Click or drag to resize

PingMonitor Class

Controls for an individual ping monitor that is part of the PcX00.

This class will trigger BaseEvent with events IDs defined in the PcX00 with Index is set to the corresponding monitor.

Inheritance Hierarchy
SystemObject
  Crestron.SimplSharpPro.GeneralIO.PowerConditionersPingMonitor

Namespace: Crestron.SimplSharpPro.GeneralIO.PowerConditioners
Assembly: Crestron.SimplSharpPro.GeneralIO (in Crestron.SimplSharpPro.GeneralIO.dll) Version: 2.21.121
Syntax
C#
public class PingMonitor : IParentInformation

The PingMonitor type exposes the following members.

Properties
 NameDescription
Public propertyOutlet Property to set the PingOutlet using the OutletBank from the PcX00 class.

On the Pc200, the OutletBank controls two outlets each. Due to this hardware design, when an Outlet is specified it will turn off two physical outlets.

To clear the current setting, pass in a value of 'null'

This is equlivant to setting the Raw value to that of the value of Number.

The specified OutletBank is not from the same PcX00 as this PingMonitor.
Public propertyOutletFeedback Property to indicate the currently set OutletBank that will shutdown on ping failure.

The BaseEvent event will trigger with OutletFeedbackEventId and Index gives the index into the PingMonitors collection.

This feature of the power condition is not available for the front panel outlet.

Public propertyOutletRaw Property to modify the outlet bank that will shutdown on ping failure.

On the Pc200, the OutletBank controls two outlets each. Due to this hardware design, when an Outlet is specified it will also turn off two outlets.

Valid values for the Pc200 are 0 to 3.

Valid values for the Pc300 are 0 to 8.

Public propertyOutletRawFeedback Property to indicate the currently set outlet bank number that will shutdown on ping failure.

The BaseEvent event will trigger with OutletFeedbackEventId and Index gives the index into the OutletBanks collection.

This feature of the power condition is not available for the front panel outlet.

Public propertyTarget The IP address or hostname of the device the power condition will ping in order to determine when the turn off the outlet specified by OutletFeedback.

This feature of the power condition is not available for the front panel outlet. SIMPL# Pro will not validate this input.

Public propertyTargetFeedback Property to indicate the currently set IP address of hostname of the device that will be pinged by the power conditioner to determine if the outlet specified by OutletFeedback will be turned off.

The BaseEvent event will trigger with TargetFeedbackEventId and Index gives the index into the OutletBanks collection.

This feature of the power condition is not available for the front panel outlet.

Public propertyUserSpecifiedObject Object that can be set to aid in development.
Top
Methods
 NameDescription
Public methodEqualsDetermines whether the specified object is equal to the current object.
(Inherited from Object)
Protected methodFinalizeAllows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection.
(Inherited from Object)
Public methodGetHashCodeServes as the default hash function.
(Inherited from Object)
Public methodGetTypeGets the Type of the current instance.
(Inherited from Object)
Protected methodMemberwiseCloneCreates a shallow copy of the current Object.
(Inherited from Object)
Public methodToStringReturns a string that represents the current object.
(Inherited from Object)
Top
Fields
 NameDescription
Public fieldNumber Number of this PingMonitor.
Public fieldParent Power conditioner that owns this PingMonitor.
Top

Version Information

.NET

Supported in: 6.0

.NET Compact Framework

Supported in: 3.5
See Also