Hz |
The HzThstat type exposes the following members.
| Name | Description | |
|---|---|---|
| AnyFcuSysTypeFeedback |
Property to inidicate the system type is any of the FCU types
True: System is FCU type, False: System is not FCU type
The BaseEvent event will trigger with AnyFcuSystemTypeEventId object. | |
| AnyFloorHeatSystemTypeFeedback |
Property to indicate if any system type using floor radiant heat is defined (can be both floor warming and space heating via floor radiant).
true = A system type using floor radiant heat is defined; false = No system type using floor radiant heat is defined
The BaseEvent event will trigger with AnyFloorHeatSystemTypeFeedbackEventId. (Inherited from DinThstat) | |
| AnyHeatpumpSystemTypeFeedback |
Property to indicate if any heat pump control logic is used.
true = A heat pump control logic is used; false = No heat pump control logic is used
The BaseEvent event will trigger with AnyHeatpumpSystemTypeFeedbackEventId. (Inherited from DinThstat) | |
| AnySpaceSystemTypeFeedback |
Property to indicate that if any space system type defined.
true = A space system is defined; false = No space system is defined
The BaseEvent event will trigger with AnySpaceSystemTypeFeedbackEventId. (Inherited from DinThstat) | |
| Auto1ptSetpoint |
Sets the auto1pt setpoint, where 1d = 0.1 degrees.
The value is based on the current temperature scale (Fahrenheit or Celsius).
The displayed value is rounded to whole or half degrees based on the setting.
(Inherited from Thermostat) | |
| Auto1ptSetpointFeedback |
Reports the active auto1pt setpoint value.
This output should be connected to the corresponding setpoint input; otherwise the output will not report the setpoint value.
The BaseEvent event will trigger with Auto1ptSetpointFeedbackEventId. (Inherited from Thermostat) | |
| AutoDeadbandFeedback |
Reports the auto deadband value selected via the "db" option in the Setup menu, where 1d = 0.1 degrees.
In dual-setpoint auto mode, this value is the minimum separation between heat and cool setpoints,
which prevents the system from toggling back and forth due to overshoot.
In single-setpoint auto mode, this value sets the hysteresis used when changing from heat to cool.
For example, if the setpoint is 70°F with auto deadband of 2 degrees,
the temperature would have to rise to 72°F before running cool, and 68°F before running heat.
HZ-THSTAT reports auto mode deadband parameter in 10ths of current unit:
Fahrenheit : 20, 30, 40, 50, 60 (F).
Celsius : 10, 20, 30 (C).
The BaseEvent event will trigger with AutoDeadbandFeedbackEventId. (Inherited from Thermostat) | |
| AuxHeatCallFeedbacks |
Returns a collection of components that indicate when the system is calling for auxiliary heat.
The ClimateControlComponentCallChange event will trigger with ClimateControlComponent object. (Inherited from DinThstat) | |
| AuxHeatCallShortCycleTimeoutHoldOffFeedback | Obsolete. Property to indicate Aux heat call held off by short cycle timeout. True: Indicates system call is being held off by short-cycle protection, False : Not Held. | |
| AuxInputActiveFeedback |
Indicates that the general-purpose opto-isolated input has voltage applied.
This property is not supported by HZ-THSTAT.
The BaseEvent event will trigger with AuxInputActiveFeedbackEventId object. (Inherited from DinThstat) | |
| ConnectedIpList |
A property containing the list of the ConnectedIpInformation objects which contain information about the devices that are connected to this IP ID.
This property is only valid for an ethernet device. If this is not an ethernet device, then this property will return null.
If this is an ethernet device, the list will be non-null. It will be empty if no devices are connected.
The order of items in this list is not guaranteed.
(Inherited from GenericDevice) | |
| CoolCallFeedbacks |
Returns a collection of components that indicate when the system is calling for cooling.
The ClimateControlComponentCallChange event will trigger with ClimateControlComponent object. (Inherited from Thermostat) | |
| CoolCallShortCycleTimeoutHoldOffFeedback | Obsolete. Property to indicate Cool call held off by short cycle timeout. True: Indicates system call is being held off by short-cycle protection, False : Not Held. | |
| CoolSetpoint |
Sets the cool setpoint, where 1d = 0.1 degrees.
