CresnetThermostat Class

Base class for Cresnet thermostats.
Inheritance Hierarchy

Namespace: Crestron.SimplSharpPro.Thermostats
Assembly: Crestron.SimplSharpPro.Thermostats (in Crestron.SimplSharpPro.Thermostats.dll) Version: 2.21.121
Syntax
C#
public class CresnetThermostat : Thermostat

The CresnetThermostat type exposes the following members.

Constructors
 NameDescription
Protected methodCresnetThermostat Base constructor for Cresnet thermostat devices.
Top
Properties
 NameDescription
Public propertyAuto1ptSetpoint Sets the auto1pt setpoint, where 1d = 0.1 degrees. The value is based on the current temperature scale (Fahrenheit or Celsius). The displayed value is rounded to whole or half degrees based on the setting.
(Inherited from Thermostat)
Public propertyAuto1ptSetpointFeedback Reports the active auto1pt setpoint value. This output should be connected to the corresponding setpoint input; otherwise the output will not report the setpoint value.

The BaseEvent event will trigger with Auto1ptSetpointFeedbackEventId.


(Inherited from Thermostat)
Public propertyAuto1ptSetpointMinus Lowers the temperature regulating setpoint for single-point auto only.
Public propertyAuto1ptSetpointPlus Raises the temperature regulating setpoint for single-point auto only.
Public propertyAutoDeadbandFeedback Reports the auto deadband value selected via the "db" option in the Setup menu, where 1d = 0.1 degrees. In dual-setpoint auto mode, this value is the minimum separation between heat and cool setpoints, which prevents the system from toggling back and forth due to overshoot. In single-setpoint auto mode, this value sets the hysteresis used when changing from heat to cool. For example, if the setpoint is 70°F with auto deadband of 2 degrees, the temperature would have to rise to 72°F before running cool, and 68°F before running heat. HZ-THSTAT reports auto mode deadband parameter in 10ths of current unit: Fahrenheit : 20, 30, 40, 50, 60 (F). Celsius : 10, 20, 30 (C).

The BaseEvent event will trigger with AutoDeadbandFeedbackEventId.


(Inherited from Thermostat)
Public propertyColdWeatherComp Indicates that cold weather compensation has been enabled. The output remains true for as long as the mode is enabled. Outdoor low-temperature compensation modifies the humidifier output to prevent condensation on windows in cold weather.
Public propertyConnectedIpList A property containing the list of the ConnectedIpInformation objects which contain information about the devices that are connected to this IP ID. This property is only valid for an ethernet device. If this is not an ethernet device, then this property will return null. If this is an ethernet device, the list will be non-null. It will be empty if no devices are connected. The order of items in this list is not guaranteed.
(Inherited from GenericDevice)
Public propertyCoolAnticipator Reports the cool anticipator values, from 1 to 6. Prevents overshooting the set temperature. A lower number signifies more frequent cycles and faster response (tighter regulation), while a higher number signifies less frequent cycles and slower response (looser regulation).
Public propertyCoolCallFeedbacks Returns a collection of components that indicate when the system is calling for cooling.

The ClimateControlComponentCallChange event will trigger with ClimateControlComponent object.


(Inherited from Thermostat)
Public propertyCoolSetpoint Sets the cool setpoint, where 1d = 0.1 degrees. The value is based on the current temperature scale (Fahrenheit or Celsius). The displayed value is rounded to whole or half degrees based on the setting.
(Inherited from Thermostat)
Public propertyCoolSetpointFeedback Reports the active cool setpoint value. This output should be connected to the corresponding setpoint input; otherwise the output will not report the setpoint value.

The BaseEvent event will trigger with CoolSetpointFeedbackEventId.


