Crestron. |
| Class | Description | |
|---|---|---|
| Axxess | Axxess family device class for ADA/PIC devices. | |
| AxxessADA | Axxess ADA object class. This class will trigger BaseEvent | |
| AxxessBase | Axxess family of devices base class for CCMD/GRM/HCM/HCMCM devices. | |
| AxxessCCMD | Axxess Communication and Control Module Digital device object class. This class will trigger BaseEvent | |
| AxxessGRM | Axxess group room management device object class. This class will trigger BaseEvent | |
| AxxessHCM | Axxess hallway chime module device object class. This class will trigger BaseEvent | |
| AxxessHCMCM | Axxess hallway chime monitor ceiling mount device object class. This class will trigger BaseEvent | |
| AxxessPIC | Axxess plug in chime device object class. This device does not remember the state of the Doorbell disabled state across reboots and must be triggered eveytime. This class will trigger BaseEvent | |
| C2nIo |
The C2N-IO is a compact Cresnet control module that adds control ports to any Crestron 2-Series or 3-Series control system.
This device does not support ComPort extended information events. | |
| C2nRths | A Cresnet based temperature and humidity sensor. | |
| CaenBlockCenCn2Poe | Crestron device that provides two independent cresnet control branches. | |
| CenIoCom | Base class for CEN-IO-COM-102. | |
| CenIoCom102 | Crestron external standalone serial COM card that provides RS-232 control interfaces for video displays, AV components, small applications, and other equipment. It includes two separate bidirectional RS-232 ports and communicates with the control system network via Ethernet. | |
| CenIoCom202 | Crestron external standalone serial COM card that provides RS-232 control interfaces for video displays, AV components, small applications, and other equipment. It includes two separate bidirectional RS-232 ports and communicates with the control system network via WiFi. | |
| CenIoDi | Base class for CEN-IO-DI-104. | |
| CenIoDi104 | Crestron external standalone Digital inputs card that provides digital input control interfaces for remote devices such as garage door openers, sensors, and motorized screens. It includes four digital input ports and communicates with the control system network via Ethernet. | |
| CenIoDi204 | Crestron external standalone Digital inputs card that provides digital input control interfaces for remote devices such as garage door openers, sensors, and motorized screens. It includes four digital input ports and communicates with the control system network via WiFi. | |
| CenIoIr | Base class for CEN-IO-IR-104. | |
| CenIoIr104 | Crestron external standalone IR Outputs card that provides IR remote control interfaces for video displays, AV components, small applications, and other equipment. It includes four discrete IR ports and communicates with the control system network via Ethernet. | |
| CenIoIr204 | Crestron external standalone IR Outputs card that provides IR remote control interfaces for video displays, AV components, small applications, and other equipment. It includes four discrete IR ports and communicates with the control system network via WiFi. | |
| CenIoRy | Base class for CEN-IO-RY-104. | |
| CenIoRy104 | Crestron external standalone Relays card that provides low-voltage relay control interfaces for remote devices such as garage door openers, sensors, and motorized screens. It includes four isolated relays and communicates with the control system network via Ethernet. | |
| CenIoRy204 | Crestron external standalone Relays card that provides low-voltage relay control interfaces for remote devices such as garage door openers, sensors, and motorized screens. It includes four isolated relays and communicates with the control system network via WiFi. | |
| CenOdtCPoe |
Ethernet-based dual technology sensor that uses passive infrared and ultrasonic technologies to detect occupancy.
This class will trigger BaseEvent and CenOccupancySensorChange events. | |
| CsaPws10sHub |
Power Supply with Cresnet interface that powers up to 10 Crestron Quiet Motor Technology roller
shade or drapery system motors and features a built-in, 5-segment Cresnet hub with network
diagnostics capabilities.
