Hz |
The HzKpex type exposes the following members.
| Name | Description | |
|---|---|---|
| BacklightLedSettings |
Backlight LED Settings present on this device.
This property will trigger BaseEvent with event IDs defined in HzKpBase. | |
| Button |
Collection of buttons supported by the device.
(Inherited from KeypadBase) | |
| ConnectedIpList |
A property containing the list of the ConnectedIpInformation objects which contain information about the devices that are connected to this IP ID.
This property is only valid for an ethernet device. If this is not an ethernet device, then this property will return null.
If this is an ethernet device, the list will be non-null. It will be empty if no devices are connected.
The order of items in this list is not guaranteed.
(Inherited from GenericDevice) | |
| DefeatLocalAuxButtonLogic | When this property is set 'false', the device will control the slave output line wire to another dimmer or switch. If set to 'true', the device will operate the button only as a remote logic (send button state information only). If the ParameterLocalAuxButton is to None, this property has no effect. | |
| Description |
Get/Set the description of this device.
(Inherited from GenericBase) | |
| Disposed |
Property to indicate if the device has been disposed.
(Inherited from GenericDevice) | |
| Feedbacks |
Property to get the collection of feedbacks with on and active indicators on HzKpBase.
(Inherited from HzKpBase) | |
| ID |
Property to get the ID of the device.
(Inherited from GenericDevice) | |
| IsOnline |
Property to get the current online state of the device.
(Inherited from GenericDevice) | |
| LedBacklightEnabledFeedback |
Property to indicate the current LED Backlight status set by the EnableLedBacklight or DisableLedBacklight methods.
true = LEDs enabled, false = LEDs disabled
This property will trigger BaseEvent with event id LedBacklightEnabledEventId. (Inherited from HzKpBase) | |
| Name |
Get the name of this device.
(Inherited from GenericBase) | |
| ParameterActiveFeedbackBlinkRate |
Parameter to define the fade blink rate time between the LED On color and LED Off color.
Value in seconds (units of 0.01 sec precision) for the blink/fade period of the LEDs when they are in active feedback state.
Valid range is from 0.1 to 2 seconds. 1 second is represented as 100.
Default value is 0.75 seconds.
Use the SecondsToUshort(Single) to convert
the seconds to a ushort value or the UshortToSeconds(UInt16) to convert
the ushort value to seconds.
(Inherited from HzKpBase) | |
| ParameterAlternateColorTheme | Parameter to select the color theme that is applied to the particular Button Feedback as set by the corresponding ButtonAlternateFeedback (true = Use Alternate Color Theme; false = Use Local Color Theme). If Custom is chosen, then the corresponding RedOrHue, GreenOrSaturation and BlueOrValue properties will get processed instead of preset internal color themes that match much of the defined 'local' color themes. Refer HzKpBaseeLedAlternateColorTheme enum for valid values. | |
| ParameterCustomColorInputType |
Selects whether the properties in LedDayOnSettings/
LedDayOffSettings/
LedNightOnSettings/
LedNightOffSettings are to be processed as RGB (Red/Green/Blue) or HSV (Hue/Saturation/Value) component values.
Refer HzKpBaseeCustomColorInputType enum for valid values.
(Inherited from HzKpBase) | |
| ParameterDayNightThresholdSetting |
Indicates which internal setting to use when device is automatically configured to switch between day and
night mode based on sensor reading. Default (0) indicates it uses either the factory default threshold
setting or the manually calibrated setting if it was saved at least once. Other preset selections are
estimated values based on a typical room brightness setting.
Valid values are from 0 to 5.
Refer HzKpBaseeDayNightThresholdSetting enum for valid values.
(Inherited from HzKpBase) | |
| ParameterDoubleTapSpeed |
Returns and sets the time between the end of the first tap and the start of the second tap for a
"DoubleTap" to be recognized.
Use the SecondsToUshort(Single) to convert
the seconds to a ushort value or the UshortToSeconds(UInt16) to convert
the ushort value to seconds.
Valid range is from 0.2 seconds to 1.0 seconds. 1 second is represented as 100.
(Inherited from HzKpBase) | |
| ParameterFakeFeedback |
Parameter to set and get the Fake Feedback state.
When set to true, the LED corresponding to button will fade blink between On LED color and Off LED color
at the ParameterActiveFeedbackBlinkRate time, for a minimum of 2 sec, until the
State or Active property value is initialized to
some other state.
(Inherited from HzKpBase) | |
| ParameterHoldTime |
Time value in seconds. A press longer than this value triggers a Hold event. A press shorter than this
value triggers a Tap or DoubleTap event.
Use the SecondsToUshort(Single) to convert
the seconds to a ushort value or the UshortToSeconds(UInt16) to convert
the ushort value to seconds.
Valid range is from 0.2 seconds to 1.0 seconds. 1 second is represented as 100.
(Inherited from HzKpBase) | |
| ParameterIsLargeRockerButtonInstalled |
Returns and sets the setting that tells the keypad if a large rocker button is installed
false – LEDs on row 2 and 4 are enabled
true – LEDs on row 2 and 4 are disabled
This parameter requires device firmware version 2.000.0050 or greater (Inherited from HzKpBase) | |
| ParameterLocalAuxButton | Parameter to specify which button combination/mode this keypad is set to. | |
| ParameterLocalButtonActiveFeedback |
Parameter to define the behavior of the LED(s) when a local button is pressed to turn on or off a load. LED(s) can either flash, enable, or do nothing, disable. The timing of the blink is set by ParameterActiveFeedbackBlinkRate.
For quick ramps to the preset level or 100% which take place within a second, the LED will flash at least one transition and end up at on or off state. For a manual raise/lower operation where the button is held down, it will continue to flash while the button is held down, but stop once the ramp is completed and ended at the target level. | |
| ParameterLocalButtonStatusFeedback | Parameter to define what LED(s) are turned on when the load is on (level above zero percent) or off. | |
| ParameterWaitForDoubleTap |
Returns and sets the setting that determines whether a "Tap" should be sent immediately.
false – Tap is reported at the end of every short press, DoubleTap is reported at the end of the second short press.
true – Tap reporting is postponed to see if a second tap comes in. In this case only DoubleTap is reported.
(Inherited from HzKpBase) | |
| Parent |
The parent that a given object was added to.
(Inherited from GenericBase) | |
| Registerable |
Property to indicate that this device can be registered.
(Inherited from GenericDevice) | |
| Registered |
Property to get the current registration state of the device.
(Inherited from GenericDevice) | |
| RegistrationFailureReason |
Property to get the Registration Failure Reason, this will match the return value from the call to register.
(Inherited from GenericDevice) | |
| SIMPLDeviceImplementation |
Internal protected member used for actual device control.
(Inherited from GenericDevice) | |
| Type |
Property to determine to type of device this is.
(Inherited from GenericDevice) | |
| UnRegistrationFailureReason |
Property to get the Unregistration Failure Reason, this will match the return value from the call to unregister.
(Inherited from GenericDevice) | |
| UserSpecifiedObject |
Can be assigned anything that user wants.
(Inherited from GenericBase) | |
| XioEndpointStubSIMPLDevice |
The SIMPL "stub" Device that the XiO Director creates for an endpoint to send the 1C/0E to the
correct place in hierarchy.
(Inherited from GenericDevice) |