Click or drag to resize

HttB10ExLeftBargraph Property

Property to get the left bar graph analog value that will be displayed on the corresponding LED indicators in bargraph format.

The Left bargraph is formed by the LEDs on the left side of the unit; the Right bargraph, by the LEDs on the right side.

ParameterBargraphTimeout parameter shall specify the amount of time a bargraph is displayed. A value of 0 shall indicate no timeout such that indicators shall always function in bargraph mode.

The LEDs will display the ramping value as it changes, and then remain in bargraph mode for the additional period given by the ParameterBargraphTimeout parameter.

If no change occurs to the analog value before the ParameterBargraphTimeout expires, the LEDs revert to standard behavior.

The 5-segment bargraph displays the analog values as follows:

  • Segment 1 (top) LED is ON when analog value = 100%.
  • Segment 2 LED is ON when analog value > 75%.
  • Segment 3 LED is ON when analog value > 50%.
  • Segment 4 LED is ON when analog value > 25%.
  • Segment 5 (bottom) LED is ON when analog value > 0%.

Namespace: Crestron.SimplSharpPro.Keypads
Assembly: Crestron.SimplSharpPro.Keypads (in Crestron.SimplSharpPro.Keypads.dll) Version: 2.21.121
Syntax
C#
public UShortInputSig LeftBargraph { get; }

Property Value

UShortInputSig

Version Information

.NET

Supported in: 6.0

.NET Compact Framework

Supported in: 3.5
See Also