Clw |
The ClwSwExSwitchRemoteButtonSettings type exposes the following members.
| Name | Description | |
|---|---|---|
| ParameterRemoteDoubleTapTime | The time between the end of the first tap and the start of the second tap for a double tap to be recognized. Valid values range from 0.20 to 1.00 seconds. Use the SimplSharpDeviceHelper.SecondsToUShort to convert the time to a ushort value or the SimplSharpDeviceHelper.UShortToSeconds to convert the ushort value to seconds | |
| ParameterRemoteHoldTime | The time that a button must be held before it is recognized as a "Hold" instead of a "Tap". Valid values range from 0.20 to 1.00 seconds. Use the SimplSharpDeviceHelper.SecondsToUShort to convert the time to a ushort value or the SimplSharpDeviceHelper.UShortToSeconds to convert the ushort value to seconds | |
| ParameterRemoteWaitForDoubleTap | Determines whether a "Tap" should be sent immediately on the release of the button, or if the unit should wait until a Double Tap event occurs | |
| ParameterReservedButtonForLocalMode | Specifies which button is reserved to operate in Local mode when the unit is set to Remote mode. Zero = None and One through the number of supported buttons specifies the buttons. |