Pc |
The Pc300 type exposes the following members.
| Name | Description | |
|---|---|---|
| ConnectedIpList |
A property containing the list of the ConnectedIpInformation objects which contain information about the devices that are connected to this IP ID.
This property is only valid for an ethernet device. If this is not an ethernet device, then this property will return null.
If this is an ethernet device, the list will be non-null. It will be empty if no devices are connected.
The order of items in this list is not guaranteed.
(Inherited from GenericDevice) | |
| DataLoggingFeedback |
Property to indicate that logging to internal filesystem is enabled (true) or disabled (false).
The BaseEvent event will trigger with DataLoggingFeedbackEventId. (Inherited from PcX00) | |
| Description |
Get/Set the description of this device.
(Inherited from GenericBase) | |
| Disposed |
Property to indicate if the device has been disposed.
(Inherited from GenericDevice) | |
| FrontPanelDisplayBrightness |
Property to set the Front Panel Display Brightness
Valid range is 0 to 65535. Please use thePercentToUshort(Single)to convert
the percentage to a ushort value
(Inherited from PcX00) | |
| FrontPanelDisplayBrightnessFeedback |
Property to report the Front Panel Display Brightness
The BaseEvent event will trigger with FrontPanelDisplayBrightnessFeedbackEventId. Valid range is 0 to 65535. Please use theUshortToPercent(UInt16)to convert the ushort to a percentage value.(Inherited from PcX00) | |
| FrontPanelDisplayFeedback |
Property to indicate that the front panel display is ON (true) or OFF (false).
The BaseEvent event will trigger with FrontPanelDisplayFeedbackEventId. (Inherited from PcX00) | |
| FrontPanelLockFeedback |
Property to indicate that the front panel is locked (true) or unlocked (false).
The BaseEvent event will trigger with FrontPanelLockFeedbackEventId. (Inherited from PcX00) | |
| HostnameOrIPAddressToPing | Obsolete. Property to set the Hostname or IP address of the device to ping. This specifies the device to ping and if the ping fails then the outlet specified by OutletToShutdownOnPingFailure is turned off and on. (Inherited from PcX00) | |
| HostnameOrIPAddressToPingFeedback | Obsolete. Property to return the Hostname or IP address of device to ping. The BaseEvent event will trigger with HostnameOrIPAddressToPingFeedbackEventId. (Inherited from PcX00) | |
| ID |
Property to get the ID of the device.
(Inherited from GenericDevice) | |
| InputCurrentFeedback |
Property to report the total RMS Current reading in Amps.
The BaseEvent event will trigger with InputCurrentFeedbackEventId. (Inherited from PcXxx) | |
| InputEnergyFeedback |
Property to report the Energy reading converted to an integer from a 9-digit decimal string format.
This property is valid for Pc200, CresnetPc200, "Pc350v12", "CresnetPc350v12" "Pc350v18" and "CresnetPc350v18" devices only, return value is 0 otherwise.
The BaseEvent event will trigger with InputEnergyFeedbackEventId. (Inherited from PcXxx) | |
| InputEnergyFeedbackRaw |
Property to report the Energy reading formatted as a 9-digit decimal string.
This property is valid for Pc200, CresnetPc200, "Pc350v12", "CresnetPc350v12" "Pc350v18" and "CresnetPc350v18" devices only.
The BaseEvent event will trigger with InputEnergyFeedbackEventId. (Inherited from PcXxx) | |
| InputPowerFeedback |
Property to report the Power reading in Watts.
This property is valid for Pc200, CresnetPc200, "Pc350v12", "CresnetPc350v12" "Pc350v18" and "CresnetPc350v18" devices only.
The BaseEvent event will trigger with InputPowerFeedbackEventId. (Inherited from PcXxx) | |
| InputVoltageFeedback |
Property to report the latest RMS voltage reading in volts.
The BaseEvent event will trigger with InputVoltageFeedbackEventId. (Inherited from PcXxx) | |
| IsOnline |
Property to get the current online state of the device.
(Inherited from GenericDevice) | |
| Name |
Get the name of this device.