This class will trigger BaseEvent and BranchStateChange events. | |
| CsaPws10sHubEnet | Crestron device that provides two independent Cresnet control branches (local and master) as well as 5 separate power segments with 2 separate cresnet connectors on each segment that can be independently controlled. Valid Cresnet ID's for the master branch (branch 1) are 03 through 4F. Valid Cresnet ID's for the Local branch (branch 2) are 03 through 0C. | |
| CsaPws10sHubEnetBase | This base class is used for the CsaPws10sHubEnet and CsaPws10sHubEnetSlave. The CsaPws10sHubEnet is the an ethernet device, and the CsaPws10sHubEnetSlave is a device that can be dropped onto Cresnet or master/local branch of the CsaPws10sHubEnet. | |
| CsaPws10sHubEnetSegment |
Class containing information for each of the individual segments A-E (1-5) for the CsaPws10sHubEnet and CsaPws10sHubEnetSlave devices.
This class will trigger SegmentStateChange event. | |
| CsaPws10sHubEnetSegmentStateEventArgs | Event arguments class used for CsaPws10sHubEnetSegmentStateChangeEventHandler. | |
| CsaPws10sHubEnetSlave | Crestron device that provides 5 separate power segment with 2 separate Cresnet connectors on each segment that can be independently controlled. All devices plugged into this shade hub exist in the same Cresnet address space of the device it is attached to (for example, if this is on the main cresnet of an RMC3, you can access ID 03 through FE, excluding the Cresnet ID assigned to the hub itself. | |
| CsaPws10sHubEventIds | Class to define the valid EventIds for the BaseEvent and SegmentStateChange events. | |
| DinCenCn2 | Crestron device that provides two independent cresnet control branches. | |
| DinCenCn2Poe | Crestron device that provides two independent cresnet control branches. | |
| DinIo8 | Cresnet based device providing eight Versiports, programmable as digital inputs, digital outputs or analog outputs. Each Versiport has a corresponding pull-up resistor | |
| Ft2aCblr1t |
FT2A-CBLR-1T is a retractable cable management solution for Crestron® FT2 Series FlipTops™ which allows each cable to be pulled out smoothly for use,
and then retracted gently into its enclosure.
This class will trigger ButtonStateChange and BaseEvent events. | |
| GlsLcct |
Crestron SolarSync Outdoor Daylight and Color Temperature Sensor.
It measures true color temperature and intensity of natural sunlight or any other lighting source.
This class will trigger BaseEvent. | |
| GlsLdlExBatt | Battery-powered, dual-loop wireless photo sensor designed for daylight harvesting applications to control the balance of natural and artificial lighting in an indoor space. Dual-loop sensing is achieved on the device by two internal photocells—one for open-loop daylight sensing and one for closed-loop ambient light sensing. | |
| GlsOccupancySensorBase |
Base class for GLS Occupancy Sensors.
This class will trigger BaseEvent and GlsOccupancySensorChange events. | |
| GlsOccupancySensorChangeEventArgs | Event Argument class used for GlsOccupancySensorChangeEventHandler. | |
| GlsOdtCCn | Cresnet-based dual technology sensor that uses passive infrared and ultrasonic technologies to detect occupancy. | |
| GlsOirCCn |
Cresnet-based passive infrared (PIR) occupancy sensor.
This class will trigger BaseEvent and GlsOccupancySensorChange event. | |
| GlsOirCsmExBatt |
infiNET EX battery-powered occupancy sensor that uses passive infra-red to detect occupancy.
This class will trigger BaseEvent event with event IDs from GlsOirCsmExBattEventIds. | |
| GlsOirCsmExBattEventIds | Event Ids used on the GlsOirCsmExBatt that will trigger the BaseEvent event. | |
| GlsOirLclCCn |
Cresnet-based passive infrared (PIR) occupancy sensor without the external ambient light level.
