Hd |
The HdXspAmplifierStatus type exposes the following members.
| Name | Description | |
|---|---|---|
| OutputChannels | Collection of amplified output channels for the HdXspa. | |
| Parent | The parent that a given object was added to. | |
| TemperatureFeedback |
Reports the overall temperature, when temperature reporting is enabled.
If the format is Celsius the reported values will range from 0 to 1250 ( 0°C to 125°C), where 1 = 0.1 degree. If the format is Fahrenheit the reported values will range from 320 to 2570 (32°F to 257°F), where 1 = 0.1 degree. The AmplifierStatusChange event will trigger with TemperatureFeedbackEventId. | |
| TemperatureFormat |
Sets the format for internal amplifier temperature reporting. When 'false', the format is set to Celsius; when 'true', Fahrenheit.
'true' = Fahrenheit; 'false' = Celsius. | |
| TemperatureFormatFeedback |
Indicates the temperature format. The output remains 'true' for as long as the format is set to Fahrenheit. When the output is 'false', this indicates that the format is set to Celsius.
The AmplifierStatusChange event will trigger with TemperatureFormatFeedbackEventId. | |
| TemperatureHighFeedback |
Indicates if the temperature is too high. The temperature is considered too high if device temperature exceeds 85C OR the channel temperature exceeds 95C.
When this output is 'true' the amplifier's power turns off. Power is restored when both the device temperature AND channel temperature drop below 75C.
'true' = temperature is high; 'false' = Normal Temperature The AmplifierStatusChange event will trigger with TemperatureHighFeedbackEventId. | |
| TemperatureReportingEnabledFeedback |
Indicates the status of temperature reporting. The output remains 'true' for as long as temperature reporting is enabled; when 'false', this indicates that temperature reporting is disabled.
The AmplifierStatusChange event will trigger with TemperatureReportingEnabledFeedbackEventId. | |
| UserSpecifiedObject | Can be assigned anything that user wants. |