Click or drag to resize

CsaPws10sHubEventIds Fields

The CsaPws10sHubEventIds type exposes the following members.

Fields
 NameDescription
Public fieldStatic memberChannelFailFeedbackEventId The state of ChannelFailFeedback on a segment has changed.

The SegmentStateChange event will trigger for this event id. The Index member will contain the actual channel number (1 or 2) that has changed state. Channel 1 is the left connector, Channel 2 is the right connector on the segment.

Public fieldStatic memberChannelPowerUsageFeedbackEventId The state of PowerUsageFeedback on a segment has changed.

The SegmentStateChange event will trigger for this event id. The Index member will contain the actual channel number (1 or 2) that has changed state. Channel 1 is the left connector, Channel 2 is the right connector on the segment.

Public fieldStatic memberHubStatusFeedbackEventId The hub's status feedback has changed.

This Event Id will trigger on the BaseEvent. The state can be read with the HubStatusFeedback property.

Public fieldStatic memberInTestModeFeedbackEventId The hub's test mode feedback has changed.

This Event Id will trigger on the BaseEvent. The state can be read with the InTestModeFeedback property.

Public fieldStatic memberOverTemperatureFeedbackEventId The hub's over temperature feedback has changed.

This Event Id will trigger on the BaseEvent. The state can be read with the OverTemperatureFeedback property.

Public fieldStatic memberPowerSupplyErrorStatusFeedbackEventId The power supply error status has changed.

This Event Id will trigger on the BaseEvent. The state can be read with the PowerSupplyErrorStatusFeedback property.

Public fieldStatic memberSegmentDisabledFeedbackEventId The disabled state of a hub segment has changed.

If this Event Id triggers on the SegmentStateChange, that means it is for one of the hub segments A-E (1-5) and can be read with the DisabledFeedback property.

If this event Id triggers on the BaseEvent, that means it is for the Master segment and can be read with the MasterSegmentDisableFeedback property.

Public fieldStatic memberSegmentFrameErrorFeedbackEventId A frame error has occurred on a segment.

If this Event Id triggers on the SegmentStateChange, that means it is for one of the hub segments A-E (1-5) and can be read with the FrameErrorFeedback property.

If this event Id triggers on the BaseEvent, that means it is for the Master segment and can be read with the MasterSegmentFrameErrorFeedback property.

Public fieldStatic memberSegmentStatusFeedbackEventId The status of a segment has changed.

If this Event Id triggers on the SegmentStateChange, that means it is for one of the hub segments A-E (1-5) and can be read with the StatusFeedback property.

If this event Id triggers on the BaseEvent, that means it is for the Master segment and can be read with the MasterSegmentStatusFeedback property.

Public fieldStatic memberSegmentTestDoneFeedbackEventId The hub's segment test done feedback has changed.

This Event Id will trigger on the BaseEvent. The state can be read with the SegmentTestDoneFeedback property.

Public fieldStatic memberTestResultsFeedbackEventId The hub's test results feedback has changed.

This Event Id will trigger on the BaseEvent. The state can be read with the TestResultsFeedback property.

Top
See Also