Click or drag to resize

ZumEnergyMonitor Class

This is Energy Monitor Class for Zum Wired JBox devices. This class is not supported by ZUMLINK-JBOX-IO and ZUMLINK-DIN-IO.

This class will trigger EnergyMonitorChange event.

Inheritance Hierarchy
SystemObject
  Crestron.SimplSharpPro.Lighting.ZumWiredZumEnergyMonitor

Namespace: Crestron.SimplSharpPro.Lighting.ZumWired
Assembly: Crestron.SimplSharpPro.Lighting (in Crestron.SimplSharpPro.Lighting.dll) Version: 2.21.121
Syntax
C#
public sealed class ZumEnergyMonitor : IParentInformation

The ZumEnergyMonitor type exposes the following members.

Properties
 NameDescription
Public propertyAccumulatedEnergyAndTimeReportedFeedback Property to indicate if the AccumulatedEnergyKwhFeedback and AccumulatedTimeMinutesFeedback have been refreshed and are ready to process.

true: accumulated energy and time are refreshed; false: accumulated energy and time are not refreshed

This property will trigger EnergyMonitorChange event with AccumulatedEnergyAndTimeReportedEventId.

This property is not supported by ZUMLINK-JBOX-IO and ZUMLINK-DIN-IO.
Public propertyAccumulatedEnergyKwhFeedback Property to report the accumulated energy in Kilo Watt Hours (KWh).

This property will trigger EnergyMonitorChange event with AccumulatedEnergyKwhFeedbackEventId.

This property is not supported by ZUMLINK-JBOX-IO and ZUMLINK-DIN-IO.
Public propertyAccumulatedTimeMinutesFeedback Property to report the accumulated time in minutes.

This property will trigger EnergyMonitorChange event with AccumulatedTimeMinutesFeedbackEventId.

This property is not supported by ZUMLINK-JBOX-IO and ZUMLINK-DIN-IO.
Public propertyEnablePowerReport This property is to enable the power reporting on the device.

true: enable power reporting on the device; false: disable power reporting on the device

This property is not supported by ZUMLINK-JBOX-IO and ZUMLINK-DIN-IO.
Public propertyParent The parent that a ZumEnergyMonitor object was added to.
Public propertyPowerReportEnabledFeedback Property to indicate that the power reporting is enabled on the device.

true: power reporting enabled; false: power reporting disabled

This property will trigger EnergyMonitorChange event with PowerReportEnabledEventId.

This property is not supported by ZUMLINK-JBOX-IO and ZUMLINK-DIN-IO.
Public propertyPowerUsageWattsFeedback Property to report the power usage in watts.

This property will trigger EnergyMonitorChange event with PowerUsageWattsFeedbackEventId.

This property is not supported by ZUMLINK-JBOX-IO and ZUMLINK-DIN-IO.
Public propertyUserSpecifiedObject Can be assigned anything that user wants.
Top
Methods
 NameDescription
Public methodEqualsDetermines whether the specified object is equal to the current object.
(Inherited from Object)
Public methodGetAccumulatedEnergyAndTime Method to get the accumulated energy and time. This property is not supported by ZUMLINK-JBOX-IO and ZUMLINK-DIN-IO.
Public methodGetHashCodeServes as the default hash function.
(Inherited from Object)
Public methodGetTypeGets the Type of the current instance.
(Inherited from Object)
Public methodResetAccumulatedEnergyAndTime Method to reset the accumulated energy and time. This property is not supported by ZUMLINK-JBOX-IO and ZUMLINK-DIN-IO.
Public methodToStringReturns a string that represents the current object.
(Inherited from Object)
Top
Events
 NameDescription
Public eventEnergyMonitorChange Event triggered when a feedback has changed for this ZumEnergyMonitor.
Top

Version Information

.NET

Supported in: 6.0

.NET Compact Framework

Supported in: 3.5
See Also