The value is based on the current temperature scale (Fahrenheit or Celsius).
The displayed value is rounded to whole or half degrees based on the setting.
(Inherited from Thermostat) | |
| CoolSetpointFeedback |
Reports the active cool setpoint value.
This output should be connected to the corresponding setpoint input; otherwise the output will not report the setpoint value.
The BaseEvent event will trigger with CoolSetpointFeedbackEventId. (Inherited from Thermostat) | |
| DehumidityCallFeedbacks |
Returns a collection of components that indicate when the system is making a dehumidity call.
The ClimateControlComponentCallChange event will trigger with ClimateControlComponent object. (Inherited from DinThstat) | |
| Description |
Get/Set the description of this device.
(Inherited from GenericBase) | |
| DinUnitUiLockout |
Property to lock out operation of the UI on the DIN-THSTAT unit.
(Inherited from DinThstat) | |
| DisplayMessage |
Property to set a string for displaying brief messages on remote UI.
(Inherited from DinThstat) | |
| DisplayUnit |
Property to accept an enumeration for defining temperature unit format.
(Inherited from DinThstat) | |
| DisplayUnitFeedback |
Property to report the enumeration for defining temperature unit format.
The BaseEvent event will trigger with DisplayUnitFeedbackEventId for this property. (Inherited from DinThstat) | |
| Disposed |
Property to indicate if the device has been disposed.
(Inherited from GenericDevice) | |
| DualSetpointsAutoModeFeedback |
Property to indicate if auto mode uses separate heat and cool SP’s (instead of the single SP format).
The BaseEvent event will trigger with DualSetpointsAutoModeFeedbackEventId for this property. (Inherited from DinThstat) | |
| ExtenderUiStatusReservedSigs |
Property to access the UI status functionality of the HZ-Thstat.
This property will trigger DeviceExtenderSigChange event. | |
| FanCallFeedback |
Indicates that the fan is running.
The FanCallChange event will trigger with ThermostatFanSpeed and ThermostatFanState. (Inherited from DinThstat) | |
| FanCallHighFeedback |
Property to indicate if fan is running on the high setting.
True: Fan is running on the high setting, False : Fan is not running on the high setting.
The FanCallChange event will trigger with ThermostatFanSpeed and ThermostatFanState. | |
| FanCallLowFeedback |
Property to indicate if fan is running on the low setting.
True: Fan is running on the low setting, False : Fan is not running on the low setting.
The FanCallChange event will trigger with ThermostatFanSpeed and ThermostatFanState. | |
| FanCallMediumFeedback |
Property to indicate if fan is running on the medium setting.
True: Fan is running on the medium setting, False : Fand is not running on the medium setting.
The FanCallChange event will trigger with ThermostatFanSpeed and ThermostatFanState. | |
| FanCallShortCycleTimeoutHoldOffFeedback | Obsolete. Property to indicate Fan call held off by short cycle timeout. True: Indicates system call is being held off by short-cycle protection, False : Not Held. | |
| FanCirculateLowCallFeedback |
Property to indicate if fan is running for periodic circulation purpose(low duty cycle).
True: Active (low duty cycle), False : Not active.
The FanCallChange event will trigger with ThermostatFanSpeed and ThermostatFanState. | |
| FanCirculateMediumCallFeedback |
Property to indicate if fan is running for periodic circulation purpose(medium duty cycle).
True: Active (Medium duty cycle), False : Not active.
The FanCallChange event will trigger with ThermostatFanSpeed and ThermostatFanState. | |
| FanCirculationCallFeedback |
Indicates that the fan is circulating.
The FanCallChange event will trigger with ThermostatFanSpeed and ThermostatFanState. (Inherited from DinThstat) | |
| FanMode |
Sets the fan mode.
(Inherited from DinThstat) | |
| FanModeFeedback |
Reports the commanded/current fan mode.
The BaseEvent event will trigger with FanModeFeedbackEventId. (Inherited from DinThstat) | |
| FanRunTimeHoursFeedback |
Property to indicate cumulative fan runtime in hours since last reset.
This value is used for fitler interval timing. (value gets reset via ResetFanRunTime input)
The BaseEvent event will trigger with FanRunTimeHoursFeedbackEventId. | |
| FanSpeed | Sets the fan speed. | |
| FanSpeedFeedback |
Reports the commanded/current fan speed.
