Glxp |
This class will trigger BaseEvent, LoadStateChange and OverrideEventHandler events.
public sealed class GlxpSw10 : GlxxSw
The GlxpSw10 type exposes the following members.
| Name | Description | |
|---|---|---|
| GlxpSw10(UInt32, CrestronControlSystem) | Constructor for the GLXP-SW10 device. | |
| GlxpSw10(UInt32, IDeviceBranch) | Constructor for the GLXP-SW10 device. |
| Name | Description | |
|---|---|---|
| ConnectedIpList |
A property containing the list of the ConnectedIpInformation objects which contain information about the devices that are connected to this IP ID.
This property is only valid for an ethernet device. If this is not an ethernet device, then this property will return null.
If this is an ethernet device, the list will be non-null. It will be empty if no devices are connected.
The order of items in this list is not guaranteed.
(Inherited from GenericDevice) | |
| Description |
Get/Set the description of this device.
(Inherited from GenericBase) | |
| Disposed |
Property to indicate if the device has been disposed.
(Inherited from GenericDevice) | |
| ID |
Property to get the ID of the device.
(Inherited from GenericDevice) | |
| InExternalOverrideFeedback |
Indicates if the device is in external override mode
(Inherited from SwitchBaseWithOverride) | |
| InManualOverrideFeedback |
Indicates if the device is in manual override mode
(Inherited from SwitchBaseWithOverride) | |
| IsOnline |
Property to get the current online state of the device.
(Inherited from GenericDevice) | |
| Name |
Get the name of this device.
(Inherited from GenericBase) | |
| NoAcPowerFeedback |
Property to indicate that AC power is not available at the L (line) input of Circuit 1.
This property is not supported by GLXP-CTRL device.
The BaseEvent event will trigger with NoAcPowerFeedbackEventId. (Inherited from GlxxSw) | |
| ParameterOverrideControl |
Parameter to specify the manner in which the override state is saved to non-volatile memory
(Inherited from SwitchBaseWithOverrideControlParameter) | |
| Parent |
The parent that a given object was added to.
(Inherited from GenericBase) | |
| ProductIdFeedback |
Property to report the device's Product ID. Internal use only.
The BaseEvent event will trigger with ProductIdFeedbackEventId. (Inherited from GlxxSw) | |
| Registerable |
Property to indicate that this device can be registered.
(Inherited from GenericDevice) | |
| Registered |
Property to get the current registration state of the device.
(Inherited from GenericDevice) | |
| RegistrationFailureReason |
Property to get the Registration Failure Reason, this will match the return value from the call to register.
(Inherited from GenericDevice) | |
| SIMPLDeviceImplementation |
Internal protected member used for actual device control.
(Inherited from GenericDevice) | |
| SwitchedLoads |
Collection of the switched loads for this device.
(Inherited from SwitchBaseWithOverrideControlParameter) | |
| Type |
Property to determine to type of device this is.
(Inherited from GenericDevice) | |
| UnRegistrationFailureReason |
Property to get the Unregistration Failure Reason, this will match the return value from the call to unregister.
(Inherited from GenericDevice) | |
| UserSpecifiedObject |
Can be assigned anything that user wants.
(Inherited from GenericBase) | |
| XioEndpointStubSIMPLDevice |
The SIMPL "stub" Device that the XiO Director creates for an endpoint to send the 1C/0E to the
correct place in hierarchy.
(Inherited from GenericDevice) |
| Name | Description | |
|---|---|---|
| Dispose |
Clean up of resources.
(Inherited from GenericBase) | |
| Dispose(Boolean) |
Method to perform the actual disposing of the device.
(Inherited from GenericDevice) | |
| EnterManualOverride |
Enter manual override mode
(Inherited from SwitchBaseWithOverride) | |
| Equals | Determines whether the specified object is equal to the current object. (Inherited from Object) | |
| ExitManualOverride |
Exit manual override mode
(Inherited from SwitchBaseWithOverride) | |
| Finalize |
Destructor of the device.
(Inherited from GenericDevice) | |
| GetHashCode | Serves as the default hash function. (Inherited from Object) | |
| GetType | Gets the Type of the current instance. (Inherited from Object) | |
| OnBaseEvent(Int32) |
Protected member used to fire the BaseEvent with the default extended information.
(Inherited from GenericBase) | |
| OnBaseEvent(Int32, UInt16) |
Protected member used to fine the BaseEvent with extended event information.
(Inherited from GenericBase) | |
| OnLoadStateChange |
Method to fire the LoadStateChange event.
(Inherited from LightingBase) | |
| OnOverrideEventHandler |
Method to fire the OverrideHandler event
(Inherited from SwitchBaseWithOverride) | |
| Register |
Register this device with the system.
(Inherited from GenericDevice) | |
| SendParameters |
This will send the parameters fields (if any) to the device. It allows the parameters to be modified and resent without unregistering and re-registering
a device. It requires firmware support on the device.
Not Currently implemented. This will throw a NotSupportedException
(Inherited from LightingBase) | |
| SetInternalParameterDevice |
Device which has the actual parameter
(Inherited from SwitchBaseWithOverrideControlParameter) | |
| ToString |
Return the name of the device.
(Inherited from GenericDevice) | |
| UnRegister |
Unregister this device with the system. This function can not be called from the device's own SigChange event handler.
On successful unregistration, if this device supports the OnlineStatusChange event, it will trigger indicating the device when offline. (Inherited from GenericDevice) |
| Name | Description | |
|---|---|---|
| BaseEvent |
Generic base event, triggered when the there are no other handlers available
for a specific EventID.
(Inherited from GenericBase) | |
| IpInformationChange |
Event that tells what IP Address is connected/disconnected from an IP ID for a non-UDP device.
This is only valid for an Ethernet device. An exception will be thrown if it is not.
(Inherited from GenericDevice) | |
| LoadStateChange |
Event triggered when information from a load is received.
EventIds for this event are located in the LoadEventIds class.
(Inherited from LightingBase) | |
| OnlineStatusChange |
Event triggered when the Online status of the device changes.
(Inherited from GenericDevice) | |
| OverrideEventHandler |
Override event handler
(Inherited from SwitchBaseWithOverride) |
| Name | Description | |
|---|---|---|
| _SwitchedLoads |
Collection of switched loads.
(Inherited from Switch) | |
| _SwitchedSpecificLoads |
Collection of switched loads.
(Inherited from SwitchBaseWithOverrideControlParameter) |