Clc |
public class ClcDimLoad : BasicDimmingLoad
The ClcDimLoad type exposes the following members.
| Name | Description | |
|---|---|---|
| CycleDim |
Toggles between a raise and lower operation as follows:
If load is Off or at the Min level, the load will raise.
If load is at the Max level, the load will lower.
At any other level, the load will change in the opposite direction of the last ramp (see raise/lower descriptions).
(Inherited from LDimmingLoad) | |
| DelayedOffFeedback |
Indicates that a local or slave button press has triggered a delayed fade of the lights to full off.
This property is not supported by ZumNetJBoxDaliGroups and ZumLinkExp16ADimu.
(Inherited from BasicDimmingLoad) | |
| DeviceLoadIsOn |
Property to Get the lighting device this load is on.
(Inherited from DimmingLoad) | |
| FastFullOnFeedback |
Indicates that a local or slave button press has triggered a fast fade of the lights to full on.
This property is not supported by ZumNetJBoxDaliGroups and ZumLinkExp16ADimu.
(Inherited from BasicDimmingLoad) | |
| IsFullOnFeedback |
Indicates that the load is currently at the max level defined by the DimmerMaxLevel parameter.
(Inherited from BasicDimmingLoad) | |
| IsOn |
Indicates that the load is on at any level.
(Inherited from LDimmingLoad) | |
| Level |
Property to set the level of the load.
(Inherited from DimmingLoad) | |
| LevelFeedback |
Property to get the level of the load when it changes due to a local buttons press, or a input such as Raise or Lower.
This will not change in response to a value being set by the Level property.
(Inherited from DimmingLoad) | |
| Lower |
Smoothly lowers the light level from its current level to the min level for as long as the property is set 'true'. The ramping operation continues until the light reaches the min level or until the property is set 'false'.
(Inherited from LDimmingLoad) | |
| LowerFeedback |
Indicates that the light level is being lowered due to a local or slave button press.
This property is not supported by ZumLinkJBox16ALv, ZumNetJBox16ALv, ZumLinkExp16ADimu
and ZumNetJBoxDaliGroups.
(Inherited from BasicDimmingLoad) | |
| Number |
Number of this load.
(Inherited from DimmingLoad) | |
| OffFeedback |
Indicates that the lights have faded to full off (0%) due to a local or slave button press.
This property is not supported by ZumNetJBoxDaliGroups and ZumLinkExp16ADimu.
(Inherited from BasicDimmingLoad) | |
| ParameterPresetDefault | Sets the default preset level of the corresponding dimmer. This level will be active at startup and whenever the Reset function (on the Dimmer Controls slot) is triggered. Valid values range from 0% (which will set the level to the Crestron-defined default value) to 100%. Use PercentToUshort(Single) to convert the percentage to a ushort value or UshortToPercent(UInt16) to convert the ushort value to percentage. | |
| Parent |
The parent that a this load is added to.
(Inherited from LightLoad) | |
| Presets |
Collection of the presets available on this load.
This property is not supported by "ClsC6", "ClsC6M", Horizon dimmers, "ZumNetJBoxDaliGroups" and all ZUM devices with loads.
(Inherited from DimmingLoad) | |
| Raise |
Smoothly raises the light level from its current level to 100% (max level) for as long as the property is set 'true'. The ramping operation continues until the light reaches 100% (max level) or until the property is set 'false'.
(Inherited from LDimmingLoad) | |
| RaiseFeedback |
Indicates that the light level is being raised due to a local or slave button press.
This property is not supported by ZumLinkJBox16ALv, ZumNetJBox16ALv,
ZumLinkExp16ADimu and ZumNetJBoxDaliGroups.
(Inherited from BasicDimmingLoad) | |
| Type |
Type of load this object represents.
(Inherited from DimmingLoad) | |
| UserSpecifiedObject |
Object holder for any use by the programmer.
(Inherited from LightLoad) |
| Name | Description | |
|---|---|---|
| CurrentPresetRecalled |
Indicates that the specified preset has been recalled due to a local or slave button press.
(Inherited from BasicDimmingLoad) | |
| DelayedOff |
Trigger a delayed fade of the lights to full off.
This property is not supported by ZumNetJBoxDaliGroups and ZumLinkExp16ADimu.
(Inherited from BasicDimmingLoad) | |
| Equals | Determines whether the specified object is equal to the current object. (Inherited from Object) | |
| FastFullOff |
The light level will ramp from its current level to 0% in 0.25s.
(Inherited from BasicDimmingLoad) | |
| FastFullOn |
The light level will ramp from its current level to the max level in 0.25s.
(Inherited from BasicDimmingLoad) | |
| Finalize | Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object) | |
| FullOff |
Method to set the level to zero.
This method is not supported by "ClsC6" and "ClsC6M" devices.
(Inherited from DimmingLoad) | |
| FullOn |
Method to set the level to maximum.
This method is not supported by "ClsC6" and "ClsC6M" devices.
(Inherited from DimmingLoad) | |
| GetHashCode | Serves as the default hash function. (Inherited from Object) | |
| GetType | Gets the Type of the current instance. (Inherited from Object) | |
| MemberwiseClone | Creates a shallow copy of the current Object. (Inherited from Object) | |
| PresetLoadIsAt |
Indicates that the load is at the corresponding preset level.
(Inherited from BasicDimmingLoad) | |
| ToString |
String representation of this light load.
(Inherited from LightLoad) |
| Name | Description | |
|---|---|---|
| PresetChange |
Event to indicate when preset information is received from the load.
This event is not supported by "ClsC6" and "ClsC6M", Horizon dimmers, "ZumNetJBoxDaliGroups" all ZUM devices with loads.
(Inherited from DimmingLoad) |
| Name | Description | |
|---|---|---|
| _DeviceForThisLoad |
Internal reference to the actual device this load is on.
(Inherited from BasicDimmingLoad) |