The BaseEvent event will trigger with FanSpeedFeedbackEventId. | |
| FcuAutoChangeoverCoolDetectedFeedback |
Property to indicate when a 2-pipe heat/cool fan coil unit system type detects the supply pipe is providing cooling
True: The fan coil unit system type detectss the supply pipe has switched from providing heating to cooling, False : The fan coil unit system type no longer detects the supply pipe switching from heating to cooling.
The BaseEvent event will trigger with FcuAutoChangeoverCoolDetectedEventId object. | |
| FcuAutoChangeoverHeatDetectedFeedback |
Property to indicate when a 2-pipe heat/cool fan coil unit system type detects the supply pipe is providing heating
True: The fan coil unit system type detectss the supply pipe has switched from providing cooling to heating, False : The fan coil unit system type no longer detects the supply pipe switching from cooling to heating.
The BaseEvent event will trigger with FcuAutoChangeoverHeatDetectedEventId object. | |
| FcuAutoChangeoverTemperatureFeedback |
Property to report the the temperature of the sensor defined as the FCU 2-pipe heat/cool supply pipe temperature sensor.
This sensor is used to detect what system mode the building supply water is operating in.
Value is reported in 10ths of the current temperature unit
The BaseEvent event will trigger with FcuAutoChangeoverTemperatureEventId object. | |
| FcuAvailableFanSpeedsMaskFeedback |
Property to inidicate the available fan speeds for FCU system types
The BaseEvent event will trigger with FcuAvailableFanSpeedsMaskEventId object. | |
| FcuFanSpeedStagingEnabledFeedback |
Property to indicate the status of automatic staging of fan speeds for FCU systems
Note this may report high even when system type is not an FCU type.
True: Automatic staging of fan speeds is enabled, False: automatic staging of fan speeds is disabled
The BaseEvent event will trigger with FcuFanSpeedStagingEnabledEventId object. | |
| FcuSysIs2pipeFeedback |
Property to inidicate the system type is a 2-pipe FCY system.
True: System is 2-pipe FCU, False: System is 4-pipe FCU or non-FCU
The BaseEvent event will trigger with FcuSystemIs2pipeEventId object. | |
| FloorTemperatureFeedback |
Reports the current floor temperature in tenths of current unit.
This is like the “regulation” values from other slots, which can be an average of more than one floor sensor.
However, it is reported for any floor radiant system configuration, even if the type does not control the floor temperature.
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from DinThstat) | |
| FloorWarmingCallFeedbacks |
Returns a collection of components that indicate when the system is making a floor warming call.
The ClimateControlComponentCallChange event will trigger with ClimateControlComponent object. (Inherited from DinThstat) | |
| FloorWarmingCallShortCycleTimeoutHoldOffFeedback | Obsolete. Property to indicate Floor warming call held off by short cycle timeout. True: Indicates system call is being held off by short-cycle protection, False : Not Held. | |
| FloorWarmingMode |
Property to set the floor warming mode.
(Inherited from DinThstat) | |
| FloorWarmingModeFeedback |
Property to report the floor warming system mode.
The BaseEvent event will trigger with FloorWarmingModeFeedbackEventId. (Inherited from DinThstat) | |
| FloorWarmingSetpoint |
Property to set the floor warming setpoint value in tenths of the current unit.
(Inherited from DinThstat) | |
| FloorWarmingSetpointFeedback |
Reports the current floor warming setpoint value in tenths of the current unit.
The BaseEvent event will trigger with FloorWarmingSetpointFeedbackEventId. (Inherited from DinThstat) | |
| FloorWarmingSystemTypeFeedback |
Property to indicate if a floor warming system type is defined (independent signal; floor warming can be controlled separately from space).
true = A floor warming system type is defined; false = No floor warming system type is defined
The BaseEvent event will trigger with FloorWarmingSystemTypeFeedbackEventId. (Inherited from DinThstat) | |
| FullSetupData |
Property to store full setup configuration for advanced debug or remote configuration.
(Inherited from DinThstat) | |
| FullSetupDataFeedback |
Property to read full setup configuration for advanced debug or remote configuration.
