HumidityThermostat Properties

The HumidityThermostat type exposes the following members.

Properties
 NameDescription
Public propertyDehumidityCallFeedbacks Returns a collection of components that indicate when the system is making a dehumidity call.
Public propertyDispHumidityModePage Indicates that the Humidity Mode page has been enabled for display on the thermostat LCD. The output remains true for as long as the page is enabled. The Humidity Mode page allows the user to enable or disable the humidifier.
Public propertyDispHumidityViewPage Indicates that the Humidity View page has been enabled for display on the thermostat LCD. The output remains true for as long as the page is enabled. The Humidity View Page displays the relative humidity and setpoint values.
Public propertyHumidifierEnable Enables the humidifier.
Public propertyHumidifierEnableFeedback Indicates that the humidifier is enabled.
Public propertyHumidifierMode Sets the Humidifier mode.
Public propertyHumidifierModeFeedback Reports the current Humidifier mode.
Public propertyHumidifierOff Turns off the humidifier.
Public propertyHumidifierOffFeedback Indicates that the humidifier is off.
Public propertyHumidityCallFeedbacks Returns a collection of components that indicate when the system is making a humidity call.
Public propertyHumiditySetpoint Sets the humidity regulating setpoint in whole numbers. Valid values range from 5 to 90. Out of range values are ignored.
Public propertyHumiditySetpointFeedback Reports the humidity regulating setpoint.
Public propertyHumiditySetpointMinus Lowers the humidity regulating setpoint. Continuing to assert the up or down inputs at the limits of the setpoint will not affect the setpoint. That is, the setpoint will hold at its maximum or minimum setting.
Public propertyHumiditySetpointPlus Raises the humidity regulating setpoint. Continuing to assert the up or down inputs at the limits of the setpoint will not affect the setpoint. That is, the setpoint will hold at its maximum or minimum setting.
Public propertyIndoorHumidityInput Receives the indoor relative humidity from a sensor that is not connected to the thermostat, for display on the Main page of the thermostat LCD (CHV-TSTAT only). This value is ignored if a humidity sensor (CHV-RTHS) is connected to the CHV-TSTAT. This property is not supported by HZ-THSTAT.
Public propertyLocalHumidity Reports the relative humidity reading of the built-in humidity sensor (CHV-THSTAT only) in whole numbers. The internal humidity sensor reading is reported regardless of the Use or Omit designation.
Public propertyLocalHumInvalid Indicates that the corresponding when remote humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent.
Public propertyMainScrnObHumidity Reports if indoor humidity will be the reading that will be displayed under the current temperature on the Main page of the thermostat LCD.
Public propertyMaximumHumiditySetpointFeedback Reports the humidity regulating setpoint.
Public propertyMinimumHumiditySetpointFeedback Reports the humidity regulating setpoint.
Public propertyODHumInvalid Indicates that the corresponding when remote humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent.
Public propertyODRem1Humidity Reports if ODRem1Humidity will be the designator assigned to the remote sensors.
Public propertyODRem2Humidity Reports if ODRem2Humidity will be the designator assigned to the remote sensors.
Public propertyOmitLocalHumidity Reports if local humidity will not be the designator assigned to the local (internal) sensors.
Public propertyOmitRem1Humidity Reports if Rem1Humidity will not be the designator assigned to the remote sensors.
Public propertyOmitRem2Humidity Reports if OmitRem2Humidity will not be the designator assigned to the remote sensors.
Public propertyOutdoorHumidity Reports the humidity reading of any humidity sensor set to "OD" (Outdoor) in whole numbers. If more than one humidity sensor is set to OD, this is the mean outdoor humidity. Humidity sensors are manually set to Use, Omit, or Outdoor via the setup menus on the thermostat.
Public propertyOutdoorHumidityInput Receives the outdoor relative humidity from a sensor that is not connected to the thermostat, for display on the Outdoor page of the thermostat LCD. This value is ignored if an outdoor humidity sensor (CHV-RTHS) is connected to the thermostat.
Public propertyRegHumInvalid Indicates that the corresponding when remote humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent.
Public propertyRegulationHumidity Reports the mean (averaged) humidity reading of all internal and remote humidity sensors set to "Use", in whole numbers. Humidity sensors are manually set to Use, Omit, or Outdoor via the setup menus on the thermostat.
Public propertyRem1HumInvalid Indicates that the corresponding when remote humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent.
Public propertyRem2HumInvalid Indicates that the corresponding when remote humidity sensor isn't reporting valid data. The output remains true for as long as the sensor source doesn't have valid data. This can indicate a problem with the sensor, or the sensor being absent.
Public propertyRemote1Humidity Reports the humidity reading of the Remote 1 humidity sensor in whole numbers. The Remote 1 humidity reading is reported regardless of the Use/Omit/OD designation.
Public propertyRemote2Humidity Reports the humidity reading of the Remote 2 humidity sensor in whole numbers. The Remote 2 humidity reading is reported regardless of the Use/Omit/OD designation.
Public propertyRemote3Humidity Reports the humidity reading of the Remote 3 humidity sensor in whole numbers. The Remote 3 humidity reading is reported regardless of the Use/Omit/OD designation.
Public propertyUseLocalHumidity Reports if local humidity will be the designator assigned to the local (internal) sensors.
Public propertyUseRem1Humidity Reports if Rem1Humidity will be the designator assigned to the remote sensors.
Public propertyUseRem2Humidity Reports if UseRem2Humidity will be the designator assigned to the remote sensors.