Crestron. |
| Class | Description | |
|---|---|---|
| ZumDaliController | Zum Dali controller class. | |
| ZumDaliDriverReplacement | Zum Dali Driver Replacement class. | |
| ZumEnergyMonitor |
This is Energy Monitor Class for Zum Wired JBox devices.
This class is not supported by ZUMLINK-JBOX-IO and ZUMLINK-DIN-IO.
This class will trigger EnergyMonitorChange event. | |
| ZumJBoxDaliDriver | DALI Driver class for ZUMLINK JBOX DALI (GROUPS) Device. | |
| ZumJBoxEventIds | Event Id Class for ZUM JBOX Devices | |
| ZumJBoxPlugLoad | ZUM Wired Plug load class. | |
| ZumJBoxPlugLoadBase | ZUM Wired Plug load base class. | |
| ZumJBoxSwitchLoad | ZUM Wired Switch load class. | |
| ZumJBoxSwitchLoadBase |
This is base class for ZumJBoxPlugLoad and ZumJBoxSwitchLoad.
This class will trigger BaseEvent, OverrideEventHandler events, whenever there is a External or Manual override feedback. | |
| ZumLinkDin16ALv |
ZUM Wired 0-10V Dimming load controller with one load on Cresnet with Photo and Occupancy Sensors and Energy Monitor.
This class will trigger LoadStateChange, OverrideEventHandler, OccupancySensorChange, PhotoSensorChange and EnergyMonitorChange events. | |
| ZumLinkDin20APlug |
ZUM Wired Plug load controller with one load on Cresnet with Photo and Occupancy Sensors and Energy Monitor.
This class will trigger LoadStateChange, OverrideEventHandler, OccupancySensorChange, PhotoSensorChange and EnergyMonitorChange events. | |
| ZumLinkDin20ASw |
ZUM Wired Switching load controller with one load on Cresnet with Photo and Occupancy Sensors and Energy Monitor.
This class will trigger LoadStateChange, OverrideEventHandler, OccupancySensorChange, PhotoSensorChange and EnergyMonitorChange events. | |
| ZumLinkDinDimu |
ZUM Wired 0-10V Dimming load controller with one load on Cresnet with Photo and Occupancy Sensors and Energy Monitor.
This class will trigger LoadStateChange, OverrideEventHandler, OccupancySensorChange, PhotoSensorChange and EnergyMonitorChange events. | |
| ZumLinkDinIo |
ZUM Wired input output with two relays and no Photo and Occupancy sensor and Energy Monitor support on Cresnet.
This class will trigger LoadStateChange and OverrideEventHandler events. | |
| ZumLinkDtQuattroDls |
ZUM Wired Occupancy or Vacancy (Steinel) Sensor on Cresnet.
This class will trigger OccupancySensorChange and PhotoSensorChange events. | |
| ZumLinkDtQuattroDlsRly |
ZUM Wired Occupancy or Vacancy (Steinel) Sensor with Relay on Cresnet.
This class will trigger OccupancySensorChange, PhotoSensorChange and LoadStateChange events. | |
| ZumLinkExp16ADimu |
ZUM Wired 0-10V Dimming load controller with one load and no Photo and Occupancy sensor and Energy Monitor support on Cresnet.
This class will trigger LoadStateChange and OverrideEventHandler events. | |
| ZumLinkIoBase |
Base class for ZumLinkJBoxIo and ZumLinkDinIo.
This class will trigger LoadStateChange and ZumLinkJBoxIoLedChange events. | |
| ZumLinkIrQuattroDls |
ZUM Wired Occupancy or Vacancy (Steinel) Sensor on Cresnet.
This class will trigger OccupancySensorChange and PhotoSensorChange events. | |
| ZumLinkIrQuattroDlsRly |
ZUM Wired Occupancy or Vacancy (Steinel) Sensor with Relay on Cresnet.
This class will trigger OccupancySensorChange, PhotoSensorChange and LoadStateChange events. | |
| ZumLinkIrQuattroHdDls |
ZUM Wired Occupancy or Vacancy (Steinel) Sensor on Cresnet.