FullSetupDataFeedback will trigger the event FullSetupDataFeedbackEventId. (Inherited from DinThstat) | |
| HeatCallFeedbacks |
Returns a collection of components that indicate when the system is calling for heat.
The ClimateControlComponentCallChange event will trigger with ClimateControlComponent object. (Inherited from Thermostat) | |
| HeatCallShortCycleTimeoutHoldOffFeedback | Obsolete. Property to indicate Heat call held off by short cycle timeout. True: Indicates system call is being held off by short-cycle protection, False : Not Held. | |
| HeatSetpoint |
Sets the heat setpoint, where 1d = 0.1 degrees.
The value is based on the current temperature scale (Fahrenheit or Celsius).
The displayed value is rounded to whole or half degrees based on the setting.
(Inherited from Thermostat) | |
| HeatSetpointFeedback |
Reports the active heat setpoint value.
This output should be connected to the corresponding setpoint input; otherwise the output will not report the setpoint value.
The BaseEvent event will trigger with HeatSetpointFeedbackEventId. (Inherited from Thermostat) | |
| HumidistatCallShortCycleTimeoutHoldOffFeedback | Obsolete. Property to indicate Humidistat call held off by short cycle timeout. True: Indicates system call is being held off by short-cycle protection, False : Not Held. | |
| HumidistatEnabledFeedback |
Property to indicate if the humidistat operation is available. This is the humidistat feature enable, not the on/off mode control signal.
The BaseEvent event will trigger with HumidifierEnableFeedbackEventId for this property. (Inherited from DinThstat) | |
| HumidistatMode |
Sets the Humidistat mode.
(Inherited from DinThstat) | |
| HumidistatModeFeedback |
Reports the current Humidistat mode.
The BaseEvent event will trigger with HumidifierModeFeedbackEventId for this property. (Inherited from DinThstat) | |
| HumidityCallFeedbacks |
Returns a collection of components that indicate when the system is making a humidity call.
The ClimateControlComponentCallChange event will trigger with ClimateControlComponent object. (Inherited from DinThstat) | |
| HumiditySetpoint |
Reports the current Humidistat setpoint value in 1% RH ticks.
Use PercentToUshort(Single) to convert
the percentage to a ushort value or UshortToPercent(UInt16) to convert
the ushort value to percentage.
(Inherited from DinThstat) | |
| HumiditySetpointFeedback |
Reports the current Humidistat setpoint value in 1% RH ticks.
Use PercentToUshort(Single) to convert
the percentage to a ushort value or UshortToPercent(UInt16) to convert
the ushort value to percentage.
The BaseEvent event will trigger with HumiditySetpointFeedbackEventId. (Inherited from DinThstat) | |
| ID |
Property to get the ID of the device.
(Inherited from GenericDevice) | |
| IndoorHumidity |
Property to provide indoor humidity in 1%RH ticks. For UI display only.
This property is not supported by "HzThstat" device class and returns NullUShortInputSig when read.
Use PercentToUshort(Single) to convert
the percentage to a ushort value or UshortToPercent(UInt16) to convert
the ushort value to percentage.
(Inherited from DinThstat) | |
| InvalidFcuChangeoverTemperatureFeedback |
Property to indicate when a 2-pipe fan coil unit system does not have an auto changeover (pipe) temperature sensor available.
This will be high either when no sensor is defined as such, or when its data is not valid.
True: The 2-pipe fan coil unit does not have a valid auto changeover sensor, False : The 2-pipe fan coil unit does have a valid auto changeover sensor.
The BaseEvent event will trigger with InvalidFcuChangeoverTemperatureEventId object. | |
| InvalidFloorTemperatureFeedback |
Property to report if the device does not have a valid sensor source for floor temperature regulation/max temperature limiting.
true = no valid sensor present; false = valid sensor present
The BaseEvent event will trigger with InvalidFloorTemperatureFeedbackEventId object. (Inherited from DinThstat) | |
| InvalidOutdoorTemperatureFeedback |
Property to report when device requires outdoor temperature and no valid source is present.
Outdoor temperature is required in heat pump systems for proper balance point operation.
Device may operate sub-optimally with timing-based safeguards to ensure freeze out protection.