(Inherited from Thermostat)
Public propertyCoolSetpointMinus Lowers the temperature regulating setpoint for cool-only.
Public propertyCoolSetpointPlus Raises the temperature regulating setpoint for cool-only.
Public propertyCode exampleDescription Get/Set the description of this device.
(Inherited from GenericBase)
Public propertyDispGlobalPage Indicates that the Global page (consisting of the Global Send button) has been enabled for display on the thermostat LCD. The output remains true for as long as the page is enabled.
Public propertyDisposed Property to indicate if the device has been disposed.
(Inherited from GenericDevice)
Public propertyDispOutdoorPage Indicates that the Global page (consisting of the Global Send button) has been enabled for display on the thermostat LCD. The output remains true for as long as the page is enabled.
Public propertyDispRemoteBtnPage1 Indicates that Remote page 1 has been enabled for display. The output remains true for as long as the page is enabled. The thermostats provide two Remote pages that can be used to trigger non-HVAC functions such as AV control, lighting, or alarm activation.
Public propertyDispRemoteBtnPage2 Indicates that Remote page 2 has been enabled for display. The output remains true for as long as the page is enabled. The thermostats provide two Remote pages that can be used to trigger non-HVAC functions such as AV control, lighting, or alarm activation.
Public propertyDualSetpointsAutoMode Indicates that dual-point auto mode has been enabled. The output remains true for as long as the mode is enabled. Auto mode can be enabled or disabled from the Setup menu.
Public propertyFanAuto Sets the fan to auto mode. In Auto mode, the fan runs only when the system calls.
Public propertyFanAutoFeedback Reports if the fan is currently in auto mode.
Public propertyFanOn Sets the fan to on mode. In On mode, the fan runs continually.
Public propertyFanOnFeedback Reports if the fan is currently in on mode.
Public propertyFrontPanelLockout Locks out the four hard pushbuttons on the thermostat for as long as the input remains true. In this mode, pressing the buttons will have no effect. Automatically disabled in case of system error or failure.
Public propertyGlobalPress Briefly pulses whenever the Send button of the Global Update page is pressed. This signal can be tied to logic in the program to trigger functions such as global updates of temperature or humidity values.
Public propertyHeatAnticipator Reports the heat anticipator values, from 1 to 6. Prevents overshooting the set temperature. A lower number signifies more frequent cycles and faster response (tighter regulation), while a higher number signifies less frequent cycles and slower response (looser regulation).
Public propertyHeatCallFeedbacks Returns a collection of components that indicate when the system is calling for heat.

The ClimateControlComponentCallChange event will trigger with ClimateControlComponent object.


(Inherited from Thermostat)
Public propertyHeatSetpoint Sets the heat setpoint, where 1d = 0.1 degrees. The value is based on the current temperature scale (Fahrenheit or Celsius). The displayed value is rounded to whole or half degrees based on the setting.
(Inherited from Thermostat)
Public propertyHeatSetpointFeedback Reports the active heat setpoint value. This output should be connected to the corresponding setpoint input; otherwise the output will not report the setpoint value.

The BaseEvent event will trigger with HeatSetpointFeedbackEventId.


(Inherited from Thermostat)
Public propertyHeatSetpointMinus Lowers the temperature regulating setpoint for heat-only.
Public propertyHeatSetpointPlus Raises the temperature regulating setpoint for heat-only.
Public propertyHoldOff Turns off the Hold function.
Public propertyHoldOn Turns on the Hold function.
Public propertyID Property to get the ID of the device.
(Inherited from GenericDevice)
Public propertyIsOnline Property to get the current online state of the device.
(Inherited from GenericDevice)
Public propertyLCDContrast Reports the LCD screen contrast. Values range from 1 (lightest) to 10 (darkest).
Public propertyLocalTemperatureFeedback Reports the local temperature reported by the Local sensor. Only enabled when EnableSensorOutputs is enabled. This property is supported by "HZThstat" not supported by "DinThstat".

The TemperatureChange event will trigger with temperatureType and newTemperature.


