Up button on remote page two has changed. | |
| RevSmodeDirEventId | Event ID for the base event for indicating the direction of system mode toggling in response to up/down button presses. | |
| RunFanHeatCallsEventId | Event ID for the base event for indicating that Run Fan in Heat Calls has been enabled. | |
| SlabRem1TemperatureEventId | Event ID for the base event for reporting the designator assigned to the remote sensors. | |
| SlabRem2TemperatureEventId | Event ID for the base event for reporting the designator assigned to the remote sensors. | |
| SlabTemperatureInvalidEventId | Event ID for the base event for indicating that the corresponding when remote temperature sensor isn't reporting valid data. | |
| SysModeAutoFeedbackEventId | Event ID for the base event for reporting the system mode. | |
| SysModeCoolFeedbackEventId | Event ID for the base event for reporting the system mode. | |
| SysModeHeatFeedbackEventId | Event ID for the base event for reporting the system mode. | |
| SysModeOffFeedbackEventId | Event ID for the base event for reporting the system mode. | |
| TemperatureDegCEventId | Event ID for the base event for indicating that the temperature scale Celsius has changed. | |
| TemperatureDegFEventId | Event ID for the base event for indicating that the temperature scale Fahrenheit has changed. | |
| TemperatureDispOffsetEventId | Event ID for the base event for reporting the temperature offset in tenths of a degree. | |
| UseLocalTemperatureEventId | Event ID for the base event for reporting the designator assigned to the local (internal) sensors. | |
| UseRem1TemperatureEventId | Event ID for the base event for reporting the designator assigned to the remote sensors. | |
| UseRem2TemperatureEventId | Event ID for the base event for reporting the designator assigned to the remote sensors. | |
| WideRangeCoolEventId | Event ID for the base event for indicating that wide range cool mode has been enabled.. |