Click or drag to resize

PcXxx Class

Base class for PC-200, PC-300, PC-350V-12 and PC-350V-18 Power Conditioners.

This class will trigger BaseEvent

Inheritance Hierarchy

Namespace: Crestron.SimplSharpPro.GeneralIO.PowerConditioners
Assembly: Crestron.SimplSharpPro.GeneralIO (in Crestron.SimplSharpPro.GeneralIO.dll) Version: 2.21.121
Syntax
C#
public class PcXxx : GenericDevice

The PcXxx type exposes the following members.

Properties
 NameDescription
Public propertyConnectedIpList A property containing the list of the ConnectedIpInformation objects which contain information about the devices that are connected to this IP ID. This property is only valid for an ethernet device. If this is not an ethernet device, then this property will return null. If this is an ethernet device, the list will be non-null. It will be empty if no devices are connected. The order of items in this list is not guaranteed.
(Inherited from GenericDevice)
Public propertyCode exampleDescription Get/Set the description of this device.
(Inherited from GenericBase)
Public propertyDisposed Property to indicate if the device has been disposed.
(Inherited from GenericDevice)
Public propertyID Property to get the ID of the device.
(Inherited from GenericDevice)
Public propertyInputCurrentFeedback Property to report the total RMS Current reading in Amps.

The BaseEvent event will trigger with InputCurrentFeedbackEventId.

Public propertyInputEnergyFeedback Property to report the Energy reading converted to an integer from a 9-digit decimal string format. This property is valid for Pc200, CresnetPc200, "Pc350v12", "CresnetPc350v12" "Pc350v18" and "CresnetPc350v18" devices only, return value is 0 otherwise.

The BaseEvent event will trigger with InputEnergyFeedbackEventId.

Public propertyInputEnergyFeedbackRaw Property to report the Energy reading formatted as a 9-digit decimal string. This property is valid for Pc200, CresnetPc200, "Pc350v12", "CresnetPc350v12" "Pc350v18" and "CresnetPc350v18" devices only.

The BaseEvent event will trigger with InputEnergyFeedbackEventId.

Public propertyInputPowerFeedback Property to report the Power reading in Watts. This property is valid for Pc200, CresnetPc200, "Pc350v12", "CresnetPc350v12" "Pc350v18" and "CresnetPc350v18" devices only.

The BaseEvent event will trigger with InputPowerFeedbackEventId.

Public propertyInputVoltageFeedback Property to report the latest RMS voltage reading in volts.

The BaseEvent event will trigger with InputVoltageFeedbackEventId.

Public propertyIsOnline Property to get the current online state of the device.
(Inherited from GenericDevice)
Public propertyName Get the name of this device.
(Inherited from GenericBase)
Public propertyOutletBanks Collection of OutletBanks this power condition can control.
Public propertyOverCurrentCutoff Property to set the high RMS current limit in Amps. Automatic shutdown when total current is above this threshold.
Public propertyOverCurrentCutoffFeedback Property to report the high RMS current limit in Amps.

The BaseEvent event will trigger with OverCurrentCutoffFeedbackEventId.

Public propertyOverCurrentFeedback Property to indicate that a over current condition detected.

The BaseEvent event will trigger with OverCurrentFeedbackEventId.

Public propertyOverVoltageCutoff Property to set the high RMS voltage limit in volts. Automatic shutdown when voltage is above this threshold.
Public propertyOverVoltageCutoffFeedback Property to report the high RMS voltage limit in volts.

The BaseEvent event will trigger with OverVoltageCutoffFeedbackEventId.

Public propertyOverVoltageFeedback Property to indicate that a over voltage condition detected.

The BaseEvent event will trigger with OverVoltageFeedbackEventId.

Public propertyParent The parent that a given object was added to.
(Inherited from GenericBase)
Public propertyProtectionCompromisedFeedback Property to indicate that the surge protection has failed.

The BaseEvent event will trigger with ProtectionCompromisedEventId.

