Din1Tstat8ControlChannel Properties

The Din1Tstat8Din1Tstat8ControlChannel type exposes the following members.

Properties
 NameDescription
Public propertyErrorFeedback Property to indicate if any error with DIN-1TSTAT8, error feedback value for this channel : 0 = No Error; 1 = No Data; 2 = Invalid.

The BaseEvent event will trigger with ErrorFeedbackEventId and Index gives the index into the Channel collection.

Public propertyIsHeatingFeedback Property to indicate a call for heat is active on this channel. True = Heating is active; False = Heating is not active.

The BaseEvent event will trigger with IsHeatingFeedbackEventId and Index gives the index into the Channel collection.

Public propertyModeHeatFeedback Property to indicate that heating mode is enabled for this channel. True = Heat mode is enabled; False = Heat mode is not enabled.

The BaseEvent event will trigger with ModeHeatFeedbackEventId and Index gives the index into the Channel collection.

Public propertyModeOffFeedback Property to indicate the heat mode is off for this channel. True = Heat Mode is off; False = Heat Mode is not off.

The BaseEvent event will trigger with ModeOffFeedbackEventId and Index gives the index into the Channel collection.

Public propertyNumber Control Channel Number
Public propertyParent The parent that a Din1Tstat8Din1Tstat8ControlChannel object was added to.
Public propertySetPoint Property to set temperature setpoint for this channel -values given in 1/10 of a degree, ex. 101 = 10.1 deg (C or F). Range is from 30 to 320 deg C (86 to 608 deg F).
Public propertySetPointFeedback Property to report the current temperature setpoint value for this channel -values set in 1/10 of a degree, ex. 101 = 10.1 deg (C or F). Range is from 30 to 320 deg C (86 to 608 deg F).

The BaseEvent event will trigger with SetPointFeedbackEventId and Index gives the index into the Channel collection.

Public propertyTemperatureFeedback Property to report the temperature feedback for this channel.

The BaseEvent event will trigger with TemperatureFeedbackEventId and Index gives the index into the Channel collection.

Public propertyTemperatureOffset Property to set the temperature Offset for this channel. This affects the temperature regulation and the changes are reflected on the TemperatureFeedback. Valid values are positive or negative given in 1/10 (10th) of a degree in the chosen device units (Celsius or Fahrenheit); for example 25 = 2.5° and -25 = -2.5° Valid value range from -3° to +3° for Celsius as the chosen device units and -6° to +6° for Fahrenheit as the chosen device units.
Public propertyUserSpecifiedObject Can be assigned anything that user wants.