(Inherited from Thermostat)
Public propertyLocalTemperatureInvalid Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent.
Public propertyMainScrnObNA Reports that NA will be displayed under the current temperature on the Main page of the thermostat LCD.
Public propertyMainScrnObOutdoor Reports that outdoor will be displayed under the current temperature on the Main page of the thermostat LCD.
Public propertyMainScrnObSlabTemperature Reports that slab will be displayed under the current temperature on the Main page of the thermostat LCD.
Public propertyMsgField Sends text string to the Messages page of the thermostat LCD. Displayed text is limited to approximately 20 characters per line (including spaces) to a maximum of four lines. The thermostat supports word wrap and auto-hyphenation within the 20 characters/spaces per line maximum. (Carriage returns will force a line change.)
Public propertyMsgIconOn Alternately flashes the text "View Msg" with "Online/Hold, Net Fault" on the Main page of the thermostat LCD, for as long as the input remains true. This alerts the user to check for a displayed message on the Messages page of the thermostat LCD.
Public propertyMsgWaiting Indicates that text has been sent to the Messages page of the thermostat LCD, via the MsgField input. The output remains true until the user presses the Clear button on the Messages page.
Public propertyName Get the name of this device.
(Inherited from GenericBase)
Public propertyNoAutoMode Indicates that auto mode has been disabled. The output remains true for as long as auto mode is off. Auto mode can be enabled or disabled from the Setup menu.
Public propertyODRem1Temperature Reports the designator assigned to the remote sensors.
Public propertyODRem2Temperature Reports the designator assigned to the remote sensors.
Public propertyODTemperatureInvalid Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent.
Public propertyOfflineHold Indicates that the thermostat has been taken offline. In this mode, the thermostat is "on hold" and data flows one way, from the thermostat to Cresnet. All Cresnet commands to the thermostat are blocked except for the Hold Off command. While the thermostat is "on hold" it buffers all setpoint and mode changes (except for up/down inputs). The setpoints and mode inputs will take effect immediately when the hold is released. Remains true for as long as the thermostat is offline.
Public propertyOmitLocalTemperature Reports if temperature is assigned to the local (internal) sensors. The CHV-TSTAT provides one internal temperature sensor; the CHV-THSTAT provides internal sensors for temperature and humidity. Each sensor must be designated as Use or Omit. Readings from local and remote sensors that have the same designator are averaged together. Thus two temperature sensors set to Use are averaged for the air temperature control, while two humidity sensors set to Use are averaged to determine the humidity. A sensor designated as "Omit" signifies that the reading will not be included in such averaging.
Public propertyOmitRem1Temperature Reports the designator assigned to the remote sensors.
Public propertyOmitRem2Temperature Reports the designator assigned to the remote sensors.
Public propertyOutdoorTemperatureFeedback Sends the current outdoor temperature to the thermostat. This input should only be used for heatpump/dual fuel balance point systems, not heat/cool system types. The value should be sent in tenths of a degree (1d = 0.1 degrees) based on the current temperature scale (Fahrenheit or Celsius). For example, if the outdoor temperature is 45.3°F, the value should be 453.

The TemperatureChange event will trigger with temperatureType and newTemperature.


(Inherited from Thermostat)
Public propertyOutdoorTemperatureInput Sends the current outdoor temperature to the thermostat. This input should only be used for heatpump/dual fuel balance point systems, not heat/cool system types. The value should be sent in tenths of a degree (1d = 0.1 degrees) based on the current temperature scale (Fahrenheit or Celsius). For example, if the outdoor temperature is 45.3°F, the value should be 453d.
(Inherited from Thermostat)
Public propertyParent The parent that a given object was added to.
(Inherited from GenericBase)
Public propertyPoint5CSteps Indicates that the temperature in Celsius will be displayed in half degrees.
Public propertyRegisterable Property to indicate that this device can be registered.
(Inherited from GenericDevice)
Public propertyRegistered Property to get the current registration state of the device.
(Inherited from GenericDevice)
Public propertyRegistrationFailureReason Property to get the Registration Failure Reason, this will match the return value from the call to register.
(Inherited from GenericDevice)
Public propertyRegTemperatureInvalid Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent.
Public propertyRegulationTemperatureFeedback Reports displayed temperature, which can be the Local temperature or the Remote 1 temperature, or the average of Local and Remote 1, based on the option selected in the Setup menu (Local = i; Remote 1 = r; Average = ir).

The TemperatureChange event will trigger with temperatureType and newTemperature.


(Inherited from Thermostat)
Public propertyRem1TemperatureInvalid Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent.
Public propertyRem2TemperatureInvalid Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent.
Public propertyRemote1TemperatureFeedback Reports the temperature reported by the Remote 1 sensor. Only enabled when EnableSensorOutputs is enabled.

