Ping |
The PingMonitor type exposes the following members.
| Name | Description | |
|---|---|---|
| Outlet |
Property to set the PingOutlet using the OutletBank from the PcX00 class.
On the Pc200, the OutletBank controls two outlets each. Due to this hardware design, when an Outlet is specified it will turn off two physical outlets. To clear the current setting, pass in a value of 'null' This is equlivant to setting the Raw value to that of the value of Number. The specified OutletBank is not from the same PcX00 as this PingMonitor. | |
| OutletFeedback |
Property to indicate the currently set OutletBank that will shutdown on ping failure.
The BaseEvent event will trigger with OutletFeedbackEventId and Index gives the index into the PingMonitors collection. This feature of the power condition is not available for the front panel outlet. | |
| OutletRaw |
Property to modify the outlet bank that will shutdown on ping failure.
On the Pc200, the OutletBank controls two outlets each. Due to this hardware design, when an Outlet is specified it will also turn off two outlets. Valid values for the Pc200 are 0 to 3. Valid values for the Pc300 are 0 to 8. | |
| OutletRawFeedback |
Property to indicate the currently set outlet bank number that will shutdown on ping failure.
The BaseEvent event will trigger with OutletFeedbackEventId and Index gives the index into the OutletBanks collection. This feature of the power condition is not available for the front panel outlet. | |
| Target |
The IP address or hostname of the device the power condition will ping in order to determine when the turn off the outlet specified by OutletFeedback.
This feature of the power condition is not available for the front panel outlet. SIMPL# Pro will not validate this input. | |
| TargetFeedback |
Property to indicate the currently set IP address of hostname of the device that will be pinged by the power conditioner to determine if the outlet specified by OutletFeedback will be turned off.
The BaseEvent event will trigger with TargetFeedbackEventId and Index gives the index into the OutletBanks collection. This feature of the power condition is not available for the front panel outlet. | |
| UserSpecifiedObject | Object that can be set to aid in development. |