The ChvTstat type exposes the following members.
| Name | Description | |
|---|---|---|
| _AUXBalancePoint |
Reports the aux balance point in tenths of a degree.
The scale (Fahrenheit or Celsius) is based on the current setting in the unit.
Values range from 0 to 900 (0?to 90?F); or -180 to +320 (-18?to 32?C).
The auxiliary balance point is the outdoor temperature above which auxiliary heat is locked out.
(Inherited from SingleSpeedFan) | |
| _CoolCallFeedbacks |
Returns a collection of components that indicate when the system is calling for cooling.
(Inherited from Thermostat) | |
| _CoolStages1 |
Indicates how many stages of cooling there are in the system.
(Inherited from SingleSpeedFan) | |
| _CoolStages2 |
Indicates how many stages of cooling there are in the system.
(Inherited from SingleSpeedFan) | |
| _CurrentSystemStateSlot |
Current system state slot device.
(Inherited from Thermostat) | |
| _DualFuelSubtype |
Indicates the current subtype for heating/cooling systems.
In dual-fuel setups, the auxiliary heat output runs in place of the heat pump in cold weather.
(Inherited from SingleSpeedFan) | |
| _FanCall |
Indicates that the fan is running (for any reason). Remains true for as long as the fan is running.
(Inherited from SingleSpeedFan) | |
| _FloorWarmSysModeHeat |
Turns the floor-warming system on.
(Inherited from SingleSpeedFan) | |
| _FloorWarmSysModeHeatFB |
Reports the status of the floor-warming system.
(Inherited from SingleSpeedFan) | |
| _FloorWarmSysModeOff |
Turns the floor-warming system off.
(Inherited from SingleSpeedFan) | |
| _FloorWarmSysModeOffFB |
Reports the status of the floor-warming system.
(Inherited from SingleSpeedFan) | |
| _ForceAirSubtype |
Indicates the current subtype for heating/cooling systems.
Forced air is a type of heating system that uses a blower motor to move air through the furnace and into the ductwork.
(Inherited from SingleSpeedFan) | |
| _HeatCallFeedbacks |
A collection of components that indicate when the system is calling for heat.
(Inherited from Thermostat) | |
| _HeatCoolControlSlot |
Heat/cool control slot device.
(Inherited from Thermostat) | |
| _HeatCoolType |
Indicates the current heat system type.
(Inherited from SingleSpeedFan) | |
| _HeatPumpType |
Indicates the current heat system type.
(Inherited from SingleSpeedFan) | |
| _HeatStages1 |
Indicates how many stages of heating there are in the system.
(Inherited from SingleSpeedFan) | |
| _HeatStages2 |
Indicates how many stages of heating there are in the system.
(Inherited from SingleSpeedFan) | |
| _HPBalancePoint |
Reports the heat pump balance point in tenths of a degree.
The scale (Fahrenheit or Celsius) is based on the current setting in the unit.
Values range from 0 to 900 (0?to 90?F); or -180 to +320 (-18?to 32?C).
The heat pump balance point is the outdoor temperature below which heat pump operation is locked out, and auxiliary heat runs in place of it.
(Inherited from SingleSpeedFan) | |
| _HumidityCallFeedbacks |
A collection of components that indicate when the system is calling for humidity.
(Inherited from SingleSpeedFan) | |
| _InterstageDifferential |
Reports the interstage differential in tenths of a degree.
This is the proportional temperature error to trigger the second (Auxiliary) stage.
The scale (Fahrenheit or Celsius) is based on the current setting in the unit.
Values range from 0.5 to 3.0 (5° to 30°F); or 0.25 to 2.0 (3° to 20°C).
(Inherited from SingleSpeedFan) | |
| _MaxSlabTemp |
Reports the maximum slab temperature value.
The scale (Fahrenheit or Celsius) is based on the current setting in the unit.
Values range from 390 to 1220 (39° to 122°F); or 44 to 500 (4° to 50°C).
(Inherited from SingleSpeedFan) | |
| _RadiantSubtype |
Indicates the current subtype for heating/cooling systems.
Radiant heating turns large areas (floor, walls, ceilings) into large surface radiators.
(Inherited from SingleSpeedFan) | |
| _Slab1Type |
Indicates the current slab system type.
(Inherited from SingleSpeedFan) | |
| _Slab2Type |
Indicates the current slab system type.
(Inherited from SingleSpeedFan) | |
| _Slab3Type |
Indicates the current slab system type.
(Inherited from SingleSpeedFan) | |
| _Slab4AType |
Indicates the current slab system type.
(Inherited from SingleSpeedFan) | |
| _Slab4BType |
Indicates the current slab system type.
(Inherited from SingleSpeedFan) | |
| _Slab5AType |
Indicates the current slab system type.
(Inherited from SingleSpeedFan) | |
| _Slab5BType |
Indicates the current slab system type.
(Inherited from SingleSpeedFan) | |
| _SlabControlSlot |
Slab control slot device.
(Inherited from SingleSpeedFan) | |
| _SlabMinSetpointMinus |
Lowers the slab regulating setpoint.
(Inherited from SingleSpeedFan) | |
| _SlabMinSetpointPlus |
Raises the slab regulating setpoint.
(Inherited from SingleSpeedFan) | |
| _SlabRegulation |
Reports the slab temperature regulation value. Values range from 1 to 6.
A lower number signifies less frequent cycles and slower response (looser regulation),
while a higher number signifies more frequent cycles and faster response (tighter regulation).
(Inherited from SingleSpeedFan) | |
| _SysModeAuxHeatOnly |
Selects the system mode.
(Inherited from SingleSpeedFan) | |
| _SystemConfigurationSlot |
System configuration slot device.
(Inherited from Thermostat) | |
| HTherm |
Humidity thermostat component of thermostat.
(Inherited from SingleSpeedFan) | |
| NumberOfAuxHeatStages |
The number of auxiliary heat stages on this device.
(Inherited from SingleSpeedFan) | |
| NumberOfCoolStages |
The number of cool stages on this device.
(Inherited from SingleSpeedFan) | |
| NumberOfHeatStages |
The number of heat stages on this device.
(Inherited from SingleSpeedFan) | |
| NumberOfHumidifierStages |
The number of humidity stages on this device.
(Inherited from SingleSpeedFan) | |
| NumberOfSlabHeatStages |
The number of slab heat stages on this device.
(Inherited from SingleSpeedFan) |