The TemperatureChange event will trigger with temperatureType and newTemperature.


(Inherited from Thermostat)
Public propertyRemote2TemperatureFeedback Reports the local temperature reported by the Remote 2 sensor. Only enabled when EnableSensorOutputs is enabled.

The TemperatureChange event will trigger with temperatureType and newTemperature.


(Inherited from Thermostat)
Public propertyRemotePageOneDownButton Indicates the state of the Down button on Remote Page one of the thermostat LCD. The output remains true for as long as the button is pressed. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC "remote" functions such as AV control, lighting, or alarm activation.
Public propertyRemotePageOneDownButtonLabel Sends text label for display next to the Down button on Remote Page one of the thermostat LCD. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC functions such as AV control, lighting, or alarm activation.
Public propertyRemotePageOneUpButton Indicates the state of the Up button on Remote Page one of the thermostat LCD. The output remains true for as long as the button is pressed. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC "remote" functions such as AV control, lighting, or alarm activation.
Public propertyRemotePageOneUpButtonLabel Sends text label for display next to the Up button on Remote Page one of the thermostat LCD. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC functions such as AV control, lighting, or alarm activation.
Public propertyRemotePageTwoDownButton Indicates the state of the Down button on Remote Page two of the thermostat LCD. The output remains true for as long as the button is pressed. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC "remote" functions such as AV control, lighting, or alarm activation.
Public propertyRemotePageTwoDownButtonLabel Sends text label for display next to the Down button on Remote Page two of the thermostat LCD. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC functions such as AV control, lighting, or alarm activation.
Public propertyRemotePageTwoUpButton Indicates the state of the Up button on Remote Page two of the thermostat LCD. The output remains true for as long as the button is pressed. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC "remote" functions such as AV control, lighting, or alarm activation.
Public propertyRemotePageTwoUpButtonLabel Sends text label for display next to the Up button on Remote Page two of the thermostat LCD. The thermostat LCD provides two Remote pages in which the Up and Down pushbuttons operate as remote function buttons. In this mode the buttons can trigger non-HVAC functions such as AV control, lighting, or alarm activation.
Public propertyRevSmodeDir Indicates the direction of system mode toggling in response to up/down button presses. The output becomes true when the Setup option for "Reverse System Mode Direction" is set to "Y". In this mode, the UP button moves the mode select box to the right instead of to the left.
Public propertyRunBacklight Turns on the thermostat's backlight for 8 seconds.
Public propertyRunFanHeatCalls Indicates that Run Fan in Heat Calls has been enabled. The output remains true for as long as the mode is enabled. Run Fan in Heat Calls is a device setting that activates the fan output with W1/W2 heat calls. Does not enable operation on slab systems on the slab (W1) call.
Protected propertySIMPLDeviceImplementation Internal protected member used for actual device control.
(Inherited from GenericDevice)
Public propertySlabRem1Temperature Reports the designator assigned to the remote sensors.
Public propertySlabRem2Temperature Reports the designator assigned to the remote sensors.
Public propertySlabTemperature Reports the temperature reading of any remote sensor set to "Slab", in tenths of a degree. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. If more than one sensor is set to "Slab", this is the mean slab temperature. Sensors are set to Use, Omit, OD (Outdoor) or Slab via the setup menus on the thermostat.
Public propertySlabTemperatureInvalid Indicates that the corresponding when remote temperature/humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent.
Public propertySysModeAuto Selects auto mode (auto selects heat or cool).
Public propertySysModeAutoFeedback Reports if auto mode is the current system mode.
Public propertySysModeCool Selects cool-only mode.
Public propertySysModeCoolFeedback Reports if cool mode is the current system mode.
Public propertySysModeHeat Selects heat-only mode.
Public propertySysModeHeatFeedback Reports if heat mode is the current system mode.
Public propertySysModeOff Selects off mode (no HVAC operation).