This class will trigger OccupancySensorChange and PhotoSensorChange events. | |
| ZumLinkIrQuattroHdDlsRly |
ZUM Wired Occupancy or Vacancy (Steinel) Sensor with Relay on Cresnet.
This class will trigger OccupancySensorChange, PhotoSensorChange and LoadStateChange events. | |
| ZumLinkJBox16ALv |
ZUM Wired 0-10V Dimming load controller with one load on Cresnet with Photo and Occupancy Sensors and Energy Monitor.
This class will trigger LoadStateChange, OverrideEventHandler, OccupancySensorChange, PhotoSensorChange and EnergyMonitorChange events. | |
| ZumLinkJbox20APlug |
ZUM Wired Plug load controller with one load on Cresnet with Photo and Occupancy Sensors and Energy Monitor.
This class will trigger LoadStateChange, OverrideEventHandler, OccupancySensorChange, PhotoSensorChange and EnergyMonitorChange events. | |
| ZumLinkJbox20ASw |
ZUM Wired Switching load controller with one load on Cresnet with Photo and Occupancy Sensors and Energy Monitor.
This class will trigger LoadStateChange, OverrideEventHandler, OccupancySensorChange, PhotoSensorChange and EnergyMonitorChange events. | |
| ZumLinkJBoxIo |
ZUM Wired input output with two relays on Cresnet.
This class will trigger LoadStateChange and OverrideEventHandler events. | |
| ZumLinkJBoxIoInputConfig | ZUMLINK-JBOX-IO and ZUMLINK-DIN-IO input config class. | |
| ZumLinkJBoxIoInputs | ZUMLINK-JBOX-IO and ZUMLINK-DIN-IO Inputs class. | |
| ZumLinkJBoxIoLed | Class for ZumLinkJBoxIO LED class. This class triggers ZumLinkJBoxIoLedChange event. | |
| ZumLinkOccupancySensor |
This is Occupancy Sensor class for Zum Link Occupancy Vacancy Sensor devices.
This class will trigger OccupancySensorChange event. | |
| ZumLinkOccupancyVacancySensorBase | This is base class for ZumLinkDtQuattroDls, ZumLinkIrQuattroDls, ZumLinkIrQuattroHdDls, ZumLinkUsHallwayDls, ZumLinkUsOnewayDls and ZumLinkUsQuattroDls. | |
| ZumLinkOccupancyVacancySensorWithRelayBase | This is base class for ZumLinkDtQuattroDlsRly, ZumLinkIrQuattroDlsRly, ZumLinkIrQuattroHdDlsRly, ZumLinkUsHallwayDlsRly, ZumLinkUsOnewayDlsRly and ZumLinkUsQuattroDlsRly. | |
| ZumLinkRelay |
Relay class for ZUM Occupancy and Vacancy Sensor Devices.
This class will trigger BaseEvent and OverrideEventHandler events. | |
| ZumLinkUsHallwayDls |
ZUM Wired Occupancy or Vacancy (Steinel) Sensor on Cresnet.
This class will trigger OccupancySensorChange and PhotoSensorChange events. | |
| ZumLinkUsHallwayDlsRly |
ZUM Wired Occupancy or Vacancy (Steinel) Sensor with Relay on Cresnet.
This class will trigger OccupancySensorChange, PhotoSensorChange and LoadStateChange events. | |
| ZumLinkUsOnewayDls |
ZUM Wired Occupancy or Vacancy (Steinel) Sensor on Cresnet.
This class will trigger OccupancySensorChange and PhotoSensorChange events. | |
| ZumLinkUsOnewayDlsRly |
ZUM Wired Occupancy or Vacancy (Steinel) Sensor with Relay on Cresnet.
This class will trigger OccupancySensorChange, PhotoSensorChange and LoadStateChange events. | |
| ZumLinkUsQuattroDls |
ZUM Wired Occupancy or Vacancy (Steinel) Sensor on Cresnet.
