HdXspOutputChannelStatus Properties

The HdXspOutputChannelStatus type exposes the following members.

Properties
 NameDescription
Public propertyChannel Get the channel that this object represents.
Public propertyClippingFeedback Indicates that the signal level at the corresponding channel has begun to clip. This signifies a signal level that is too hot.

The output remains 'true' for as long as the clipping condition exists. When 'false', this indicates a normal condition.

The AmplifierStatusChange event will trigger with ClippingFeedbackEventId.

Public propertyDcOffsetFeedback Indicates that a DC fault condition has been detected at the corresponding channel.

A DC fault may indicate an external wiring problem, e.g., speaker wires shorted to a live voltage.

When 'false', this indicates a normal condition.

When the fault condition occurs the output will trigger and the amplifier (all channels) will turn off. The device remains on. The amp will not start again until the fault condition is removed and the Reset button on the front panel is pressed. Pressing the Reset button will only clear the fault if it has been removed.

The AmplifierStatusChange event will trigger with DcOffsetFeedbackEventId.

Public propertyOverCurrentFeedback Indicates that an Over Current fault condition has been detected at the corresponding channel.

An Over Current fault occurs when the amp is connected to a load that is drawing more than the rated power of the amp.

When 'false', this indicates a normal condition.

When the fault condition occurs the output will trigger and the amplifier (all channels) will turn off. The controller remains on. The amp will not start again until the fault condition is removed and the Reset button on the front panel is pressed. Pressing the Reset button will only clear the fault if it has been removed.

The AmplifierStatusChange event will trigger with OverCurrentFeedbackEventId.

Public propertyOverOrUnderVoltageFeedback Indicates that an over/under voltage fault condition has been detected at the corresponding channel.

An over/under voltage fault indicates that the power supply voltage level at the corresponding channel is over or under the required level.

When 'false', this indicates a normal condition.

When the fault condition occurs the output will trigger and the amplifier (all channels) will turn off. The controller remains on. The amp will not start again until the fault condition is removed and the Reset button on the front panel is pressed. Pressing the Reset button will only clear the fault if it has been removed.

The AmplifierStatusChange event will trigger with OverOrUnderVoltageFeedbackEventId.