Zummesh |
The ZummeshNetbridge type exposes the following members.
| Name | Description | |
|---|---|---|
| BatteryLowFeedback |
Property to get the collection of devices whose battery level is low.
For the device info refer ZummeshNetbridgeDeviceInfo class.
The BaseEvent event will trigger with BatteryLowFeedbackEventId. | |
| BluetoothPinFeedback |
Property to report the pin for the bluetooth device.
This is the current 4-digit access code needed by a Bluetooth device to access this unit via Bluetooth
The default pin on the device is 2468.
The BaseEvent event will trigger with BluetoothPinFeedbackEventId. | |
| CctZone | Collection of CCT zones. Property to set/get values for CCT Zones. | |
| ConnectedIpList |
A property containing the list of the ConnectedIpInformation objects which contain information about the devices that are connected to this IP ID.
This property is only valid for an ethernet device. If this is not an ethernet device, then this property will return null.
If this is an ethernet device, the list will be non-null. It will be empty if no devices are connected.
The order of items in this list is not guaranteed.
(Inherited from GenericDevice) | |
| CurrentDaylightLevelFeedback |
Property to report the daylight level reported to the room's devices by the daylight sensor, if there is one.
The BaseEvent event will trigger with CurrentDaylightLevelFeedbackEventId. | |
| CurrentErrorsFeedback |
Property to return error log messages from the room, as they begin communicating with the room network.
The BaseEvent event will trigger with CurrentErrorsFeedbackEventId. | |
| CurrentTimeoutFeedback | Property to indicate which timeout is being used by the sensor. This property is not supported by ZummeshNetbridge. | |
| DaylightingEnabledFeedback |
Property to indicate if daylighting (daylight harvesting) is enabled in the room. This property will be
updated when Activate method is called for scene1 or when
DisableDaylighting or RoomAllOff methods are called or when Activate method is called for scenes 2-16.
The BaseEvent event will trigger with DaylightingEnabledEventId. | |
| Description |
Get/Set the description of this device.
(Inherited from GenericBase) | |
| DeviceListFeedback |
Property to get the collection of devices that are communicating with the network.
For the device info refer ZummeshNetbridgeDeviceInfo class.
The BaseEvent event will trigger with DeviceListFeedbackEventId. | |
| Disposed |
Property to indicate if the device has been disposed.
(Inherited from GenericDevice) | |
| EUIDFeedback |
Property to report the unique identifier of the device.
The BaseEvent event will trigger with EUIDFeedbackEventId. The minimum firmware version on the device which supports this property is v1.008.0001. | |
| ExportIdFeedback |
Property to return the export ID.
The BaseEvent event will trigger with ExportIdFeedbackEventId. The minimum firmware version on the device which supports this property is 1.014.0001. | |
| FirmwareLoadSuspendedFeedback |
Feedback to reflect the firmware loading state of the device.
The BaseEvent event will trigger with FirmwareLoadingSuspendedFeedbackEventId. | |
| FirmwareUpdateStatusFeedback |
Feedback to reflect the the overall upgrade status of a room
A value of false indicates that the system is idle, all updates completed or never requested since a bridge reboot which happens after bridge upgrades itself.
A value of true indicates that the update is pending.
The BaseEvent event will trigger with FirmwareUpdateStatusFeedbackEventId. The minimum firmware version on the device which supports this property is v1.008.0001. | |
| FloorIdFeedback |
Property to return the current floor Id.
The BaseEvent event will trigger with FloorIdFeedbackEventId. The minimum firmware version on the device which supports this property is v1.008.0001. | |
| FloorLabels | Property to get the collection of floor labels. | |
| ID |
Property to get the ID of the device.
(Inherited from GenericDevice) | |
| IsOnline |
Property to get the current online state of the device.
(Inherited from GenericDevice) | |
| LoadShedEnable | Property to enable/disable Load Shedding. When "true" will enable Load Shedding. When set to "false", Load Shedding is disabled. This sends a signal to every load controller in the room telling it to go into Load Shedding mode. Basically Load Shedding Mode is a state where there is an alternate MAXimum value imposed on the dimmers as specified by LoadShedMaxLevel. For switch type controllers, it may tell the device that it needs to be off when Load Shedding is enabled. The minimum firmware version on the device which supports this property is v1.009.0012. | |
| LoadShedMaxLevel | Property to set the sets the maximum level of all dimmers. Used during load shedding to limit peak load which can cut on electricity costs. Valid range is 0 to 100. 0 being dimmer is off and 100 being max level. Default value is a 100. Use the "SimplSharpDeviceHelper.UshortToPercent" to convert the ushort value to percentage. The minimum firmware version on the device which supports this property is v1.008.0001. | |
| MissingDevicesFeedback |
Property to get the collection of devices that have disappeared from the network.