Note for balance point operation, outdoor temperature may be sourced from control system via OutdoorTemperatureInput.
true = no valid sensor present; false = valid sensor present
The BaseEvent event will trigger with InvalidOutdoorTemperatureFeedbackEventId object. (Inherited from DinThstat) | |
| InvalidRegulationHumidityFeedback |
Indicates if device does not have a valid sensor source for space humidity regulation.
true = valid sensor not present; false = valid sensor present
The BaseEvent event will trigger with RegHumInvalidEventId. (Inherited from DinThstat) | |
| InvalidRegulationTemperatureFeedback |
Indicates that if device does not have a valid sensor source for space (air) temperature regulation.
true = no valid sensor present; false = valid sensor present
The BaseEvent event will trigger with InvalidRegulationTemperatureFeedbackEventId object. (Inherited from DinThstat) | |
| IsOnline |
Property to get the current online state of the device.
(Inherited from GenericDevice) | |
| LocalHumidityFeedback |
Property to indicate local humidity on the device.
The HumidityEvent event will trigger with eHumidityType and LocalHumidityFeedback value. | |
| LocalTemperatureFeedback |
Reports the local temperature reported by the Local sensor.
Only enabled when EnableSensorOutputs is enabled.
This property is supported by "HZThstat" not supported by "DinThstat".
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| MaximumAuto1ptSetpointFeedback |
Property to report maximum auto setpoint (single-SP format) in 10ths of current unit.
The BaseEvent event will trigger with MaximumAuto1ptSetpointFeedbackEventId for this property. (Inherited from DinThstat) | |
| MaximumCoolSetpointFeedback |
Property to report maximum cool setpoint in 10ths of the current unit.
The BaseEvent event will trigger with MaximumCoolSetpointFeedbackEventId for this property. (Inherited from DinThstat) | |
| MaximumFloorWarmingSetpointFeedback |
Property to report maximum floor warming setpoint in 10ths of the current unit.
The BaseEvent event will trigger with MaximumFloorWarmingSetpointFeedbackEventId for this property. (Inherited from DinThstat) | |
| MaximumHeatSetpointFeedback |
Property to report maximum heat setpoint in 10ths of the current unit (required for scheduler).
The BaseEvent event will trigger with MaximumHeatSetpointFeedbackEventId for this property. (Inherited from DinThstat) | |
| MaximumHumiditySetpointFeedback |
Reports the maximum humidistat setpoint in 1% RH ticks.
Use PercentToUshort(Single) to convert
the percentage to a ushort value or UshortToPercent(UInt16) to convert
the ushort value to percentage.
The BaseEvent event will trigger with MaximumHumiditySetpointFeedbackEventId. (Inherited from DinThstat) | |
| MinimumAuto1ptSetpointFeedback |
Property to report minimum auto setpoint (single-SP format) in 10ths of current unit.
The BaseEvent event will trigger with MinimumAuto1ptSetpointFeedbackEventId for this property. (Inherited from DinThstat) | |
| MinimumCoolSetpointFeedback |
Property to report minimum cool setpoint in 10ths of the current unit.
The BaseEvent event will trigger with MinimumCoolSetpointFeedbackEventId for this property. (Inherited from DinThstat) | |
| MinimumFloorWarmingSetpointFeedback |
Property to report minimum floor warming setpoint in 10ths of the current unit.
The BaseEvent event will trigger with MinimumFloorWarmingSetpointFeedbackEventId for this property. (Inherited from DinThstat) | |
| MinimumHeatSetpointFeedback |
Property to report minimum heat setpoint in 10ths of the current unit (required for scheduler).
The BaseEvent event will trigger with MinimumHeatSetpointFeedbackEventId for this property. (Inherited from DinThstat) | |
| MinimumHumiditySetpointFeedback |
Reports the minimum humidistat setpoint in 1% RH ticks.
Use PercentToUshort(Single) to convert
the percentage to a ushort value or UshortToPercent(UInt16) to convert
the ushort value to percentage.
The BaseEvent event will trigger with MinimumHumiditySetpointFeedbackEventId. (Inherited from DinThstat) | |
| Name |
Get the name of this device.
(Inherited from GenericBase) | |
| NumberOfRelayPorts |
Number of relay ports this device supports on Current System State slot.