This class will trigger OccupancySensorChange and PhotoSensorChange events. | |
| ZumLinkUsQuattroDlsRly |
ZUM Wired Occupancy or Vacancy (Steinel) Sensor with Relay on Cresnet.
This class will trigger OccupancySensorChange, PhotoSensorChange and LoadStateChange events. | |
| ZumNetBridge |
Ethernet/Cresnet bridge that allows control system access to the components on the local cresnet bus within the room. Controls/coordinates room level
operations amongst devices on the room’s cresnet bus operates as a single client on the room’s cresnet bus cresnet bus master operation required for room controller operation presents the Room as a device to the Ethernet network appears as a device on the room’s cresnet network allows operation as an Ethernet/Cresnet Bridge to the devices on the room’s cresnet network this feature can be enabled/disabled from the control system cresnet bus master operation required for Bridge operation, already present for Room Control. | |
| ZumNetBridgeBase | Base class for ZumNetBridge and ZumNetBridgeRoom device classes. | |
| ZumNetBridgeRoom |
Ethernet/Cresnet bridge that allows control system access to the components on the local cresnet bus within the room and also allows the control system
to address the room as a whole through additional joins. Controls/coordinates room level operations amongst devices on the room’s cresnet bus operates as a single client on the room’s cresnet bus. Cresnet bus master operation required for room controller operation presents the Room as a device to the Ethernet network appears as a device on the room’s cresnet network allows operation as an Ethernet/Cresnet Bridge to the devices on the room’s cresnet network this feature can be enabled/disabled from the control system cresnet bus master operation required for Bridge operation, already present for Room Control. | |
| ZumNetBridgeRoomZumWiredRoomInterface | This is Room Interface Class for ZumNet Bridge devices. | |
| ZumNetBridgeRoomZumWiredRoomInterfaceDevice |
Device class that has the info of a device on the JBOX unit. e.g. ZUMNET-JBOX-16A-LV have Dimming Load controller, Occupancy Sensor,
Photo Sensor and Energy Monitor devices on it. | |
| ZumNetBridgeRoomZumWiredRoomInterfaceJBoxUnitInfo | JBOX Unit Info class that has the details about the ZUM Wired JBOX Units and the Devices on the Units. | |
| ZumNetBridgeRoomZumWiredRoomInterfaceUnit | ZUM Wired JBOX Unit class, e.g. ZUMNET-JBOX-16A-LV. | |
| ZumNetBridgeRoomEventIds | Event Id Class for ZUMNET BRIDGE ROOM Device. | |
| ZumNetDin16ALv |
ZUM Wired 0-10V Dimming load controller with one load on Cresnet and also has ethernet interface to act like ZUMNET-BRIDGE or ZOOM-NET-BRIDGE-ROOM,
with Photo and Occupancy Sensors and Energy Monitor. This class will trigger LoadStateChange, OverrideEventHandler, OccupancySensorChange, PhotoSensorChange and EnergyMonitorChange events. | |
| ZumNetDinDliGroups |
This is ZUMNET-DIN-DLI(GROUPS) device class.
This class will trigger ZumDaliControllerChange ,EnergyMonitorChange, DaliDriverChange,ZumDaliDriverReplacementChange, OverrideEventHandler, OccupancySensorChange and PhotoSensorChangeevent. | |
| ZumNetJBox16ALv |
ZUM Wired 0-10V Dimming load controller with one load on Cresnet and also has ethernet interface to act like ZUMNET-BRIDGE or ZOOM-NET-BRIDGE-ROOM,
with Photo and Occupancy Sensors and Energy Monitor. This class will trigger LoadStateChange, OverrideEventHandler, OccupancySensorChange, PhotoSensorChange and EnergyMonitorChange events. | |
| ZumNetJBoxDali |
ZUM Wired DALI load controller with 17 loads/groups including Dali Global group on Cresnet and also has ethernet interface to act like
ZUMNET-BRIDGE or ZOOM-NET-BRIDGE-ROOM. This class will trigger BaseEvent, OverrideEventHandler, OccupancySensorChange and PhotoSensorChange events. | |
| ZumNetJBoxDaliGroups |
This is ZUMNET-JBOX-DALI(Groups) device class.
