HdXspAmplifierStatusTemperatureHighFeedback Property |
Indicates if the temperature is too high. The temperature is considered too high if device temperature exceeds 85C OR the channel temperature exceeds 95C.
When this output is 'true' the amplifier's power turns off. Power is restored when both the device temperature AND channel temperature drop below 75C.
'true' = temperature is high; 'false' = Normal Temperature
The AmplifierStatusChange event will trigger with TemperatureHighFeedbackEventId.
Namespace: Crestron.SimplSharpPro.MediaAssembly: Crestron.SimplSharpPro.Media (in Crestron.SimplSharpPro.Media.dll) Version: 2.21.121
Syntaxpublic BoolOutputSig TemperatureHighFeedback { get; }Property Value
BoolOutputSigVersion Information
.NET