Click or drag to resize

PingMonitoringRule Properties

The PingMonitoringRule type exposes the following members.

Properties
 NameDescription
Public propertyFailedPingAttemptsFeedback Property to indicate the number of ping failures. This value will be reset anytime a ping succeeds.

The PingMonitoringRuleChange event of the parent will trigger with FailedPingAttemptsFeedbackEventId.

Public propertyIncludedOutletsBitmask Collection of properties to select which outlets are controlled by this Rule (Least Significant Bit = Outlet1, Most Significant Bit = Outlet16 for item 1 and Least Significant Bit = Outlet17 for item 2 in the collection).
Public propertyIncludedOutletsBitmaskFeedback Collection of properties to report which outlets are controlled by this Rule (Least Significant Bit = Outlet1, Most Significant Bit = Outlet16 for item 1 and Least Significant Bit = Outlet17 for item 2 in the collection).

The PingMonitoringRuleChange event of the parent will trigger with PingIncludedOutletsBitmaskFeedbackEventId.

Public propertyOnOffFeedback Property to indicate that this rule is enabled.

The PingMonitoringRuleChange event of the parent will trigger with PingRuleOnOffFeedbackEventId.

Public propertyPingInterval Property to set the configurable delay between pings.
Public propertyPingIntervalFeedback Property to report the configurable delay between pings.

The PingMonitoringRuleChange event of the parent will trigger with PingIntervalFeedbackEventId.

Public propertyPingMonitoringTimeout Property to set the user configurable ping timeOut. Value between 1-60 seconds.
Public propertyPingMonitoringTimeoutFeedback Property to report the user configurable ping timeOut. Value between 1-60 seconds.

The PingMonitoringRuleChange event of the parent will trigger with PingMonitoringTimeoutFeedbackEventId.

Public propertyPingRetries Property to set the user configurable number of continuous ping failures to trigger power cycle.
Public propertyPingRetriesFeedback Property to report the user configurable number of continuous ping failures to trigger power cycle.

The PingMonitoringRuleChange event of the parent will trigger with PingRetriesFeedbackEventId.

Public propertyPowerUpWaitTime Property to set the user configurable wait time in minutes before executing Ping test once the specific outlet is power cycled [ note: prevent the device going into infinite power cycle loop].
Public propertyPowerUpWaitTimeFeedback Property to report the current user configurable wait time in minutes before executing Ping test once the specific outlet is power cycled.

The PingMonitoringRuleChange event of the parent will trigger with PingPowerUpWaitTimeFeedbackEventId.

Public propertyRebootAttempts Property to set the user configurable count for number of times the device will auto-reboot.
Public propertyRebootAttemptsFeedback Property to report the user configurable count for number of times the device will auto-reboot.

The PingMonitoringRuleChange event of the parent will trigger with PingRebootAttemptsFeedbackEventId.

Public propertyTarget Collection of properties to set the hostname or IP address of device to ping.
Public propertyTargetFeedback Collection of properties to report the hostname or IP address of device to ping.

The PingMonitoringRuleChange event of the parent will trigger with TargetFeedbackEventId.

Public propertyUserSpecifiedObject Object that can be set to aid in development.
Top