HZ-THSTAT does not support this property and returns '0' when used.
(Inherited from DinThstat) | |
| OutdoorHumidity |
Property to provide outdoor humidity in 1%RH ticks. For displaying OD conditions on UI.
Use PercentToUshort(Single) to convert
the percentage to a ushort value or UshortToPercent(UInt16) to convert
the ushort value to percentage.
(Inherited from DinThstat) | |
| OutdoorHumidityFeedback |
Property to report the outdoor humidity in 1%RH ticks. For displaying OD conditions on UI.
Use PercentToUshort(Single) to convert
the percentage to a ushort value or UshortToPercent(UInt16) to convert
the ushort value to percentage.
The HumidityEvent event will trigger with eHumidityType and OutdoorHumidityFeedback value. (Inherited from DinThstat) | |
| OutdoorTemperatureFeedback |
Sends the current outdoor temperature to the thermostat.
This input should only be used for heatpump/dual fuel balance point systems, not heat/cool system types.
The value should be sent in tenths of a degree (1d = 0.1 degrees) based on the current temperature scale (Fahrenheit or Celsius).
For example, if the outdoor temperature is 45.3°F, the value should be 453.
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| OutdoorTemperatureInput |
Sends the current outdoor temperature to the thermostat.
This input should only be used for heatpump/dual fuel balance point systems, not heat/cool system types.
The value should be sent in tenths of a degree (1d = 0.1 degrees) based on the current temperature scale (Fahrenheit or Celsius).
For example, if the outdoor temperature is 45.3°F, the value should be 453d.
(Inherited from Thermostat) | |
| Parent |
The parent that a given object was added to.
(Inherited from GenericBase) | |
| RawRelayCallMaskFeedback |
Reports a mask of the actual relays being called. For debug only.
Normal end user UI operation would not want to use this signal.
The BaseEvent event will trigger with RawRelayCallMaskFeedbackEventId. (Inherited from DinThstat) | |
| Registerable |
Property to indicate that this device can be registered.
(Inherited from GenericDevice) | |
| Registered |
Property to get the current registration state of the device.
(Inherited from GenericDevice) | |
| RegistrationFailureReason |
Property to get the Registration Failure Reason, this will match the return value from the call to register.
(Inherited from GenericDevice) | |
| RegulationHumidityFeedback |
Reports the current value of the humidistat regulation humidity (as would be displayed on the thermostat UI, which can be an average of multiple sensors).
The HumidityEvent event will trigger with eHumidityType and RegulationHumidityFeedback value. (Inherited from DinThstat) | |
| RegulationTemperatureFeedback |
Reports displayed temperature, which can be the Local temperature or the Remote 1 temperature, or the average of Local and Remote 1,
based on the option selected in the Setup menu (Local = i; Remote 1 = r; Average = ir).
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| RelayPorts |
Collection of relay ports on the device on Current System State slot.
HZ-THSTAT does not support this property and returns an empty collection when used.
(Inherited from DinThstat) | |
| Remote1HumidityFeedback | Reports the humidity reading of the Remote 1 humidity sensor in whole numbers. The Remote 1 humidity reading is reported regardless of the Use/Omit/OD designation. The HumidityEvent event will trigger with eHumidityType and Remote1HumidityFeedback value. (Inherited from DinThstat) | |
| Remote1TemperatureFeedback |
Reports the temperature reported by the Remote 1 sensor.
Only enabled when EnableSensorOutputs is enabled.
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| Remote2HumidityFeedback |
Reports the humidity reading of the Remote 2 humidity sensor in whole numbers.
The Remote 2 humidity reading is reported regardless of the Use/Omit/OD designation.
The HumidityEvent event will trigger with eHumidityType and Remote2HumidityFeedback value. (Inherited from DinThstat) | |
| Remote2TemperatureFeedback |
Reports the local temperature reported by the Remote 2 sensor.
Only enabled when EnableSensorOutputs is enabled.
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from Thermostat) | |
| Remote3HumidityFeedback |
Reports the humidity reading of the Remote 3 humidity sensor in whole numbers.
The Remote 3 humidity reading is reported regardless of the Use/Omit/OD designation.
This property is not supported for HZ-THSTAT.