Public propertySysModeOffFeedback Reports if off mode is the current system mode.
Public propertyTemperatureDegC Indicates that Celcius is the temperature scale.
Public propertyTemperatureDegF Indicates that Fahrenheit is the temperature scale.
Public propertyTemperatureDispOffset Reports the temperature offset in tenths of a degree. The offset is the number of degrees added or subtracted from the actual sensed temperature. The scale (Fahrenheit or Celsius) is based on the current setting in the unit. Values are as follows: Fahrenheit: -60 to +60 (-6˚ to +6˚F) Celsius: -30 to +30 (-3˚ to +3˚C) Half degrees Celsius mode: -35 to +35 (-3.5˚to +3.5˚C) This temperature offset changes the actual regulated temperature, not just the displayed temperature. The offset is set to "0" as shipped from the factory.
Public propertyType Property to determine to type of device this is.
(Inherited from GenericDevice)
Public propertyUnRegistrationFailureReason Property to get the Unregistration Failure Reason, this will match the return value from the call to unregister.
(Inherited from GenericDevice)
Public propertyUseLocalTemperature Reports if temperature is assigned to the local (internal) sensors. The CHV-TSTAT provides one internal temperature sensor; the CHV-THSTAT provides internal sensors for temperature and humidity. Each sensor must be designated as Use or Omit. Readings from local and remote sensors that have the same designator are averaged together. Thus two temperature sensors set to Use are averaged for the air temperature control, while two humidity sensors set to Use are averaged to determine the humidity. A sensor designated as "Omit" signifies that the reading will not be included in such averaging.
Public propertyUseRem1Temperature Reports the designator assigned to the remote sensors.
Public propertyUseRem2Temperature Reports the designator assigned to the remote sensors.
Public propertyUserSpecifiedObject Can be assigned anything that user wants.
(Inherited from GenericBase)
Public propertyWideRangeCool Indicates that wide range cool mode has been enabled. The output remains true for as long as the mode is enabled. Wide range cool extends the cool setpoint range to the full auto range of 38° to 99°F, or 3° to 37°C. This is suitable for wine cellars or other colder chilling processes.
Protected propertyXioEndpointStubSIMPLDevice The SIMPL "stub" Device that the XiO Director creates for an endpoint to send the 1C/0E to the correct place in hierarchy.
(Inherited from GenericDevice)
Top
Methods
 NameDescription
Protected method_CurrentSystemStateSlot_CueChange Method that handles CurrentSystemState slot events.
(Inherited from Thermostat)
Protected method_DisplayFunctions_CueChange Method that handles DisplayFunctions slot events.
Protected method_HeatCoolControlSlot_CueChange Method that handles HeatCoolControl slot events.
(Inherited from Thermostat)
Protected method_SystemConfigurationSlot_CueChange Method that handles SystemConfiguration slot events.
(Inherited from Thermostat)
Public methodDispose Clean up of resources.
(Inherited from GenericBase)
Protected methodDispose(Boolean) Method to perform the actual disposing of the device.
(Inherited from GenericDevice)
Public methodEqualsDetermines whether the specified object is equal to the current object.
(Inherited from Object)
Protected methodFinalize Destructor of the device.
(Inherited from GenericDevice)
Public methodGetHashCodeServes as the default hash function.
(Inherited from Object)
Public methodGetTypeGets the Type of the current instance.
(Inherited from Object)
Protected methodInitializeDevice Method used to initialize cresnet thermostats.
Protected methodMemberwiseCloneCreates a shallow copy of the current Object.
(Inherited from Object)
Protected methodOnBaseEvent(Int32) Protected member used to fire the BaseEvent with the default extended information.
(Inherited from GenericBase)
Protected methodOnBaseEvent(Int32, UInt16) Protected member used to fine the BaseEvent with extended event information.
(Inherited from GenericBase)
Protected methodOnClimateControlComponentEvent Method to fire the climate control component change event.
(Inherited from Thermostat)
Protected methodOnFanCallEvent Method to fire the fan event.
(Inherited from Thermostat)
Protected methodOnTemperatureChange Method to fire the temperature change event.
(Inherited from Thermostat)
Public methodRegister Register this device with the system.
(Inherited from GenericDevice)
Public methodToString Return the name of the device.
(Inherited from GenericDevice)
Public methodUnRegister Unregister this device with the system. This function can not be called from the device's own SigChange event handler.

