ClciMcexMotorController Properties

The ClciMcexClciMcexMotorController type exposes the following members.

Properties
 NameDescription
Public propertyCloseMomentaryFull Closes the shade group toward the full closed position for as long as the value is true (close momentary) and stops on release. If the property changes from true to false within 0.5 seconds, then the shades close to the full closed position (close full).
Public propertyDeviceThisMotorIsOn Returns the device that the MotorBase is attached to.
(Inherited from MotorBase)
Public propertyIsLastDirectionCloseFeedback Property to indicate that the current direction of movement is Close (momentary, full or jog).

The BaseEvent event will trigger with LastDirectionIsCloseEventId.


(Inherited from DinMotor)
Public propertyIsLastDirectionOpenFeedback Property to indicate that the current direction of movement is Open (momentary, full or jog).

The BaseEvent event will trigger with LastDirectionIsOpenEventId.


(Inherited from DinMotor)
Public propertyIsMovingFeedback Property to indicate that the motor has received an Open or Close command (momentary, full or jog).

The BaseEvent event will trigger with IsMovingEventId.


(Inherited from DinMotor)
Public propertyMotorState Property to set the Motor State and to get the current Motor State. Stop to be invoked to abort the current operation.
(Inherited from DinMotor)
Public propertyNumber Number of this Motor.
(Inherited from MotorBase)
Public propertyOpenMomentaryFull Opens the shade group toward the full open position for as long as the value is true (open momentary) and stops on release. If the property value changes from true to false within 0.5 seconds, then the shades open to the full open position (open full).
Public propertyParameterJogTime Parameter to set the time in milli seconds that the motor will move during a jog open or jog close operation. Value range is from 0.05 seconds to 2 seconds for "ClciMcex". 1 second is represented as 100.
(Inherited from MotorBase)
Public propertyParameterLockoutTime Parameter to set the minimum time that the motor must remain in the stop state before changing directions between open and close. Value range is from 0.2 to 2 seconds for "ClciMcex". 1 second is represented as 100.
(Inherited from MotorBase)
Public propertyParameterMaximumTime Parameter to set the maximum time in milli seconds that the motor can move in the open or close direction. Value range is from 1 to 360 seconds for "ClciMcex". 1 second is represented as 10.
(Inherited from MotorBase)
Public propertyParameterOverride Parameter to specify the corresponding motor state to recall in the event the unit enters override. Refer eDinMotorOverride for the valid values. This parameter is not supported by ClciMcexClciMcexMotorController.
(Inherited from DinMotor)
Public propertyParameterSlaveSwitchType Specifies whether a maintained or momentary slave switch is connected to the unit. Maintained is the default.