Click or drag to resize

DinAnalogOutput Class

Class to define a DIN Analog Output used by the SimplSharpPro.Lighting.Din.DinAo8 device.
Inheritance Hierarchy
SystemObject
  Crestron.SimplSharpPro.Lighting.DinDinLoadBaseClass
    Crestron.SimplSharpPro.Lighting.DinDinAnalogOutput

Namespace: Crestron.SimplSharpPro.Lighting.Din
Assembly: Crestron.SimplSharpPro.DeviceSupport (in Crestron.SimplSharpPro.DeviceSupport.dll) Version: 2.21.121
Syntax
C#
public class DinAnalogOutput : DinLoadBaseClass

The DinAnalogOutput type exposes the following members.

Properties
 NameDescription
Public propertyLevelIn Property to set the level of the load for a dimmable load. Valid values range from 0% (Off) to 100%. The value is the percentage of the overall range defined by the corresponding MinLevel and MaxLevel. For non-dimmable loads, this property turns the load on or off.A value of 0% turns the load Off; any value above 0% turns the load On(It is recommended to use 100% for On.) Use PercentToUshort(Single) to convert the percentage to a ushort value or UshortToPercent(UInt16) to convert the ushort value to percentage
(Inherited from DinLoadBaseClass)
Public propertyLevelOut Reports the unscaled level of the load. This does not change in response to a value being sent by the LevelIn input. For this reason, the LevelIn should be set to LevelOut from the event handler. In this way, one sig will control the light and always accurately reflect the current light level on the dimmer.
(Inherited from DinLoadBaseClass)
Public propertyMaxLevel Property to set the maximum level of the load Valid values range from 55% to 100%. Out of range values will clamp the min level to 55%. Use PercentToUshort(Single) to convert the percentage to a ushort value or UshortToPercent(UInt16) to convert the ushort value to percentage
(Inherited from DinLoadBaseClass)
Public propertyMinLevel Property to set the minimum level of the load. Valid values range from 0% to 45%. Out of range values will clamp the min level to 45%. Use PercentToUshort(Single) to convert the percentage to a ushort value or UshortToPercent(UInt16) to convert the ushort value to percentage
(Inherited from DinLoadBaseClass)
Public propertyNumber Returns the Load number
(Inherited from DinLoadBaseClass)
Public propertyParameterOverrideLevel Parameter to set the load level to recall in the event the unit enters override. Valid values range from 0% to 100%, which is the percentage of the overall range defined by the corresponding MinLevel and MaxLevel inputs. For non-dimmed loads, 0% signifies Off and any value above 0% signifies On. Default is 100%. Use PercentToUshort(Single) to convert the percentage to a ushort value or UshortToPercent(UInt16) to convert the ushort value to percentage
(Inherited from DinLoadBaseClass)
Top
Methods
 NameDescription
Public methodEqualsDetermines whether the specified object is equal to the current object.
(Inherited from Object)
Protected methodFinalizeAllows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection.
(Inherited from Object)
Public methodGetHashCodeServes as the default hash function.
(Inherited from Object)
Public methodGetTypeGets the Type of the current instance.
(Inherited from Object)
Protected methodMemberwiseCloneCreates a shallow copy of the current Object.
(Inherited from Object)
Public methodToStringReturns a string that represents the current object.
(Inherited from Object)
Top

Version Information

.NET

Supported in: 6.0

.NET Compact Framework

Supported in: 3.5
See Also