Generic TV Wrapper Properties


Device Warm Up Time: Enter value in seconds to specify how long the device needs to warm up. The program logic will wait this amount of time before sending any input commands.

Device Cool Down Time: Enter value in seconds to specify how long the device needs to cool down. The program logic will use this value to prevent power on requests from being sent if the user attempts to turn the device off and on again too quickly.

Power On: Select a command from the Power On drop-down list that will turn the device on. The program logic will send this when a source is selected that has a display input command specified on the Sources tab. Select the device's discrete power commands from the Power On and Power Off lists.

In most cases the standard power on command will be set automatically; however, if Crestron Studio® cannot find a command for a specific device it will be set to (None). You must verify that the correct Power On command is assigned.

Power Off: Select a command from the Power On drop-down list that will turn the device off. The program logic will send this command when the zone turns off.

In most cases the standard power off command will be set automatically; however, if Crestron Studio® cannot find a command for a specific device it will be set to (None). You must verify that the correct Power Off command is assigned.

Volume Up Command: This command is required only when the device is controlling audio in the room.

Volume Down Command: This command is required only when the device is controlling audio in the room.

Volume Mute On/Off Command: This command is required only when the device is controlling audio in the room.

Crestron Studio® will attempt to find the standard Volume Up, Volume Down, and Volume Mute On/Off commands for each source device. If the standard commands cannot be found they will be left unassigned, and you should select the commands manually from the lists.