(Inherited from GenericBase) | |
| OutletBanks |
Collection of OutletBanks this power condition can control.
(Inherited from PcXxx) | |
| OutletToShutdownOnPingFailure | Obsolete. Property to get/set the outlet bank to shutdown on a ping failure. The get returns the last value which was set and not the feedback OutletToShutdownOnPingFailureFeedback reported by the device (Inherited from PcX00) | |
| OutletToShutdownOnPingFailureFeedback | Obsolete. Property to report the outlet bank to shutdown on a ping failure. The BaseEvent event will trigger with OutletToShutdownOnPingFailureFeedbackEventId. This always reports the last outlet value(Inherited from PcX00) | |
| OverCurrentCutoff |
Property to set the high RMS current limit in Amps. Automatic shutdown when total current is above this threshold.
(Inherited from PcXxx) | |
| OverCurrentCutoffFeedback |
Property to report the high RMS current limit in Amps.
The BaseEvent event will trigger with OverCurrentCutoffFeedbackEventId. (Inherited from PcXxx) | |
| OverCurrentFeedback |
Property to indicate that a over current condition detected.
The BaseEvent event will trigger with OverCurrentFeedbackEventId. (Inherited from PcXxx) | |
| OverVoltageCutoff |
Property to set the high RMS voltage limit in volts. Automatic shutdown when voltage is above this threshold.
(Inherited from PcXxx) | |
| OverVoltageCutoffFeedback |
Property to report the high RMS voltage limit in volts.
The BaseEvent event will trigger with OverVoltageCutoffFeedbackEventId. (Inherited from PcXxx) | |
| OverVoltageFeedback |
Property to indicate that a over voltage condition detected.
The BaseEvent event will trigger with OverVoltageFeedbackEventId. (Inherited from PcXxx) | |
| Parent |
The parent that a given object was added to.
(Inherited from GenericBase) | |
| PingFailureFeedback |
Property to indicate that a ping attempt has failed.
This property is not valid for "Pc350v12", "CresnetPc350v12" "Pc350v18" and "CresnetPc350v18" devices.
The BaseEvent event will trigger with PingFailureFeedbackEventId. (Inherited from PcX00) | |
| PingFailureReportingFeedback | Obsolete. Property to indicate that reporting of ping failure is enabled (true) or disabled (false). The BaseEvent event will trigger with PingFailureReportingFeedbackEventId. (Inherited from PcX00) | |
| PingInterval |
Property to set the delay between ping attempts in minutes.
(Inherited from PcX00) | |
| PingIntervalFeedback |
Property to report the delay between ping attempts in seconds.
The BaseEvent event will trigger with PingIntervalFeedbackEventId. (Inherited from PcX00) | |
| PingMonitorEnabledFeedback |
Property to indicate if the ping monitor feature is enabled (true) or disabled (false).
The BaseEvent event will trigger with PingMonitorEnabledFeedbackEventId. (Inherited from PcX00) | |
| PowerCycleDelay |
Property to set the power cycle delay. This is the time in seconds, the outlets will be turned off
when the PowerCycle or PowerCycle method is called.
(Inherited from PcX00) | |
| PowerCycleDelayFeedback |
Property to report the power cycle delay. This is the time in seconds, the outlets will be turned off
when the PowerCycle or PowerCycle method is called.
The BaseEvent event will trigger with PowerCycleDelayFeedbackEventId. (Inherited from PcX00) | |
| PowerCycleFeedback |
Property to indicate that the power is being cycled to all the outlets.
The BaseEvent event will trigger with PowerCycleFeedbackEventId. This property will stay true for the time defined by the PowerCycleDelay property.(Inherited from PcX00) | |
| PowerSwitchOnFeedback |
Property to indicate that the front panel power switch is activated.
The BaseEvent event will trigger with PowerSwitchOnFeedbackEventId. (Inherited from PcX00) | |
| ProtectionCompromisedFeedback |
Property to indicate that the surge protection has failed.
The BaseEvent event will trigger with ProtectionCompromisedEventId. (Inherited from PcXxx) | |
| Registerable |
Property to indicate that this device can be registered.
