Click or drag to resize

HdXspAmplifierStatus Class

Class that represents the available status information of the amplifier on the HdXspa.

This class will trigger the AmplifierStatusChange event.

Inheritance Hierarchy
SystemObject
  Crestron.SimplSharpPro.MediaHdXspAmplifierStatus

Namespace: Crestron.SimplSharpPro.Media
Assembly: Crestron.SimplSharpPro.Media (in Crestron.SimplSharpPro.Media.dll) Version: 2.21.121
Syntax
C#
public class HdXspAmplifierStatus : IParentInformation

The HdXspAmplifierStatus type exposes the following members.

Properties
 NameDescription
Public propertyOutputChannels Collection of amplified output channels for the HdXspa.
Public propertyParent The parent that a given object was added to.
Public propertyTemperatureFeedback Reports the overall temperature, when temperature reporting is enabled.

If the format is Celsius the reported values will range from 0 to 1250 ( 0°C to 125°C), where 1 = 0.1 degree.

If the format is Fahrenheit the reported values will range from 320 to 2570 (32°F to 257°F), where 1 = 0.1 degree.

The AmplifierStatusChange event will trigger with TemperatureFeedbackEventId.

Public propertyTemperatureFormat Sets the format for internal amplifier temperature reporting. When 'false', the format is set to Celsius; when 'true', Fahrenheit.

'true' = Fahrenheit; 'false' = Celsius.

Public propertyTemperatureFormatFeedback Indicates the temperature format. The output remains 'true' for as long as the format is set to Fahrenheit. When the output is 'false', this indicates that the format is set to Celsius.

The AmplifierStatusChange event will trigger with TemperatureFormatFeedbackEventId.

Public propertyTemperatureHighFeedback Indicates if the temperature is too high. The temperature is considered too high if device temperature exceeds 85C OR the channel temperature exceeds 95C. When this output is 'true' the amplifier's power turns off. Power is restored when both the device temperature AND channel temperature drop below 75C.

'true' = temperature is high; 'false' = Normal Temperature

The AmplifierStatusChange event will trigger with TemperatureHighFeedbackEventId.

Public propertyTemperatureReportingEnabledFeedback Indicates the status of temperature reporting. The output remains 'true' for as long as temperature reporting is enabled; when 'false', this indicates that temperature reporting is disabled.

The AmplifierStatusChange event will trigger with TemperatureReportingEnabledFeedbackEventId.

Public propertyUserSpecifiedObject Can be assigned anything that user wants.
Top
Methods
 NameDescription
Public methodDisableTemperatureReporting Disables the TemperatureFeedback from reporting the internal amplifier temperature.
Public methodEnableTemperatureReporting Enables the TemperatureFeedback to report the internal amplifier temperature.
Public methodEqualsDetermines whether the specified object is equal to the current object.
(Inherited from Object)
Protected methodFinalizeAllows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection.
(Inherited from Object)
Public methodGetHashCodeServes as the default hash function.
(Inherited from Object)
Public methodGetTypeGets the Type of the current instance.
(Inherited from Object)
Protected methodMemberwiseCloneCreates a shallow copy of the current Object.
(Inherited from Object)
Public methodToString Return a string representing this HdXspAmplifierStatus.
(Overrides ObjectToString)
Top
Events
 NameDescription
Public eventAmplifierStatusChange Event triggered when new amplifier status has been reported to the control system.

Valid event IDs are available in HdXspAmplifierStatusEventIds.

Top

Version Information

.NET

Supported in: 6.0

.NET Compact Framework

Supported in: 3.5
See Also