Basic |
The BasicShadeSettings type exposes the following members.
| Name | Description | |
|---|---|---|
| FindingLimits |
Sig to indicate that the Open Limit and Close Limit values are being found for a drape.
The ShadeSettingsPropertyChange event will trigger with FindingLimitsEventId. 'true' = finding limits; 'false' = not finding limits | |
| LowerLimit | Moves the shade or drape in the close direction. This signal is equivalent to "CLOSE" while in Upper Limit Setup Mode or Lower Limit Setup Mode. | |
| LowerLimitSet |
Sig to indicate that the shade's lower limit or the drape's close limit has been set.
The ShadeSettingsPropertyChange event will trigger with LowerLimitSetEventId. | |
| ParameterUseMinimalRcb | If set to 1, the device will send only one estimated RCB during the start of any motion. Default value is 0. Values from 0 to 65535 are valid. For CSM-QMTDC-163-1-SG and CSM-QMTDC-163-3-SG-RC this parameter is not supported. | |
| PositionKnown |
Sig to indicate if the position is known for a drape.
The ShadeSettingsPropertyChange event will trigger with PositionKnownEventId. 'true' = position known; 'false' = position unknown | |
| RaiseIsClockwise |
Property to indicate the direction the motor will rotate to open the shade or drape. Default is CounterClockWise (false).
The ShadeSettingsPropertyChange event will trigger with RaiseIsClockWiseEventId. 'true' = the raise/open direction is clockwise; 'false' = the raise/open direction is counter clockwise | |
| RaiseLimit | Moves the shade or drape in the open direction. This signal is equivalent to "OPEN" while in Upper Limit Setup Mode or Lower Limit Setup Mode. | |
| UpperLimitSet |
Sig to indicate that the shade's upper limit or the drape's open limit has been set.
The ShadeSettingsPropertyChange event will trigger with UpperLimitSetEventId. |