Click or drag to resize

DMOutputUSBRoutedTo Property

Selects the input or output where the corresponding USB source (connected to an output slot of the switcher) will be routed. The input has no effect when USB routing is disabled ("USBEnter" = 'false'), or when USB breakaway is disabled ("EnableUSBBreakaway" = 'false'). Valid values are as follows: null = Break connection, valid DMInput or DMOutput object will assign that object.

Namespace: Crestron.SimplSharpPro.DM
Assembly: SimplSharpPro (in SimplSharpPro.dll) Version: 2.21.121
Syntax
C#
public virtual DMInputOutputBase? USBRoutedTo { get; set; }

Property Value

DMInputOutputBase
Example
Example: "switcher.Output[2].USBRoutedTo = switcher.Input[5];" Input 5 of the switcher will be routed to Output 2 of the switcher. "switcher.Output[2].USBRoutedTo = null;" Will Break; the connection on switcher Output2.

Version Information

.NET

Supported in: 6.0

.NET Compact Framework

Supported in: 3.5
See Also