Click or drag to resize

CcsUcCodec300LyncReservedSigs Class

Extender class to provide access to the Lync Meeting Room features of the CcsUcCodec300.

This class will trigger DeviceExtenderSigChange event.

Inheritance Hierarchy
SystemObject
  Crestron.SimplSharpProDeviceExtender
    Crestron.SimplSharpPro.UCCcsUcCodec300LyncReservedSigs

Namespace: Crestron.SimplSharpPro.UC
Assembly: Crestron.SimplSharpPro.UC (in Crestron.SimplSharpPro.UC.dll) Version: 2.21.121
Syntax
C#
public sealed class CcsUcCodec300LyncReservedSigs : DeviceExtender

The CcsUcCodec300LyncReservedSigs type exposes the following members.

Properties
 NameDescription
Protected propertyBooleanInput Bool Inputs on the device extender.
(Inherited from DeviceExtender)
Protected propertyBooleanOutput Bool Outputs on the device extender.
(Inherited from DeviceExtender)
Public propertyCameraPreset Property to set the corresponding camera preset and activates it when changed. Valid values range from 0 to 4.
Public propertyCameraPreset0Feedback Property to indicate that the camera preset0 is selected.

The DeviceExtenderSigChange event will trigger with BoolChange and CameraPreset0Feedback.

Public propertyCameraPreset1Feedback Property to indicate that the camera preset1 is selected.

The DeviceExtenderSigChange event will trigger with BoolChange and CameraPreset1Feedback.

Public propertyCameraPreset2Feedback Property to indicate that the camera preset2 is selected.

The DeviceExtenderSigChange event will trigger with BoolChange and CameraPreset2Feedback.

Public propertyCameraPreset3Feedback Property to indicate that the camera preset3 is selected.

The DeviceExtenderSigChange event will trigger with BoolChange and CameraPreset3Feedback.

Public propertyCameraPreset4Feedback Property to indicate that the camera preset4 is selected.

The DeviceExtenderSigChange event will trigger with BoolChange and CameraPreset4Feedback.

Public propertyCameraPresetFeedback Property to report the current value of "CameraPreset".

The DeviceExtenderSigChange event will trigger with UShortChange and CameraPresetFeedback.

Public propertyHideProjectFeedback Property to indicate if the Smart Graphics project is hidden.

The DeviceExtenderSigChange event will trigger with BoolChange and HideProjectFeedback.

Public propertyShowProjectFeedback Property to indicate if the Smart Graphics project is currently shown/displayed on the system.

The DeviceExtenderSigChange event will trigger with BoolChange and ShowProjectFeedback.

Protected propertyStringInput String Inputs on the device extender.
(Inherited from DeviceExtender)
Protected propertyStringOutput String Outputs on the device extender.
(Inherited from DeviceExtender)
Protected propertyUShortInput UShort Inputs on the device extender.
(Inherited from DeviceExtender)
Protected propertyUShortOutput UShort Outputs on the device extender.
(Inherited from DeviceExtender)
Top
Methods
 NameDescription
Public methodCameraDown Method to move the USB video camera transmitting the video signal leaving the Lync Meeting room in the down direction by one step.
Public methodCameraLeft Method to move the USB video camera transmitting the video signal leaving the Lync Meeting room in the left direction by one step.
Public methodCameraPreset0 Method to set the camera preset0 controlling the PTZ camera connected to the system.
Public methodCameraPreset1 Method to set the camera preset1 controlling the PTZ camera connected to the system.
Public methodCameraPreset2 Method to set the camera preset2 controlling the PTZ camera connected to the system.
Public methodCameraPreset3 Method to set the camera preset3 controlling the PTZ camera connected to the system.
Public methodCameraPreset4 Method to set the camera preset4 controlling the PTZ camera connected to the system.
Public methodCameraRight Method to move the USB video camera transmitting the video signal leaving the Lync Meeting room in the right direction by one step.
Public methodCameraUp Method to move the USB video camera transmitting the video signal leaving the Lync Meeting room in the up direction by one step.
Public methodCameraZoomIn Method to zoom the camera in.
Public methodCameraZoomOut Method to zoom the camera out.
Public methodEqualsDetermines whether the specified object is equal to the current object.
(Inherited from Object)
Public methodGetHashCodeServes as the default hash function.
(Inherited from Object)
Public methodGetTypeGets the Type of the current instance.
(Inherited from Object)
Public methodHideProject Method to hide the Smart Graphics project on the system.
Protected methodInitializeJoins Method to initialize the sigs of the Lync Meeting Room extender.
(Overrides DeviceExtenderInitializeJoins)
Protected methodMapAnalogInputJoins Protected function to map joins to the join collection on the parent device.
(Inherited from DeviceExtender)
Protected methodMapAnalogOutputJoins Protected function to map joins to the join collection on the parent device.
(Inherited from DeviceExtender)
Protected methodMapDigitalInputJoins Protected function to map joins to the join collection on the parent device.
(Inherited from DeviceExtender)
Protected methodMapDigitalOutputJoins Protected function to map joins to the join collection on the parent device.
(Inherited from DeviceExtender)
Protected methodMapSerialInputJoins Protected function to map joins to the join collection on the parent device.
(Inherited from DeviceExtender)
Protected methodMapSerialOutputJoins Protected function to map joins to the join collection on the parent device.
(Inherited from DeviceExtender)
Protected methodSendCueEventDataForDeviceExtender Function to trigger the DeviceExtender Sig Change event
(Inherited from DeviceExtender)
Public methodShowProject Method to show the Smart Graphics project on the system.
Public methodToStringReturns a string that represents the current object.
(Inherited from Object)
Public methodUse Set the extender as usable on the device. Call this method before registration of the device.
(Inherited from DeviceExtender)
Top
Events
 NameDescription
Public eventDeviceExtenderSigChange Event to receive sig information intended for a device extender. When processing this event, it will hold off other sigs from being received from the device. If one desires to continue processing the data and receive more information, launch a new thread and allow this event to exit.
(Inherited from DeviceExtender)
Top
Fields
 NameDescription
Protected field_InUse Bool to determine if the extended is in use by the user.
(Inherited from DeviceExtender)
Top

Version Information

.NET

Supported in: 6.0

.NET Compact Framework

Supported in: 3.5
See Also