Dmps3SipDialerInit Property

Set SIP configuration parameters.

Namespace: Crestron.SimplSharpPro.DeviceSupport
Assembly: SimplSharpPro (in SimplSharpPro.dll) Version: 2.21.121
Syntax
C#
public StringInputSig Init { get; }

Property Value

StringInputSig
Remarks
Each field must be separated by the & symbol, with no spaces between fields. FIELDS: USER = The local dialing extension of the touch screen. AUTH = The server login username. PW = The server login password. SIPSRV = The server IP address (xxx.xxx.xxx.xxx). SIPPORT = The server port number in decimal. DOMAIN = The server domain. REALM = The server realm. MODE = The panel mode, i.e., SERVER or PEER AUTO = The panel auto function mode, i.e., NONE or DS. RCONFIG = The path of the configuration file to download, for use with the AUTO mode setting. DNAME = The display name of the touch screen. PORT = The port number that the local SIP client will use. SRVNAME = The display name of the SIP server (for information only). PAGE = The paging group the touch screen belongs to. Multiple group names must be separated by commas with no spaces: Example: OUTSIDE,PATIO. PROXYIP = IP address of a proxy server, or NONE to clear. NAMESRV = IP address of an SIP name server, or NONE to clear. STUNDOM = IP address of a STUN Domain server, or NONE to clear. STUNIP = IP address of a STUN server, or NONE to clear. SPSTR =The extra string to include in the SIP INVITE. DND = The Do not Disturb feature preset, i.e. On or Off

Version Information

.NET

Supported in: 6.0

.NET Compact Framework

Supported in: 3.5