Click or drag to resize

Hz2KpEx Properties

The Hz2KpEx type exposes the following members.

Properties
 NameDescription
Public propertyBacklightLedSettings Property returns the backlight Led settings for version 2.
Public propertyButton Collection of buttons supported by the device.
(Inherited from KeypadBase)
Public propertyConnectedIpList A property containing the list of the ConnectedIpInformation objects which contain information about the devices that are connected to this IP ID. This property is only valid for an ethernet device. If this is not an ethernet device, then this property will return null. If this is an ethernet device, the list will be non-null. It will be empty if no devices are connected. The order of items in this list is not guaranteed.
(Inherited from GenericDevice)
Public propertyDefeatLocalAuxButtonLogic When this property is set 'false', the device will control the slave output line wire to another dimmer or switch. If set to 'true', the device will operate the button only as a remote logic (send button state information only). If the ParameterLocalAuxButton is set to None, this property has no effect.
Public propertyCode exampleDescription Get/Set the description of this device.
(Inherited from GenericBase)
Public propertyDisposed Property to indicate if the device has been disposed.
(Inherited from GenericDevice)
Public propertyFeedbacks Property to get the collection of feedbacks with on and active indicators on HzKpBase.
(Inherited from Hz2KpBase)
Public propertyID Property to get the ID of the device.
(Inherited from GenericDevice)
Public propertyIsOnline Property to get the current online state of the device.
(Inherited from GenericDevice)
Public propertyLedBacklightEnabledFeedback Property to indicate the current LED Backlight status set by the EnableLedBacklight or DisableLedBacklight methods. true = LEDs enabled, false = LEDs disabled

This property will trigger BaseEvent with event id LedBacklightEnabledEventId.


(Inherited from Hz2KpBase)
Public propertyName Get the name of this device.
(Inherited from GenericBase)
Public propertyParameterActiveFeedbackBlinkRate Parameter to define the fade blink rate time between the LED On color and LED Off color. Value in seconds (units of 0.01 sec precision) for the blink/fade period of the LEDs when they are in active feedback state. Valid range is from 0.1 to 2 seconds. 1 second is represented as 100. Default value is 0.75 seconds. Use the SecondsToUshort(Single) to convert the seconds to a ushort value or the UshortToSeconds(UInt16) to convert the ushort value to seconds.
(Inherited from Hz2KpBase)
Public propertyParameterCustomColorInputType Selects whether the properties in LedDayOnSettings/ LedDayOffSettings/ LedNightOnSettings/ LedNightOffSettings are to be processed as RGB (Red/Green/Blue) or HSV (Hue/Saturation/Value) component values. Refer Hz2KpBaseeCustomColorInputType enum for valid values.
(Inherited from Hz2KpBase)
Public propertyParameterDayNightThresholdSetting Indicates which internal setting to use when device is automatically configured to switch between day and night mode based on sensor reading. Default (0) indicates it uses either the factory default threshold setting or the manually calibrated setting if it was saved at least once. Other preset selections are estimated values based on a typical room brightness setting. Valid values are from 0 to 5. Refer Hz2KpBaseeDayNightThresholdSetting enum for valid values.
(Inherited from Hz2KpBase)
Public propertyParameterDoubleTapSpeed Returns and sets the time between the end of the first tap and the start of the second tap for a "DoubleTap" to be recognized. Use the SecondsToUshort(Single) to convert the seconds to a ushort value or the UshortToSeconds(UInt16) to convert the ushort value to seconds. Valid range is from 0.2 seconds to 1.0 seconds. 1 second is represented as 100.
(Inherited from Hz2KpBase)
Public propertyParameterFakeFeedback Parameter to set and get the Fake Feedback state. When set to true, the LED corresponding to button will fade blink between On LED color and Off LED color at the ParameterActiveFeedbackBlinkRate time, for a minimum of 2 sec, until the State or Active property value is initialized to some other state.
(Inherited from Hz2KpBase)
Public propertyParameterHoldTime Time value in seconds. A press longer than this value triggers a Hold event. A press shorter than this value triggers a Tap or DoubleTap event. Use the SecondsToUshort(Single) to convert the seconds to a ushort value or the UshortToSeconds(UInt16) to convert the ushort value to seconds. Valid range is from 0.2 seconds to 1.0 seconds. 1 second is represented as 100.
(Inherited from Hz2KpBase)
Public propertyParameterIsLargeRockerButtonInstalled Returns and sets the setting that tells the keypad if a large rocker button is installed false – LEDs on row 2 and 4 are enabled true – LEDs on row 2 and 4 are disabled
(Inherited from Hz2KpBase)
Public propertyParameterLocalAuxButton Parameter to specify which button combination/mode this keypad is set to.
Public propertyParameterLocalButtonActiveFeedback Parameter to define the behavior of the LED(s) when a local button is pressed to turn on or off a load. LED(s) can either flash, enable, or do nothing, disable. The timing of the blink is set by ParameterActiveFeedbackBlinkRate.

For quick ramps to the preset level or 100% which take place within a second, the LED will flash at least one transition and end up at on or off state. For a manual raise/lower operation where the button is held down, it will continue to flash while the button is held down, but stop once the ramp is completed and ended at the target level.

Public propertyParameterLocalButtonStatusFeedback Parameter to define what LED(s) are turned on when the load is on (level above zero percent) or off.
Public propertyParameterWaitForDoubleTap Returns and sets the setting that determines whether a "Tap" should be sent immediately. false – Tap is reported at the end of every short press, DoubleTap is reported at the end of the second short press. true – Tap reporting is postponed to see if a second tap comes in. In this case only DoubleTap is reported.
(Inherited from Hz2KpBase)
Public propertyParent The parent that a given object was added to.
(Inherited from GenericBase)
Public propertyRegisterable Property to indicate that this device can be registered.
(Inherited from GenericDevice)
Public propertyRegistered Property to get the current registration state of the device.
(Inherited from GenericDevice)
Public propertyRegistrationFailureReason Property to get the Registration Failure Reason, this will match the return value from the call to register.
(Inherited from GenericDevice)
Protected propertySIMPLDeviceImplementation Internal protected member used for actual device control.
(Inherited from GenericDevice)
Public propertyType Property to determine to type of device this is.
(Inherited from GenericDevice)
Public propertyUnRegistrationFailureReason Property to get the Unregistration Failure Reason, this will match the return value from the call to unregister.
(Inherited from GenericDevice)
Public propertyUserSpecifiedObject Can be assigned anything that user wants.
(Inherited from GenericBase)
Protected propertyXioEndpointStubSIMPLDevice The SIMPL "stub" Device that the XiO Director creates for an endpoint to send the 1C/0E to the correct place in hierarchy.
(Inherited from GenericDevice)
Top
See Also