Public propertyRegisterable Property to indicate that this device can be registered.
(Inherited from GenericDevice)
Public propertyRegistered Property to get the current registration state of the device.
(Inherited from GenericDevice)
Public propertyRegistrationFailureReason Property to get the Registration Failure Reason, this will match the return value from the call to register.
(Inherited from GenericDevice)
Protected propertySIMPLDeviceImplementation Internal protected member used for actual device control.
(Inherited from GenericDevice)
Public propertyTemperatureFeedback Property to report the latest temperature reading in Celsius/Fahrenheit.

The BaseEvent event will trigger with TemperatureFeedbackEventId.

Public propertyType Property to determine to type of device this is.
(Inherited from GenericDevice)
Public propertyUnderVoltageCutoff Property to set the low RMS voltage limit in volts. Automatic shutdown when voltage is below this threshold.
Public propertyUnderVoltageCutoffFeedback Property to report the low RMS voltage limit in volts.

The BaseEvent event will trigger with UnderVoltageCutoffFeedbackEventId.

Public propertyUnderVoltageFeedback Property to indicate that an under voltage condition detected.

The BaseEvent event will trigger with UnderVoltageFeedbackEventId.

Public propertyUnRegistrationFailureReason Property to get the Unregistration Failure Reason, this will match the return value from the call to unregister.
(Inherited from GenericDevice)
Public propertyUserSpecifiedObject Can be assigned anything that user wants.
(Inherited from GenericBase)
Public propertyWiringFaultFeedback Property to indicate that wiring fault detected.

The BaseEvent event will trigger with WiringFaultEventId.

Protected propertyXioEndpointStubSIMPLDevice The SIMPL "stub" Device that the XiO Director creates for an endpoint to send the 1C/0E to the correct place in hierarchy.
(Inherited from GenericDevice)
Top
Methods
 NameDescription
Public methodDispose Clean up of resources.
(Inherited from GenericBase)
Protected methodDispose(Boolean) Method to perform the actual disposing of the device.
(Inherited from GenericDevice)
Public methodEqualsDetermines whether the specified object is equal to the current object.
(Inherited from Object)
Protected methodFinalize Destructor of the device.
(Inherited from GenericDevice)
Public methodGetHashCodeServes as the default hash function.
(Inherited from Object)
Public methodGetTypeGets the Type of the current instance.
(Inherited from Object)
Protected methodMemberwiseCloneCreates a shallow copy of the current Object.
(Inherited from Object)
Protected methodOnBaseEvent(Int32) Protected member used to fire the BaseEvent with the default extended information.
(Inherited from GenericBase)
Protected methodOnBaseEvent(Int32, UInt16) Protected member used to fine the BaseEvent with extended event information.
(Inherited from GenericBase)
Public methodPowerCycle Method to power cycle all the outlets. The outlets will stay off for the duration specified by the PowerCycleDelay property for Pc200, CresnetPc200, Pc300 and CresnetPc300.
Public methodRegister Register this device with the system.
(Inherited from GenericDevice)
Public methodResetEnergyCount Method to reset accumulated energy count for all outlets.
Public methodToString Return the name of the device.
(Inherited from GenericDevice)
Public methodUnRegister Unregister this device with the system. This function can not be called from the device's own SigChange event handler.

On successful unregistration, if this device supports the OnlineStatusChange event, it will trigger indicating the device when offline.


(Inherited from GenericDevice)
Top
Events
 NameDescription
Public eventBaseEvent Generic base event, triggered when the there are no other handlers available for a specific EventID.
(Inherited from GenericBase)
Public eventIpInformationChange Event that tells what IP Address is connected/disconnected from an IP ID for a non-UDP device. This is only valid for an Ethernet device. An exception will be thrown if it is not.
(Inherited from GenericDevice)
Public eventOnlineStatusChange Event triggered when the Online status of the device changes.
(Inherited from GenericDevice)
Top
Fields
 NameDescription
Public fieldNumberOfOutletBanks Number of OutletBank objects in the OutletBanks collection for this power conditioner.
Public fieldNumberOfPingMonitors Number of PingMonitor or "Pc350vPingMonitor" objects in the PingMonitors or "Pc350vPingMonitor" collection for this power conditioner.
Top

Version Information

.NET

Supported in: 6.0

.NET Compact Framework

Supported in: 3.5
See Also