This class will trigger BaseEvent and GlsOccupancySensorChangeevent. | |
| GlsPartCn | A Cresnet based partition sensor that uses a reflected IR beam to detect the presence of a partition wall. The sensor is powered from the 24V Cresnet bus and has the ability to adjust the detection distance of the wall partition. | |
| GlsSim | Cresnet based compact interface device designed to allow Crestron Green Light sensors to be connected directly to a Cresnet control network, with 2 Versiports. | |
| InetIoexIrcom | Compact infiNET EX Wireless IR/RS-232 control interface | |
| InetIoexRyio | Compact infiNET EX Wireless Relay/Digital Input control interface | |
| InetsIoexDoorBatt |
Battery operated compact infiNET EX Wireless door sensor.
This class will trigger BaseEvent event. | |
| IoexComOverflowControls | Extender used to detect COM overflow conditions of the IOEX. | |
| ShadePowerSupplyBranch |
Power Supply Hub ShadePowerSupplyBranch class
This class will trigger BranchStateChange event. | |
| ShadePowerSupplyBranchStateEventArgs | Event arguments class used for ShadePowerSupplyBranchStateChangeEventHandler. | |
| StatusSign |
LED back lit room sign that can be controlled via Cresnet.
This class will trigger BaseEvent event. | |
| StatusSignLed |
LED Class for StatusSign LED Control sigs.
This class will trigger BaseEvent events. | |
| StCom | The ST-COM provides two COM ports for controlling serial devices over RS-232, RS-424, or RS-485. This device has to receive string and CTS as feedbacks. | |
| StIo | The ST-IO provides eight isolated relays for controlling low voltage contact closure devices such as drapes, screens and lifts. It also provides four local digital inputs. The feedbacks for relay ports are simulated. |
| Interface | Description | |
|---|---|---|
| ICommonOccupancySensorInfo | Interface to describe the common Occupancy Sensor Info for GlsOccupancySensorBase, GlsOirCsmExBatt and GlppBase. | |
| IGlsCenOcc | Interface to define the common sigs between GLS and CEN-ODT-C-POE Occupancy Sensors. | |
| IGlsOccupancySensorsCommonSigs | Interface to describe the common sigs for GLS Occupancy Sensors. GlsOccupancySensorBase or GlsOirCsmExBatt. |
| Delegate | Description | |
|---|---|---|
| CsaPws10sHubEnetSegmentStateChangeEventHandler | Delegate to define the event handler for changes individual hub segments. | |
| GlsOccupancySensorChangeEventHandler | Delegate definition for GlsOccupancySensorChange event. | |
| ShadePowerSupplyBranchStateChangeEventHandler | Delegate to define the event handler for changes to the power supply hub branch. |
| Enumeration | Description | |
|---|---|---|
| eCsaPws10sHubEnetPowerSupplyErrorStatus | Enum which defines the values of the PowerSupplyErrorStatusFeedback property on the CsaPws10sHubEnet and CsaPws10sHubEnetSlave devices. | |
| eCsaPws10sHubEnetSegmentStatus | Enum to define the status on the segments on the CsaPws10sHubEnet and CsaPws10sHubEnetSlave devices. The enum represents bitfields that can be tested for. For example, if Y and Z are both shorted to ground the value returned will be 0x0022. | |
| eCsaPws10sHubEnetStatus | Enum which defines the values of the HubStatusFeedback property on the CsaPws10sHubEnet and CsaPws10sHubEnetSlave devices | |
| eGlsDataRefreshRate | Enum to define the data refresh rates. | |
| eSensitivityLevel | Enum to define the Sensitivity levels for ultrasonic (US) and passive infrared (PIR) while sensor is in occupied or vacant states. | |
| GlsLccteColorSpaceOutputType | Enum to define the Color Space Output Types | |
| GlsLccteLuxScaledRange | Enum to define the Lux Scaled Ranges | |
| StatusSignLedeBrightnessPercentageValues | Enum to define valid Brightness Percentage values. | |
| StatusSignLedeLedColor | Enum to define the LED colors for StatusSign. |