On successful unregistration, if this device supports the OnlineStatusChange event, it will trigger indicating the device when offline.


(Inherited from GenericDevice)
Top
Events
 NameDescription
Public eventBaseEvent Generic base event, triggered when the there are no other handlers available for a specific EventID.
(Inherited from GenericBase)
Public eventClimateControlComponentCallChange Event fired when a climate component change was received from the device.
(Inherited from Thermostat)
Public eventFanCallChange Event fired when a fan change was received from the device.
(Inherited from Thermostat)
Public eventIpInformationChange Event that tells what IP Address is connected/disconnected from an IP ID for a non-UDP device. This is only valid for an Ethernet device. An exception will be thrown if it is not.
(Inherited from GenericDevice)
Public eventOnlineStatusChange Event triggered when the Online status of the device changes.
(Inherited from GenericDevice)
Public eventTemperatureChange Event fired when a temperature change was received from the device.
(Inherited from Thermostat)
Top
Fields
 NameDescription
Protected field_CoolCallFeedbacks Returns a collection of components that indicate when the system is calling for cooling.
(Inherited from Thermostat)
Protected field_CurrentSystemStateSlot Current system state slot device.
(Inherited from Thermostat)
Protected field_HeatCallFeedbacks A collection of components that indicate when the system is calling for heat.
(Inherited from Thermostat)
Protected field_HeatCoolControlSlot Heat/cool control slot device.
(Inherited from Thermostat)
Protected field_SystemConfigurationSlot System configuration slot device.
(Inherited from Thermostat)
Public fieldStatic memberColdWeatherCompEventId Event ID for the base event for indicating that cold weather compensation has been enabled.
Public fieldStatic memberCoolAnticipatorEventId Event ID for the base event for reporting the cool anticipator values, from 1 to 6. Prevents overshooting the set temperature..
Public fieldStatic memberDispGlobalPageEventId Event ID for the base event for .
Public fieldStatic memberDispOutdoorPageEventId Event ID for the base event for indicating that the Outdoor page has been enabled for display on the thermostat LCD.
Public fieldStatic memberDispRemoteBtnPage1EventId Event ID for the base event for indicating that Remote page 1 has been enabled for display.
Public fieldStatic memberDispRemoteBtnPage2EventId Event ID for the base event for indicating that Remote page 2 has been enabled for display.
Public fieldStatic memberDualSetpointsAutoModeEventId Event ID for the base event for indicating that dual-point auto mode has been enabled.
Public fieldStatic memberFanAutoEventId Event ID for the base event for reporting the fan mode.
Public fieldStatic memberFanOnFeedbackEventId Event ID for the base event for reporting the fan mode.
Public fieldStatic memberGlobalPressEventId Event ID for the base event for indicating that the Send button of the Global Update page was pressed.
Public fieldStatic memberHeatAnticipatorEventId Event ID for the base event for reporting the heat anticipator values, from 1 to 6. Prevents overshooting the set temperature..
Public fieldStatic memberLCDContrastEventId Event ID for the base event for reporting the LCD screen contrast..
Public fieldStatic memberLocalTemperatureInvalidEventId Event ID for the base event for indicating that the corresponding when remote temperature sensor isn't reporting valid data.
Public fieldStatic memberMainScrnObNAEventId Event ID for the base event for reporting if NA will be the reading that will be displayed under the current temperature on the Main page of the thermostat LCD.
Public fieldStatic memberMainScrnObOutdoorEventId Event ID for the base event for reporting if Outdoor will be the reading that will be displayed under the current temperature on the Main page of the thermostat LCD.
Public fieldStatic memberMainScrnObSlabTemperatureEventId Event ID for the base event for reporting if SlabTemp will be the reading that will be displayed under the current temperature on the Main page of the thermostat LCD.
Public fieldStatic memberMsgWaitingEventId Event ID for the base event for indicating that text has been sent to the Messages page of the thermostat LCD.
Public fieldStatic memberNoAutoModeEventId Event ID for the base event for indicating that auto mode has been disabled.
Public fieldStatic memberODRem1TemperatureEventId Event ID for the base event for reporting the designator assigned to the remote sensors.