The HumidityEvent event will trigger with eHumidityType and Remote3HumidityFeedback value. (Inherited from DinThstat) | |
| Remote3TemperatureFeedback |
Reports the temperature from the remote sensor channel3 in tenths of the current unit, regardless of how sensor is configured.
This property is not supported by HZ-THSTAT.
The TemperatureChange event will trigger with temperatureType and newTemperature. (Inherited from DinThstat) | |
| SchedulerEnabledFeedback |
Property to indicate if Scheduler operation is available. Some installations may not require scheduler operation (not related to run/hold state).
The BaseEvent event will trigger with SchedulerEnabledFeedbackEventId for this property. (Inherited from DinThstat) | |
| SchedulerOperation |
Scheduler Operation present on this device. This property will be 'null' when not supported.
This Property is not supported by HZ-THSTAT.
This property will trigger BaseEvent with event IDs defined in DinThstat. (Inherited from DinThstat) | |
| SchedulerRunHold |
Property to set the run/hold state of the scheduler.
(Inherited from DinThstat) | |
| SchedulerRunHoldFeedback |
Property to report the run/hold state of the scheduler.
The BaseEvent event will trigger with SchedulerRunHoldFeedbackEventId. (Inherited from DinThstat) | |
| SIMPLDeviceImplementation |
Internal protected member used for actual device control.
(Inherited from GenericDevice) | |
| SpaceAutoEnabledFeedback |
Property to indicate if the space auto system mode is available. Unsupported modes can be disabled in setup to reduce UI clutter.
The BaseEvent event will trigger with SpaceAutoEnabledFeedbackEventId for this property. (Inherited from DinThstat) | |
| SpaceAuxHeatEnabledFeedback |
Property to indicate if aux-heat-only mode is available. Duplicates AnySpaceSystemTypeFeedback state. For clarity, may want to keep a dedicated signal.
The BaseEvent event will trigger with SpaceAuxHeatEnabledFeedbackEventId for this property. (Inherited from DinThstat) | |
| SpaceCoolEnabledFeedback |
Property to indicate if the space cool system mode is available. Unsupported modes can be disabled in setup to reduce UI clutter.
The BaseEvent event will trigger with SpaceCoolEnabledFeedbackEventId. (Inherited from DinThstat) | |
| SpaceHeatEnabledFeedback |
Property to indicate if the space heat system mode is available. Unsupported modes can be disabled in setup to reduce UI clutter.
The BaseEvent event will trigger with SpaceHeatEnabledFeedbackEventId. (Inherited from DinThstat) | |
| SpaceSystemMode |
Sets the space system mode.
(Inherited from DinThstat) | |
| SpaceSystemModeFeedback |
Reports the commanded/current space system mode.
The BaseEvent event will trigger with SpaceSystemModeFeedbackEventId. (Inherited from DinThstat) | |
| Type |
Property to determine to type of device this is.
(Inherited from GenericDevice) | |
| UiLanguage |
Property to set the HZ-THSTAT User Interface Language.
Property not supported by DIN-TSTAT, returns '0' when used.
Property not supported by HZ-TSTAT in the 1.000.XXXX firmware release. Reserved for future use.
(Inherited from DinThstat) | |
| UiLanguageFeedback |
Property to report the current HZ-THSTAT User Interface Language.
Property not supported by DIN-TSTAT, returns '0' when used.
Property not supported by HZ-TSTAT in the 1.000.XXXX firmware release. Reserved for future use.
The BaseEvent event will trigger with UiLanguageFeedbackEventId. (Inherited from DinThstat) | |
| UnRegistrationFailureReason |
Property to get the Unregistration Failure Reason, this will match the return value from the call to unregister.
(Inherited from GenericDevice) | |
| UserSpecifiedObject |
Can be assigned anything that user wants.
(Inherited from GenericBase) | |
| XioEndpointStubSIMPLDevice |
The SIMPL "stub" Device that the XiO Director creates for an endpoint to send the 1C/0E to the
correct place in hierarchy.
(Inherited from GenericDevice) | |
| ZoneName |
Property for naming device zone/use.
(Inherited from DinThstat) | |
| ZoneNameFeedback |
Property to return the name of the device zone/use.
The BaseEvent event will trigger with ZoneNameFeedbackEventId. (Inherited from DinThstat) |