This class will trigger ZumDaliControllerChange ,EnergyMonitorChange, DaliDriverChange,ZumDaliDriverReplacementChange,OverrideEventHandler, OccupancySensorChange and PhotoSensorChangeevent. | |
| ZumNetJBoxDaliGroupsEventIds | Event id class for ZUMNET-JBOX-DALI(Groups) device. | |
| ZumNetJBoxDaliLegacy |
ZUMNET-JBOX-DALI-LEGACY class
This class will trigger BaseEvent, OccupancySensorChange, PhotoSensorChange and EnergyMonitorChange events. | |
| ZumNetJBoxDinDaliCustomBase |
Base class for ZUMNET-JBOX-DALI-LEGACY devices.
This class will trigger BaseEvent, OccupancySensorChange, PhotoSensorChange and EnergyMonitorChange events. | |
| ZumNetJBoxDinDaliGroupsBase |
This is base class for ZUMNET-JBOX-DALI(Groups) and ZUMNET-DIN-DLI(Groups) device classes.
This class will trigger ZumDaliControllerChange ,EnergyMonitorChange, DaliDriverChange,ZumDaliDriverReplacementChange,OverrideEventHandler, OccupancySensorChange and PhotoSensorChangeevent. | |
| ZumOccupancySensor |
This is Occupancy Sensor class for Zum Wired JBox devices.
This class will trigger OccupancySensorChange event. | |
| ZumPhotoSensor |
This is Photo Sensor Class for Zum Wired JBox devices.
This class will trigger PhotoSensorChange event. | |
| ZumXJBoxDimmer | This is base class for ZumLinkJBox16ALv, ZumNetJBox16ALv, "ZumLinkJBox16ALvE" ,"ZumLinkJBoxDali" and "ZumLinkExp16ADimu". | |
| ZumXJBoxDimmer16ALv | This is base class for ZumLinkJBox16ALv and ZumNetJBox16ALv. | |
| ZumXJBoxDimmerWithPhotoAndOccupancySensors | This is base class for ZumLinkJBox16ALv, ZumNetJBox16ALv and "ZumLinkJBoxDali". | |
| ZumXJBoxPlug | This is Base class for ZumLinkJbox20APlug. | |
| ZumXJBoxSwitch | This is base class for ZumLinkJbox20ASw. | |
| ZumXJBoxSwitchBase | This is base class for ZumXJBoxPlug and ZumXJBoxSwitch. |
| Enumeration | Description | |
|---|---|---|
| eLedBlinkPattern | Enum to define the blink patterns. | |
| ZumDaliControllereAddressingOperation | Enum to define the addressing Operation modes. | |
| ZumDaliControllereDaliMode | Enum to define the dali mode. | |
| ZumDaliControllereDesiredGroupType | Enum to define the desired group types. | |
| ZumDaliControllereDiagnosticStageOneStatusFlag | Enum to define the diagnostic stage one status flags. Flags BusVoltageErrorand UnaddressedDriver means either one of these two flags will be set at any point of time. | |
| ZumJBoxDaliDrivereDaliDriverDiagnosticFlag | Enum to define the diagnostic Flags of the driver. Flags Missing, CommunicationError and DuplicateDriverFound are mutually exclusive, means either one of these three flags will be set at any point of time. | |
| ZumNetBridgeRoomZumWiredRoomInterfaceeBluetoothPinAcceptanceValues | Enum for bluetooth pin acceptance values. | |
| ZumNetBridgeRoomZumWiredRoomInterfaceeBluetoothPinAlert | Enum for bluetooth pin alerts. | |
| ZumNetBridgeRoomZumWiredRoomInterfaceeBluetoothPinType | Enum for Bluetooth pin types. | |
| ZumNetJBoxDinDaliCustomBaseeDaliOperatingMode | Enum to define the device operating modes |