Public fieldStatic memberODRem2TemperatureEventId Event ID for the base event for reporting the designator assigned to the remote sensors.
Public fieldStatic memberODTemperatureInvalidEventId Event ID for the base event for indicating that the corresponding when remote temperature sensor isn't reporting valid data.
Public fieldStatic memberOfflineHoldEventId Event ID for the base event for indicating that the thermostat has been taken offline.
Public fieldStatic memberOmitLocalTemperatureEventId Event ID for the base event for reporting the designator assigned to the local (internal) sensors.
Public fieldStatic memberOmitRem1TemperatureEventId Event ID for the base event for reporting the designator assigned to the remote sensors.
Public fieldStatic memberOmitRem2TemperatureEventId Event ID for the base event for reporting the designator assigned to the remote sensors.
Public fieldStatic memberPoint5CStepsEventId Event ID for the base event for indicating that the temperature in Celsius will be displayed in half degrees..
Public fieldStatic memberRegTemperatureInvalidEventId Event ID for the base event for indicating that the corresponding when remote temperature sensor isn't reporting valid data.
Public fieldStatic memberRem1TemperatureInvalidEventId Event ID for the base event for indicating that the corresponding when remote temperature sensor isn't reporting valid data.
Public fieldStatic memberRem2TemperatureInvalidEventId Event ID for the base event for indicating that the corresponding when remote temperature sensor isn't reporting valid data.
Public fieldStatic memberRemotePageOneDownButtonEventId Event ID for the base event for indicating that state of the Down button on remote page one has changed.
Public fieldStatic memberRemotePageOneUpButtonEventId Event ID for the base event for indicating that state of the Up button on remote page one has changed.
Public fieldStatic memberRemotePageTwoDownButtonEventId Event ID for the base event for indicating that state of the Down button on remote page two has changed.
Public fieldStatic memberRemotePageTwoUpButtonEventId Event ID for the base event for indicating that state of the Up button on remote page two has changed.
Public fieldStatic memberRevSmodeDirEventId Event ID for the base event for indicating the direction of system mode toggling in response to up/down button presses.
Public fieldStatic memberRunFanHeatCallsEventId Event ID for the base event for indicating that Run Fan in Heat Calls has been enabled.
Public fieldStatic memberSlabRem1TemperatureEventId Event ID for the base event for reporting the designator assigned to the remote sensors.
Public fieldStatic memberSlabRem2TemperatureEventId Event ID for the base event for reporting the designator assigned to the remote sensors.
Public fieldStatic memberSlabTemperatureInvalidEventId Event ID for the base event for indicating that the corresponding when remote temperature sensor isn't reporting valid data.
Public fieldStatic memberSysModeAutoFeedbackEventId Event ID for the base event for reporting the system mode.
Public fieldStatic memberSysModeCoolFeedbackEventId Event ID for the base event for reporting the system mode.
Public fieldStatic memberSysModeHeatFeedbackEventId Event ID for the base event for reporting the system mode.
Public fieldStatic memberSysModeOffFeedbackEventId Event ID for the base event for reporting the system mode.
Public fieldStatic memberTemperatureDegCEventId Event ID for the base event for indicating that the temperature scale Celsius has changed.
Public fieldStatic memberTemperatureDegFEventId Event ID for the base event for indicating that the temperature scale Fahrenheit has changed.
Public fieldStatic memberTemperatureDispOffsetEventId Event ID for the base event for reporting the temperature offset in tenths of a degree.
Public fieldStatic memberUseLocalTemperatureEventId Event ID for the base event for reporting the designator assigned to the local (internal) sensors.
Public fieldStatic memberUseRem1TemperatureEventId Event ID for the base event for reporting the designator assigned to the remote sensors.
Public fieldStatic memberUseRem2TemperatureEventId Event ID for the base event for reporting the designator assigned to the remote sensors.
Public fieldStatic memberWideRangeCoolEventId Event ID for the base event for indicating that wide range cool mode has been enabled..
Top

Version Information

.NET

Supported in: 6.0

.NET Compact Framework

Supported in: 3.5
See Also