(Inherited from GenericDevice) | |
| Registered |
Property to get the current registration state of the device.
(Inherited from GenericDevice) | |
| RegistrationFailureReason |
Property to get the Registration Failure Reason, this will match the return value from the call to register.
(Inherited from GenericDevice) | |
| SamplingInterval |
Property to set the interval between join updates and log entries in seconds.
(Inherited from PcX00) | |
| SamplingIntervalFeedback |
Property to report the interval between join updates and log entries in seconds.
The BaseEvent event will trigger with SamplingIntervalFeedbackEventId. (Inherited from PcX00) | |
| ShowOutletControlMenuFeedback |
Property to indicate that outlet control menu is enabled on the top level (true) or is hidden (false).
The BaseEvent event will trigger with ShowOutletControlMenuFeedbackEventId. (Inherited from PcX00) | |
| SIMPLDeviceImplementation |
Internal protected member used for actual device control.
(Inherited from GenericDevice) | |
| SurgeDetectedFeedback |
Property to indicate that the surge protection failure is detected.
This property is not valid for "Pc350v12", "CresnetPc350v12" "Pc350v18" and "CresnetPc350v18" devices.
The BaseEvent event will trigger with SurgeProtectionFeedbackEventId. (Inherited from PcX00) | |
| TemperatureFeedback |
Property to report the latest temperature reading in Celsius/Fahrenheit.
The BaseEvent event will trigger with TemperatureFeedbackEventId. (Inherited from PcXxx) | |
| TemperatureFormatReportingFeedback |
Property to indicate that the temperature is specified and reported in Celsius (true) or fahrenheit (false).
The BaseEvent event will trigger with TemperatureFormatReportingFeedbackEventId. (Inherited from PcX00) | |
| TemperatureHighCutoff |
Property to set high temperature limit. Automatic shutdown when temperature is above this threshold.
(Inherited from PcX00) | |
| TemperatureHighCutoffFeedback |
Property to report the high temperature limit.
The BaseEvent event will trigger with TemperatureHighCutoffFeedbackEventId. (Inherited from PcX00) | |
| TemperatureOverRangeFeedback |
Property to indicate that the temperature outside limits.
This property is not valid for "Pc350v12", "CresnetPc350v12" "Pc350v18" and "CresnetPc350v18" devices.
The BaseEvent event will trigger with TemperatureOverRangeFeedbackEventId. (Inherited from PcX00) | |
| TemperatureReadingValidFeedback |
Property to indicate that the temperature readings are valid.
This property is not valid for "Pc350v12", "CresnetPc350v12" "Pc350v18" and "CresnetPc350v18" devices.
The BaseEvent event will trigger with TemperatureReadingValidFeedbackEventId. (Inherited from PcX00) | |
| Type |
Property to determine to type of device this is.
(Inherited from GenericDevice) | |
| UnderVoltageCutoff |
Property to set the low RMS voltage limit in volts. Automatic shutdown when voltage is below this threshold.
(Inherited from PcXxx) | |
| UnderVoltageCutoffFeedback |
Property to report the low RMS voltage limit in volts.
The BaseEvent event will trigger with UnderVoltageCutoffFeedbackEventId. (Inherited from PcXxx) | |
| UnderVoltageFeedback |
Property to indicate that an under voltage condition detected.
The BaseEvent event will trigger with UnderVoltageFeedbackEventId. (Inherited from PcXxx) | |
| UnRegistrationFailureReason |
Property to get the Unregistration Failure Reason, this will match the return value from the call to unregister.
(Inherited from GenericDevice) | |
| UserSpecifiedObject |
Can be assigned anything that user wants.
(Inherited from GenericBase) | |
| WiringFaultFeedback |
Property to indicate that wiring fault detected.
The BaseEvent event will trigger with WiringFaultEventId. (Inherited from PcXxx) | |
| XioEndpointStubSIMPLDevice |
The SIMPL "stub" Device that the XiO Director creates for an endpoint to send the 1C/0E to the