Click or drag to resize

HdXspOutputChannelStatusOverCurrentFeedback Property

Indicates that an Over Current fault condition has been detected at the corresponding channel.

An Over Current fault occurs when the amp is connected to a load that is drawing more than the rated power of the amp.

When 'false', this indicates a normal condition.

When the fault condition occurs the output will trigger and the amplifier (all channels) will turn off. The controller remains on. The amp will not start again until the fault condition is removed and the Reset button on the front panel is pressed. Pressing the Reset button will only clear the fault if it has been removed.

The AmplifierStatusChange event will trigger with OverCurrentFeedbackEventId.


Namespace: Crestron.SimplSharpPro.Media
Assembly: Crestron.SimplSharpPro.Media (in Crestron.SimplSharpPro.Media.dll) Version: 2.21.121
Syntax
C#
public BoolOutputSig OverCurrentFeedback { get; }

Property Value