Clx |
The ClxMotor type exposes the following members.
| Name | Description | |
|---|---|---|
| DeviceThisMotorIsOn |
Returns the device that the MotorBase is attached to.
(Inherited from MotorBase) | |
| MotorState |
Property to set the Motor State and to get the current Motor State. "Stop" to be invoked to abort the current operation.
The valid states for ClxMotor are from Open to JogClose. If invalid state is set an ClxMotorStateInvalidException exception will be generated.
(Overrides MotorBaseMotorState) | |
| Number |
Number of this Motor.
(Inherited from MotorBase) | |
| ParameterJogTime |
Parameter to set the time in milli seconds that the motor will move during a jog open or jog close operation.
Value range is from 0.05 seconds to 2 seconds for "ClciMcex". 1 second is represented as 100.
(Inherited from MotorBase) | |
| ParameterLockoutTime |
Parameter to set the minimum time that the motor must remain in the stop state before changing directions between open and close.
Value range is from 0.2 to 2 seconds for "ClciMcex". 1 second is represented as 100.
(Inherited from MotorBase) | |
| ParameterMaximumTime |
Parameter to set the maximum time in milli seconds that the motor can move in the open or close direction.
Value range is from 1 to 360 seconds for "ClciMcex". 1 second is represented as 10.
(Inherited from MotorBase) |