For the device info refer ZummeshNetbridgeDeviceInfo class.
The BaseEvent event will trigger with MissingDevicesFeedbackEventId. | |
| Name |
Get the name of this device.
(Inherited from GenericBase) | |
| NumberOfDevicesFeedback |
Property to report the current number of active devices in the room. Reports each time the number changes.
The BaseEvent event will trigger with NumberOfDevicesFeedbackEventId. | |
| OccupancyDetectedFeedback |
Property to indicate if the room's logic determined that the room is occupied. Either from the sensors, or direct command.
The BaseEvent event will trigger with RoomOccupiedEventId. | |
| OccupancySensorEnabledFeedback |
Property to indicate if the room is instructed to act upon occupancy sensor events. Follows the calls to EnableOccupancySensor and DisableOccupancySensor methods.
The BaseEvent event will trigger with OccupancySensorEnabledEventId. | |
| Parent |
The parent that a given object was added to.
(Inherited from GenericBase) | |
| PlugControllerStatusFeedback |
Feedback to reflect the status of all the plug loads on the controller.
The BaseEvent event will trigger with PlugControllerStatusFeedbackEventId. The minimum firmware version on the device which supports this property is v1.008.0001. | |
| Registerable |
Property to indicate that this device can be registered.
(Inherited from GenericDevice) | |
| Registered |
Property to get the current registration state of the device.
(Inherited from GenericDevice) | |
| RegistrationFailureReason |
Property to get the Registration Failure Reason, this will match the return value from the call to register.
(Inherited from GenericDevice) | |
| RemoteTimeout | Property to set timeout remotely. This property is not supported by ZummeshNetbridge. | |
| ResumeFirmwareLoad | Property to resume the firmware load operation on the controller. This will resume any pending updates on the device. The FirmwareLoadSuspendedFeedback will trigger to reflect the state of the controller. | |
| RoomIsOnFeedback |
Property to indicate if atleast one of the lights in the room is on.
The BaseEvent event will trigger with RoomIsOnEventId. | |
| RoomName | Property to set the name this bridge reports the room as. The string will also be stored in NV memory. | |
| RoomNameFeedback |
Property to report the name assigned to the room back to the control system.
The BaseEvent event will trigger with RoomNameFeedbackEventId. | |
| Scenes |
Collection of ZummeshNetbridgeZummeshNetbridgeScene class object.
This property will trigger BaseEvent with SceneActiveEventId. | |
| SIMPLDeviceImplementation |
Internal protected member used for actual device control.
(Inherited from GenericDevice) | |
| SolarSynchronizeActive | Property to enable/disable Solar Synchronize. Setting to 'True' enables Solar Synchronize, setting to 'False' will disable Solar Synchronize. | |
| SolarSynchronizeActiveFeedback |
Property to report the solar synchronize status.
True indicates solar synchronize is active, False indicates solar synchronize is deactive.
The BaseEvent event will trigger with SolarSynchronizeActiveFeedbackEventId. | |
| SuspendFirmwareLoad | Property to suspend the firmware load operation on the controller. This will suspend any pending updates on the device as long as the property is set to true. Setting the property to false will resume any pending updates. The FirmwareLoadSuspendedFeedback will trigger to reflect the state of the controller. | |
| Type |
Property to determine to type of device this is.
(Inherited from GenericDevice) | |
| UnRegistrationFailureReason |
Property to get the Unregistration Failure Reason, this will match the return value from the call to unregister.
(Inherited from GenericDevice) | |
| UserSpecifiedObject |
Can be assigned anything that user wants.
(Inherited from GenericBase) | |
| VersionFeedback |
Property to report the version of the device.
The BaseEvent event will trigger with VersionFeedbackEventId. The minimum firmware version on the device which supports this property is v1.009.0012. | |
| XioEndpointStubSIMPLDevice |
The SIMPL "stub" Device that the XiO Director creates for an endpoint to send the 1C/0E to the
correct place in hierarchy.
(Inherited from GenericDevice) | |
| ZoneIdFeedback |
Property to return the current zone Id.
The BaseEvent event will trigger with ZoneIdFeedbackEventId. The minimum firmware version on the device which supports this property is v1.008.0001. |